Lutron Electronics PM-1063SD Скачать руководство пользователя страница 20

8. Saving data from the SD card

    to the computer ( EXCEL software )

1) After execute the Data Logger function, take away the

SD card out from the " SD card socket " ( 3-9, Fig. 1 ).

2) Plug in the SD card into the Computer's SD card slot

( if your computer build in this installation ) or 

insert the SD card into the " SD card adapter ". then 

connect the " SD card adapter " into the computer.

3) Power ON the computer and run the " EXCEL software ".

Down load the saving data file ( for example the file

name :  PAA01001.XLS, PAA01002.XLS ) from the SD

card to the computer. The saving data will present into

the EXCEL software screen ( for example as following

EXCEL data screens ) , then user can use those EXCEL

data to make the further Data or Graphic analysis

usefully.

18

Содержание PM-1063SD

Страница 1: ...f this AIR QUALITY MONITOR with SD CARD DATA RECORDER marks a step forward for you into the field of precision measurement Although this Meter is a complex and delicate instrument its durable structur...

Страница 2: ...10 6 4 ALARM function 11 6 5 User calibration function 11 7 DATALOGGER 14 7 1 Preparation before execute datalogger function 14 7 2 Auto Datalogger Set sampling time 2 second 15 7 3 Manual Datalogger...

Страница 3: ...m Humidity 5 to 95 RH Temperature 0 to 50 PM2 5 time weighted average reading Data hold Record Max Min ALARM setting there is beeper sound output and external device control output Health index 0 9 d...

Страница 4: ...l point Datalogger Auto 2 sec to 3600 sec Sampling Time Setting range Manual Push the data logger button once will save data one time Set the sampling time to 0 second Manual mode can also select the...

Страница 5: ...age 24 V DC Maximum starting current 70mA DC Power Supply DC 1 5 V UM3 AA x 6 PCs or equivalent AC to DC 9 V power adapter Power Current DC 122 mA approximately Backlight ON approximately DC 142 mA Op...

Страница 6: ...er PM2 5 Range 0 to 250 g m Resolution 1 g m Accuracy 10 reading 15 g m Humidity Humidity Range 5 to 95 R H Resolution 0 1 R H Accuracy 70 RH 3 reading 1 RH 70 RH 3 RH Temperature Temperature Range 0...

Страница 7: ...OLD key button 3 11 ALARM socket 3 4 REC key button 3 12 RS232 socket 3 5 TIME SET key button 3 13 DC 9V power adapter socket 3 6 ENTER LOG key button 3 14 PM2 5 Air sampling inlet Air filter net 3 7...

Страница 8: ...function Back to measurement mode 4 3 3 REC KEY 3 4 Fig 1 The maximum and minimum record 4 3 4 TIME SET KEY 3 5 Fig 1 A In the measurement screen press the button will display the year month day and t...

Страница 9: ...Auto Power Off Setting SET BEEP Beeper sound ON OFF setting SET DEC SD Card Decimal character setting USA or EURO SET T C F Temp Unit setting SET ALARM Upper and lower alarm value setting SET PM2 5 Ho...

Страница 10: ...ET KEY proceed to the next function setting SET P OFF SET BEEP 4 5 5 SET BEEP Beeper sound ON OFF setting A Press or KEY to select YES or NO when you select YES press ENTER KEY function is to store th...

Страница 11: ...C Escape setting Press the TIME SET KEY once you leave the setting screen 5 Measurement procedure 5 1 METER POWER ON Press POWER KEY 2 SEC When you Into the the boot screen about 5 SEC After you Into...

Страница 12: ...g SCREEN1 6 2 Data Record 6 2 1 Press REC KEY once the screen will appear REC symbol at the same time begin PM2 5 RH and Temp maximum and minimum data processing eg SCREEN9 6 2 2 Press REC KEY once th...

Страница 13: ...alue 5 B High ALARM status Measured value upper limit set value Hysteresis value the Alarm goes OFF C Low ALARM status Measured value lower limit value Hysteresis value the Alarm goes OFF D Example PM...

Страница 14: ...the value press ENTER KEY store then back to the first layer PM calibration screen eg SCREEN17 then press TIME SET KEY proceeds RH screen eg SCREEN20 6 5 3 RH calibration In SCREEN20 screen press ENTE...

Страница 15: ...SCREEN1 SCREEN2 SCREEN3 SCREEN4 SCREEN5 SCREEN6 SCREEN7 SCREEN8 SCREEN9 SCREEN10 SCREEN11 SCREEN12 SCREEN13 SCREEN14 SCREEN15 SCREEN16 SCREEN17 SCREEN18 SCREEN19 SCREEN20 SCREEN21 SCREEN22 SCREEN23 13...

Страница 16: ...It recommend strongly do not use memory cards that have been formatted by other meter or by a computer Reformat the memory card with your meter c Time setting If the meter is used at first time it sh...

Страница 17: ...set the beeper sound is enable refer to Chapter 4 5 5 page 8 b Pause the datalogger During execute the Datalogger function if press the Logger Button 3 6 Fig 1 once will pause the Datalogger function...

Страница 18: ...position no eg SCREEN14 It can use the Button 3 7 Fig 1 or Button 3 8 Fig 1 to set the measuring Location no 1 to 99 for example room 1 to room 99 to identify the measurement location the Display wil...

Страница 19: ...new file name PAA01 XLS After exist the Datalogger then execute again the data will save to the PAA01 XLS until Data column reach to 30 000 columns then will generate a new file for example PAAXX001...

Страница 20: ...or insert the SD card into the SD card adapter then connect the SD card adapter into the computer 3 Power ON the computer and run the EXCEL software Down load the saving data file for example the fil...

Страница 21: ...19...

Страница 22: ...r decries to zero the Replace Filter Information will be remove 10 POWER SUPPLY from DC ADAPTER The meter also can supply the power supply from the DC 9V Power Adapter Insert the plug of Power Adapter...

Страница 23: ...Reset Button 3 10 Fig 1 once a while will reset the circuit system 13 RS232 PC SERIAL INTERFACE The instrument has RS232 PC serial interface via a 3 5 mm terminal 3 12 Fig 1 The data output is a 16 di...

Страница 24: ...RH data 2 When send the Temp data 3 D12 D11 Annunciator for Display g m 3 H0 RH 04 01 02 D10 Polarity 0 Positive 1 Negative D9 Decimal Point DP position from right to the left 0 No DP 1 1 DP 2 2 DP 3...

Страница 25: ...aches heart respiratory tract and cough or have a sore cardiovascular vessel disease should throat etc should reduce the physical demands consider reducing the especially reduce the outdoor sports out...

Страница 26: ...is in this range the eyes nose will have some the excitement Will have phenomenon obviously worsened to the Very sensitive ethnicity reduce its ability of movement Unhealthful General masses look at t...

Страница 27: ...PATENT The meter SD card structure already get patent or patent pending in following countries Germany Nr 20 2008 016 337 4 JAPAN 3151214 CHINA ZL 2008 2 0189918 5 ZL 2008 2 0189917 0 25 160601 PM1063...

Отзывы: