Operation
Operating modes
46
Solenoid-Diaphragm Dosing Pump
MAGDOS LP
© Lutz-Jesco GmbH 2014
Operating Instructions
BA-10231-02-V03
Interval
The
Interval
batch mode mode offers the following configuration
options:
The system displays the
Interval
with a clock icon and the time
elapsing until the start of next dosing.
Fig. 11-12: Start screen of Interval batch mode mode
Timer
Using the MAGDOS LP dosing pump
Timer
batch mode mode, you can
program two different dosing procedures for a period of one week.
You can provide one or two dosing procedure(s) for each day of the
week which start at a specific time (this start time is repeated for each
further dosing procedure of the same mode on other days of the week).
You can therefore program up to 14 dosing procedures per week. You
must specify for each day of the week if no dosing procedure, dosing
procedure 1, dosing procedure 2, or both dosing procedures should be
started after each other.
Apart from this, you must specify for each dosing procedure whether
the dosing pump is to carry out dosing for a specific time or for a
specific number of strokes.
You can configure the parameters below for dosing procedure 1:
Start time 1
,
Run time 1
,
Preset strokes 1
,
Delivery capacity
(applies to dosing procedures 1 and 2),
Mo-Su
.
You can configure the parameters below for dosing procedure 2:
Start time 2
,
Run time 2
,
Preset strokes 2
,
Delivery capacity
(applies to dosing procedures 1 and 2),
Mo-Su
.
The
Timer
batch mode mode offers the following configuration options:
11.2.4.4 Programming the dosing procedures
1.
Press
Setup
.
The dosing pump displays the current configuration of this oper-
ating mode's parameters (Menu 3.41).
2.
Press
Setup
.
Capacity
Specifies the required stroke frequency stated as
a percentageof the maximum stroke frequency
(see „Delivery capacity data“ on page 12).
Parameter
Explanation
Runtime
Specifies the required runtime of the dosing
pump; input in minutes. The value that is
displayed in brackets indicates the calculated
output.
No. of strokes
Specifies the number of required strokes. The
value that is displayed in brackets indicates the
calculated output.
Capacity
Specifies the required stroke frequency stated as
a percentageof the maximum stroke frequency
(see „Delivery capacity data“ on page 12).
Interval
Specifies the interval at which dosing is to take
place on a regular basis. The interval cannot be
shorter than the specified or calculated runtime;
if necessary, the system corrects it automatically
to the minimum value.
Table 11-7: Interval configuration mode
Parameter
Explanation
Table 11-6: Start/Stop and Ext. Start configuration
Batch mode
Menu
Start
0%
0
Setup
13:59
You must set the date, time and day of the week before
configuring the parameters. For more information, refer to
page 33.
Parameter
Explanation
Start time 1
Specifies the required time for dosing procedure
1.
Start time 2
Specifies the required time for dosing procedure
2.
Runtime 1
Specifies the required run time of dosing proce-
dure 1, stated in minutes. The bracket value in
the display shows the calculated delivery rate
(based on the setting in the
Delivery
capacity
parameter).
Runtime 2
Specifies the required run time of dosing proce-
dure 2, stated in minutes. The bracket value in
the display shows the calculated delivery rate
(based on the setting in the
Delivery
capacity
parameter).
Preset strokes
1
Specifies the required number of strokes of
dosing procedure 1. The value that is displayed
in brackets indicates the calculated output.
Preset strokes
2
Specifies the required number of strokes of
dosing procedure 2. The value that is displayed
in brackets indicates the calculated output.
Capacity
Specifies the required stroke frequency for both
dosing procedures stated as a percentage of the
maximum stroke frequency (see „Delivery
capacity data“ on page 12).
Mo-Su
Specifies the day of the week on which a
specific dosing procedure is to be started.
Table 11-8: Timer configuration mode
i