Solenoid-Diaphragm Dosing Pump
MAGDOS LP
Operating Instructions
BA-10231-02-V03
5.
Press
Back
.
The
Safety code
is activated. You must enter it when accessing
the
System setup
menu.
10.6.11.1 Entering the safety code
Fig. 10-12: Entering the safety code
1.
Use the
+
and
-
keys to set a value of 0 to 9 for the first digit of the
code and then press
Next
.
2.
Proceed as described under point 1 for the other digits.
3.
After entering all the digits, press
OK
.
If your input is correct, the dosing pump displays the
System
setup
menu.
10.6.11.2 Deactivating the safety code
1.
Press
Menu
.
2.
Use the
or
key to choose the
System setup
menu item and
press
OK
.
3.
Enter the correct safety code and press
OK
.
4.
Use the
or
key to choose the
Safety code
menu item and
press
Setup
.
5.
Keep pressing
Next
until
On
is selected.
6.
Press
-
.
7.
Press
Back
.
The safety code is deactivated.
10.6.12 Set "Factory setup" menu item
Resets the dosing pump's control unit settings to the factory default
setting.
1.
Use the
or
key to choose the
Factory setup
menu item and
press
Setup
.
2.
Press
OK
.
The dosing pump displays the
Language
menu (menu 6.3); see
also “Menu settings at initial commissioning” on page 33.
The dosing pump is reset to the factory setup setting.
10.6.13 Set "Eco-Mode" menu item
Setting energy-saving mode. Doing this changes the power consump-
tion, the delivery capacity and the delivery pressure; see also “Technical
Data” on page 12.
1.
Use the
or
key to choose the
Eco-Mode
menu item and press
Setup
.
You can choose from the following options:
Off
(factory default setting),
Eco-Mode 1,
Eco-Mode 2,
2.
Use the
or
key to choose the desired function and press
OK
.
The system displays the selected
Eco-Mode
on the start screen
after the respective operating mode.
Fig. 10-13: Display of Eco-Mode 1 in manual operating mode
10.6.14 Set "User setup" menu item
This menu item allows you to save the settings you made in the
System setup
menu.
10.6.14.1 Saving own settings
1.
Use the
or
key to choose the
User setup
menu item and
press
Setup
.
2.
Use the
or
to choose
Save
and press
OK
.
Own settings saved.
10.6.14.2 Loading own settings
1.
Use the
or
key to choose the
User setup
menu item and
press
Setup
.
2.
Use the
or
to choose
Load
and press
OK
.
Own settings loaded.
10.6.15 Set "IP address" menu item (MAGDOS LP-Net only)
This menu item allows you to set the network address. You local
network administrator specifies the address. It is not possible to set up
a subnet, a proxy or a gateway.
1.
Use the
or
key to choose the
IP address
menu item and
press
Setup
.
2.
Use the
+
and
-
keys to set a value of 001 to 255 for the first digit
of the IP address and then press
Next
.
3.
Proceed as described under point 2 for the other digits of the IP
address.
4.
Press
Back
.
IP address is set.
If you have forgotten the code, please contact Lutz-Jesco
GmbH.
Safety code
1 1 1 1
OK
8.2
Next
-
+
i
Manual mode Eco 1
Menu
Stop
-
+
Liter
h
0%
0.00