R
S p e c i f i c at i o n S u b m i t ta l
page
Job Name:
Job Number:
Model Numbers:
QS System
QSE-IO
Control Interface
369374a 9 08.07.12
QSE-IO Operating Modes and DIP Switch Settings Overview (continued)
Mode
Dip Switch
Contact Closures Invoke:
Configuration
3
4
5
6
7
8 Input 1
Input 2
Input 3
Input 4
Input 5
Inputs
Outputs
Partitioning
(momentary)
Wall 1
Wall 2
Wall 3
Wall 4
Wall 5
Momentary
Maintained
Partitioning
(maintained)
Wall 1
Wall 2
Wall 3
Wall 4
Wall 5
Maintained
Maintained
Occupancy sensor
(auto on/off)
Generates events on occupancy and vacancy
Maintained
Maintained
Occupancy sensor
(manual on/auto off)
Generates events on vacancy only
Maintained
Maintained
Zone toggle
(maintained)
Toggle 1
Toggle 2
Toggle 3
Toggle 4
Toggle 5
Maintained
Maintained
Zone toggle
(momentary)
Toggle 1
Toggle 2
Toggle 3
Toggle 4
Toggle 5
Momentary
Zone toggle with raise/lower
(maintained)
Toggle 1
Toggle 2
Toggle 3
Raise
Lower
Maintained
Zone toggle with raise/lower
(momentary)
Toggle 1
Toggle 2
Toggle 3
Raise
Lower
Momentary
Zone control
(maintained output)
Toggle 1
Toggle 2
Toggle 3
Toggle 4
Toggle 5
Maintained
Maintained
Toggle 1
Toggle 2
Toggle 3
Toggle 4
Toggle 5
Momentary
Zone control
(momentary output)
Pulse 1
Pulse 2
Pulse 3
Pulse 4
Pulse 5
Maintained
Momentary
Pulse 1
Pulse 2
Pulse 3
Pulse 4
Pulse 5
Momentary
Zone control
(pulsed output)
Pulse 1
Pulse 2
Pulse 3
Pulse 4
Pulse 5
Maintained
Pulsed
Pulse 1
Pulse 2
Pulse 3
Pulse 4
Pulse 5
Momentary
Hotel configuration 1
Service
(make up
room)
Privacy
(do not
disturb)
Doorbell
Start/end
afterhours
mode
Toggle
Scene 1/
Off
1-3:
Maintained or
Momentary
4-5:
Maintained
Maintained
(except 3)
Hotel configuration 2
Service
(make up
room)
Privacy
(do not
disturb)
Doorbell
Start/end
afterhours
mode
Enable/
disable
Scene
lockout
1-3:
Maintained or
Momentary
4-5:
Maintained
Maintained
(except 3)
Integration configuration
Control
output 1
Control
output 2
Control
output 3
Control
output 4
Control
output 5
Maintained or
Momentary
Maintained or
Momentary
Notes
• Occupancy sensor: Each input represents 1 sensor/group of sensors. Response to sensor event is programmable at the assigned lighting
control.
• “Momentary” output pulse is of fixed duration (250 ms default).
“Pulsed” output duration corresponds to activating button being held/released.
• Hotel: “Service” and “Privacy” are mutually exclusive; “Doorbell” is locked out when “Privacy” is active.
• DIP switch 1 must be up/on to activate the "Start/End Afterhours" feature on CCI4.
• DIP switch 2 must be up/on to activate the "Toggle Scene" or "Scene Blackout" feature on CCI 5.
• Occupancy sensors will not participate in partitioning logic.
Legend:
Up/On
Down/Off
s c e n e
s e l e c t i o n
s p e c i a l a n d
s p e c i a l 2
z o n e
t o g g l e
z o n e
c o n t r o l
h o t e l
c o n fi g u r a t i o n
i n t e g r a t i o n
c o n fi g u r a t i o n
s h a d e
s t u f f s
p a r t i t i o n i n g
o c c s e n s o r
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8
3
4
5
6
7
8