Maestro

R

 Dual-Circuit Occupancy Sensing Switch Programmable Features

The Sensing Switch has many features to allow you to set the unit to meet your individual needs. The following is an 

overview of all the product features.

Explanation of Sensing Switch Features

Timeout:

 

The approximate time (in minutes) after which the lights will go out after the last motion is detected. The 

Timeout can be adjusted to 1, 5, 15, or 30 minutes. Typically, a shorter Timeout should be used in a smaller room or a 

location where the duration of stay is short. Conversely, a longer Timeout should be used in a larger room or a location 

where the duration of stay is long. The default Timeout is 15 minutes.

What do I want?

The ideal Timeout for an application may vary depending on the size of the room in which the unit is installed. The position 

of the sensor in relation to activity as well as the typical duration of stay will influence your desired Timeout setting.

 

The longer you plan on occupying a room, the longer the value the Timeout should be set. For most conference rooms 

and offices, a Timeout of no less than 5 minutes is advised, to ensure the desired light level is maintained throughout 

occupancy of the space.
In applications where the Sensing Switch is controlling fluorescent or CFL bulbs, a Timeout of no less than 15 minutes is 

recommended to maintain bulb life.

Sensor Mode: 

The automatic functionality of the sensor can be adjusted to control how the lights respond upon initial 

occupancy. There are two available Sensor Modes: Auto-ON/Auto-OFF (Occupancy Mode), and Manual-ON/Auto-OFF 

(Vacancy Mode)

 

Auto-ON / Auto-OFF (Occupancy Mode): 

The lights will always turn on when occupancy is detected. 

  

Manual Off (Exit Time Delay): 

After the unit is manually turned off, the Auto-ON feature will be disabled for 25 seconds, even if motion is 

detected. This is to provide occupants time to exit larger rooms after manually turning the lights off. The unit can be manually turned on at any 
time. After 25 seconds, the unit will return to normal operation.

 

Manual-ON / Auto-OFF (Vacancy Mode): 

This setting converts the sensor to vacancy mode. The lights will not 

automatically turn on but will still automatically turn off after vacancy. The lights must be manually turned on by 

pressing the desired Tap button on the Sensing Switch.

What do I want?

    If you want the lights to automatically turn on when someone enters the room, the sensor mode should be set to "Auto-

ON / Auto-OFF (Occupancy mode)." 

    If you prefer that the lights only turn on when the Tap button is pressed, choose Manual-ON / Auto-OFF (Vacancy 

Mode). The unit will only turn off automatically, when occupancy is no longer detected. Bedrooms are a typical 

application where Manual-ON mode would work better than Auto-ON mode for most users.

Содержание Maestro MS-OPS6-DDV

Страница 1: ...ch spec submittal P N 369748 at www lutron com occvacsensor Dual Circuit Occupancy Sensing Switch shown without faceplate Circuit 1 Tap Button Circuit 2 Tap Button Top Programming Button Bottom Programming Button Glossary Page 2 Explanation of Sensing Switch Features Page 3 Sensing Switch Coverage Area Page 6 Sensing Switch Programming Page 7 Additional Programming Options Page 9 Restoring Default...

Страница 2: ...g Manual ON Auto OFF Vacancy Mode This is the default setting for Circuit 2 of your sensor The Sensing Switch will only turn on when the Tap button is pressed but will still turn off automatically when you vacate the room This setting is also known as Vacancy mode Off While Occupied OWO Disabled The sensor automatically turns on when you enter the room and turns off when you vacate the room When i...

Страница 3: ...olling fluorescent or CFL bulbs a Timeout of no less than 15 minutes is recommended to maintain bulb life Sensor Mode The automatic functionality of the sensor can be adjusted to control how the lights respond upon initial occupancy There are two available Sensor Modes Auto ON Auto OFF Occupancy Mode and Manual ON Auto OFF Vacancy Mode Auto ON Auto OFF Occupancy Mode The lights will always turn on...

Страница 4: ...n the lights off and have them stay off while the room is occupied i e conference room presentations movies etc then Off While Occupied Enabled OWO should be kept as your Advanced Auto ON Mode It is also likely that your Timeout for this application should be greater than 5 minutes to increase the chances of maintaining an occupied status in situations where movement is minimal If you want the lig...

Страница 5: ...ion What Do I Want If you have a Partial ON MS PPS6 DDV XX Sensing Switch and you would like your lighting zones to be swapped from their current configuration this is an ideal solution to avoid re wiring the unit You can switch your Occupancy Auto ON Auto OFF zone with your Vacancy Manual ON Auto OFF zone to get the desired setting for your application If you have an Occupancy MS OPS6 DDV XX Sens...

Страница 6: ... 25 ft 7 5 m 30 ft 9 m 30 ft 9 m Vertical Beam Diagram 0 10 ft 3 m 15 ft 4 5 m 20 ft 6 m 25 ft 7 5 m 30 ft 9 m 4 ft 1 2 m NEMA WD7 Test Grid Coverage High Sensitivity Setting 5 ft 1 5 m 5 ft 1 5 m 0 10 ft 3 m 10 ft 3 m 15 ft 4 5 m 15 ft 4 5 m 5 ft 1 5 m Major motion coverage 900 ft 81 m Minor motion coverage 400 ft 36 m 0 5 ft 1 5 m 10 ft 3 m 15 ft 4 5 m 20 ft 6 m 25 ft 7 5 m 30 ft 9 m 0 ...

Страница 7: ...ay on for as long as motion is detected The lens will flash periodically indicating that motion has been detected Timeout Total number of flashes 1 Test Mode Test Mode 2 1 minute 1 minute 3 5 minutes 5 minutes 4 15 minutes 15 minutes 5 30 minutes 30 minutes Circuit 1 Circuit 2 Selecting a Sensor Mode 1 Hold the programming button that corresponds with the appropriate circuit top programming button...

Страница 8: ...al number of flashes 1 Low 2 High 3 Restore ALL settings to default Dual Circuit Sensing Switch Programming continued Selecting Advanced Auto ON Mode 1 Hold both programming buttons 2 Count the number of times the lens flashes and release both buttons after the desired setting has been selected Note This setting will apply to ALL circuits set to Auto ON Auto OFF Occupancy mode and will not apply t...

Страница 9: ...ped Zone Mapping Total number of flashes 1 Default Circuit Mapping 2 Swapped Circuit Mapping Restoring Default Settings The Sensing Switch has the ability to be returned to its original factory settings This ability allows the programmer a risk free experience to try multiple setting styles without worry Note The default settings are Circuit 1 Timeout 15 minutes Circuit 2 Timeout 15 minutes Circui...

Страница 10: ...ounded Blacka Green Bare Black Orange Neutral Load 1 Load 2 120 277 V Black Black Orange Groundb A Single Line Wiring B Two Line Wiring Blacka Green Groundb Bare Black Orange Neutral 2 Line 1 Load 1 Load 2 Line 2 120 277 V Neutral 1 Black Black Orange 120 277 V 2 Connect dual circuit Sensing Switch WARNING Shock Hazard May result in serious injury or death Turn power OFF at circuit breaker s befor...

Страница 11: ...ocess 1 You enter the room the lights stay off and you decide you want the lights ON there is not enough ambient light in the space for you 2 You press the Tap button within 5 seconds of entering room 3 The unit has learned your preference for when lights should turn on and adjusted its threshold accordingly If I press a button AFTER 5 seconds of being in a room will my unit learn that preference ...

Страница 12: ... from any interaction with any Auto ON Auto OFF Occupancy circuit within the first 5 seconds of entering a room I believe I m using ALD correctly in my Dual Circuit product but I m still not getting the response I expect What could be happening Please make sure that the button s you press when you enter the room correspond to a circuit set to Auto ON Auto OFF Occupancy mode The sensor will NOT lea...

Страница 13: ... directions on how to wire your product Lights turn back ON after they are manually turned OFF Advanced Auto ON Mode Off While Occupied Disabled has been selected The lights will continue to turn back on 25 seconds after the lights are manually turned off if the space is still occupied Use the instruction sheet s Custom Settings instructions to change your Advanced Auto ON Mode to Off While Occupi...

Страница 14: ...l South America 1 610 282 6701 EUROPEAN HEADQUARTERS United Kingdom Lutron EA Ltd 6 Sovereign Close London E1W 3JF United Kingdom TEL 44 0 20 7702 0657 FAX 44 0 20 7480 6899 FREEPHONE UK 0800 282 107 Technical Support 44 0 20 7680 4481 lutronlondon lutron com ASIAN HEADQUARTERS Singapore Lutron GL Ltd 15 Hoe Chiang Road 07 03 Tower 15 Singapore 089316 TEL 65 6220 4666 FAX 65 6220 4333 Technical Su...

Отзывы: