background image

2

Installation Instructions

Occupant Copy

SG-3WD

Status

Indicator

LEDs

SG-2W

Open Button

Close Button

SG-3WRL

Raise/Lower Buttons

SG-3W

Status

Indicator

LEDs

Status

Indicator

LEDs

Open Button

Close Button

Stop Button

Open Button

Close Button

Stop Button

Open Button

Close Button

Stop Button

Status

Indicator

LEDs

Open Button

Close Button

Stop Button

SG-5WRL (Sivoia

®

only)

Raise/Lower Buttons

Status

Indicator

LEDs

Open Button

Close Button

Preset 1, 2, 3 Buttons

Group 1

Group 2

For SG5WRL only:

Presets

- Pressing one of the preset buttons (Preset 1, Preset 2, or

Preset 3) will cause the window  treatments to move to their
programmed preset level.

Note:

Window Treatment Wallstations can only control zones on GRAFIK Eye Control Units with software revision 7-0 or higher. Window
Treatment Wallstations will not function correctly with Control Units with lower software revisions.

Button Functionality

Pressing the Open, Close, or Preset button will cause the window
treatment to move to the selected oosition. Pressing the 

same

Open,

Close, or Preset button a second time while the window treatments
are moving will sto the window treatments.

Open

- Pressing the Open button once will cause the window

treatments to move to the open position.

Close

- Pressing the Close button once will cause the window

treatments to move to the closed position.

Stop

Pressing the Stop button will casue the movement of the

window treatments to stop.

Raise

- Holding the Raise button will cause the window treatments to

move towards the open position. Releasing the Raise button will
cause the window treatments to stop.

Lower

- Holding the Lower button will cause the window treatments

to move towards the closed position. Releasing the Lower button will
cause the window treatments to stop.

030747b  8/28/02  10:12 AM  Page 2

Содержание seeTouch SG-2W

Страница 1: ...LUTRON SG 2W SG 3W SG 3WRL SG 3WD SG 5WRL TM Window Treatment Wallstations for use with 3000 Series and 4000 Series systems 030747b 8 28 02 10 12 AM Page 1 ...

Страница 2: ...ons will not function correctly with Control Units with lower software revisions Button Functionality Pressing the Open Close or Preset button will cause the window treatment to move to the selected oosition Pressing the same Open Close or Preset button a second time while the window treatments are moving will sto the window treatments Open Pressing the Open button once will cause the window treat...

Страница 3: ...Unit by using Class 2 PELV wiring methods per the National Electrical Code Check with your local electrical inspector for the local code requirements and wiring practices allowed in your area Use only a cloth with warm water and mild soap to clean faceplates no chemical cleaners Wiring Notes System Maximums 8 Unique GRAFIK Eye addresses per system 16 Wallstations per system 8 GRAFIK Eye Sivoia Con...

Страница 4: ... Your Wallstation is factory set for the backlight to be On The backlight can be switched on or off by setting DIP switch 10 4 Remove the faceplate adapter if applicable and button assembly from the Wallstation to access DIP switches 1 Turn power Off Proper wiring of Wallstations is dependent upon the GRAFIK Eye Control System that is providing power GRAFIK Eye 3000 Series and GRAFIK Eye 4000 Seri...

Страница 5: ... 4 of the Wallstation s terminal block Shielding must be connected as shown but do not connect to Earth Ground or Wallstation Two 12 AWG 2 5 mm2 power wires will not fit in the terminal blocks however 12 AWG 2 5 mm2 is necessary due to voltage drop on the wire Use the diagram shown at right to make the connections in the wallbox 8 Mount Wallstations as shown below Attach faceplate by pressing in a...

Страница 6: ...r about 3 seconds until the LED s start cycling Note SG 3WD can control 2 separate groups of window treatment zones Only ONE 1 set of button controls can be in setup mode at a time Press and hold here for setup mode LEDs cycle Press and hold here for setup mode Press and hold here for setup mode SG 2W SG 3W SG 3WRL LEDs cycle LEDs cycle Press and hold here for setup mode Press and hold here for se...

Страница 7: ... setup mode Press and hold the buttons indicated in Step 1 for about 3 seconds until the scene LEDs stop cycling 2 Identify the Control Unit s to be controlled by the Wallstation All Units must be addressed To add an individual window treatment zone from a Control Unit Press the ZONE button for the window treatment zone to be controlled by the Wallstation The entire column of LEDs of this zone wil...

Страница 8: ...ate to state Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you These products may be covered under one or more of the following U S patents 4 835 343 4 924 349 DES 422 567 DES 436 ...

Отзывы: