5. AUTO POWER OFF DISABLE

The instrument has built-in " Auto Power Shut-off " in
order to prolong battery life. The meter will switch off
automatically if none of the buttons are pressed within 10
min.
To de-activate this feature, Select the memory record
function during measurement, by pressing the " MAX./MIN.
Button " ( 3-5, Fig. 1 ).

6. RS232 PC SERIAL INTERFACE

The instrument features an RS232 output via 3.5 mm
Terminal ( 3-9, Fig. 1 ).
The connector output is a 16 digit data stream which

can be utilized to the user's specific application.

An RS232 lead with the following connection will
be required to link the instrument with the PC
serial input.

Meter

PC

(3.5 mm jack plug)

(9W 'D" Connector)

Center Pin.................................. Pin 2

 Ground/shield................................Pin 5

7

Содержание PM-9102

Страница 1: ...u into the field of precision measurement Although this MANOMETER is a complex and delicate instrument its durable structure will allow many years of use if proper operating techniques are developed P...

Страница 2: ...splay 4 3 2 Power Off On Button 4 3 3 Hold Button 4 3 4 Zero Button 4 3 5 MAX MIN Button 4 3 6 Unit Button 4 3 7 P1 input socket 4 3 8 P2 input socket 4 3 9 RS 232 Output Terminal 4 3 10 Battery Compa...

Страница 3: ...nel easy to offset the zero value Microprocessor circuit assures maximum possible accuracy provides special functions and features Super large LCD display with contrast adjustment for best viewing ang...

Страница 4: ...s Data output RS 232 PC serial interface Sampling time Approx 0 8 second Power off Auto shut off saves battery life or manual off by push button Operating 0 to 50 32 to 122 temperature Operating Less...

Страница 5: ...2 inch 0 05 inch Atmosphere 0 197 Atmosphere 0 001 Atmosphere Unit Max range Accuracy mbar 200 mbar 2 F S psi 2 9 psi 0 204 Note mm Hg 150 mm Hg 23 5 inch Hg 5 905 inch Hg F S full scale meter 2 040...

Страница 6: ...1 3 1 Display 3 7 P1 input socket 3 2 Power Off On Button 3 8 P2 input socket 3 3 Hold Button 3 9 RS 232 Output 3 4 Zero Button Terminal 3 5 MAX MIN Button 3 10 Battery Compartment 3 6 Unit Button Co...

Страница 7: ...et P1 input socket P2 input socket for accepting the differential pressure input Connecting the pipe along the Plug 3 11 Fig 1 to a P1 input socket 3 7 Fig 1 only b P2 input socket 3 8 Fig 1 only c Bo...

Страница 8: ...ar on the display b Press the MAX MIN Button again the Min symbol along with the minimum value will appear on the display c To exit the memory record function press the MAX MIN Button continuously for...

Страница 9: ...on during measurement by pressing the MAX MIN Button 3 5 Fig 1 6 RS232 PC SERIAL INTERFACE The instrument features an RS232 output via 3 5 mm Terminal 3 9 Fig 1 The connector output is a 16 digit data...

Страница 10: ...o D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D0 End Word RS232 FORMAT 9600 N 8 1 Baud rate 9600 Parity No parity Data bit no 8 Data bits Stop...