4. MEASURING PROCEDURE

4-1 Power on/off

  Button = Power Button

1)

Power on :  

Press " Power Button " once.

2)

Power off : 

During power on, press " Power Button " > 3 seconds.
will power off.

4-2 LCD backlight on/off

During power on, press " Power Button " once, then  the
LCD backlight will be on 5 seconds then off automatically,

4-3 Function selection

The meter can select 2 kind function as :

a.Anemometer 
b.Air flow ( CMM, CFM )

During power on,  press the " Hold button " 
continuously ( not release the button ),  the Display will
show the following text in sequence :

Display

Function

text

 An

Anemometer ( Air velocity ) 

 AirFL

Air flow ( CMM, CFM )

Until the Display show the desired function, just
release the " Hold button " , the meter will execute this
function with default.

4

Содержание SP-82AM

Страница 1: ...r you into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g t e c h n i q...

Страница 2: ...splay 3 3 5 Wristlet 3 3 6 Anemometer Vane 3 3 7 Battery Compartment Cover 3 3 8 Buttons operation label 3 4 MEASURING PROCEDURES 4 4 1 Power on off 4 4 2 LCD backlight on off 4 4 3 Function selection...

Страница 3: ...uracy at high and low air velocity Built in microprocessor circuit assures excellent performance and accuracy Concise and compact buttons arrangement easy operation Memorize the maximum and minimum va...

Страница 4: ...ft min 1 ft min m s 0 4 to 20 0 m s 0 1 m s 20 m s 3 F S km h 1 4 to 72 0 km h 0 1 km h 20 m s 4 F S MPH 0 9 to 44 7 mile h 0 1 MPH knots 0 8 to 38 8 knots 0 1 knots Remark ft min feet per minute MPH...

Страница 5: ...3 FRONT PANEL DESCRIPTION Fig 1 3 1 Hold button 3 2 Button Power button 3 3 REC nutton 3 4 LCD display 3 5 Wristlet 3 6 Anemometer Vane 3 7 Battery Compartment Cover 3 8 Buttons operation label 3...

Страница 6: ...be on 5 seconds then off automatically 4 3 Function selection The meter can select 2 kind function as a Anemometer b Air flow CMM CFM During power on press the Hold button continuously not release th...

Страница 7: ...ection unit for all function are Measurement Unit Air velocity M S Km h mph knot FPM Air flow CMM CFM side it is normal 4 5 Air flow measurement 1 Power on select the function to Air flow measurement...

Страница 8: ...cord and display the maximum and minimum reading values Start the Record function by pressing the REC Button once There will be a REC symbol on the display 2 With the REC symbol on the display a Press...

Страница 9: ...unction just execute the REC function above chapter 4 7 then the Auto power off function will be canceled 5 BATTERY REPLACEMENT 1 When the LCD display shows symbol it is necessary to replace the batte...

Отзывы: