Control
28
© Lutz-Jesco GmbH 2018
BA-10407-02-V08
Motor-driven diaphragm dosing pump
MEMDOS LB
Operating instructions
9.1.2 AC motors
Connection
Phases
MEMDOS LB
Star connection
PE
CB
Z1
U1
L1
N
Z2
U2
C
C
1 ~
4 - 1010
Delta connection
PE
CB
Z1
U1
L1
N
Z2
U2
C
C
1 ~
4 - 1010
Table 22: Alternating current motor circuit diagrams
9.1.3 Rotational direction of the motor
Fig. 10: Rotational direction arrow on the motor
The arrow indicates the rotational direction of the motor which should be
set-up.
MEMDOS LB
Direction of rotation
4 - 80, 150
Counter -clockwise
110, 160 - 1010
Clockwise
Table 23: Comply with the rotation direction!
9.2 Connection of electric servomotor
Please follow the installation instructions in the operating manual for the
electric servomotor.
10 Control
Stroke length adjustment
The desired delivery rate of the dosing pump is set using the stroke
length adjustment. Turning the adjustment knob adjusts the hub length
and so increases or decreases the amount of dosing media from the dos-
ing head.
The stroke length can be adjusted while the pump is running or while it is
turned off (in depressurized condition).
Fig. 11: Stroke length adjustment
Direction of rotation
Effect
Clockwise
Stroke length is reduced,
delivery rate decreases
Counter -clockwise
Stroke length is raised, delivery
rate increases
Table 24: Stroke length adjustment
The scale on the stroke length adjustment shows the value of the setting
in percentage terms from 0% (stopped) to 100% (maximum possible
stroke length).
%
0
20
40
60
80
100
90
70
50
30
10
1