1
1. FEATURES
* 5000 g measuring capacity with 1 g resolution.
* RS 232 PC serial interface.
* Full capacity tare function capability.
* Only one control button on front panel, easy operation.
* Battery or DC adapter power supply.
* Large LCD display.
* Stainless platform.
* Durable & portable housing plastic case.
* LOAD CELL transducer, high precision.
* Gram and Oz display unit, select by rear switch.
* Use exclusive microprocessor LSI-circuit, high reliability.
2. SPECIFICATIONS
Display
20.9 mm(0.8") LCD, 5 digits w/annunciator.
Measuring Capacity
5000 g/176 oz.
Resolution
1 g/0.05 oz.
Min. Display Weight
3 g/0.15 oz.
Accuracy
±( 0.3 % + 1 d ).
* 23±5
℃
.
* Spec. tested under the environment RF
Field Strength less than 3 V/M &
frequency less than the 30 MHz only.
Unit Select
g or oz, select by internal slide switch.
Sampling Time
Approx. 0.5 second.
Tare Control
Full capacity.
Transducer
Load cell.
Circuit
Exclusive LSI-circuit.
Data Bus
RS-232 serial output.
Cabinet Size
250 x 190 x 70 mm
Platform Size
185 x 185 mm.
Operating Temp.
0 to 50
℃
( 32 to 122
℉
).
Operating Humidity
Less than 80% RH.
Weight
1542 g/ 3.4 LB.
* not include batteries.
Power Supply
6 x 1.5V AA (UM-3) BATTERY,
or DC 9V adapter.