background image

99.99 W x 0.01 W, 520.0 W x 0.1 W 

Power factor, ACV, ACA

WATT METER

Model : DW-6063

Your purchase of this
WATT METER marks a
step forward for you
into the field of
precision measurement.
Although this METER is
a complex and delicate
instrument, its durable
structure will allow
many years of use if
p r o p e r   o p e r a t i n g
t e c h n i q u e s   a r e
developed. Please read
t h e   f o l l o w i n g
instructions carefully
and always keep this
manual within easy
reach.

       OPERATION MANUAL

Содержание DW-6063

Страница 1: ...into the field of precision measurement Although this METER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g t e c h n i q u e...

Страница 2: ...oltage current to the input terminal Remove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories III 260V P...

Страница 3: ...RCE terminal 4 3 8 RS 232 output terminal 4 3 9 DC 9V Power Adapter input socket 4 3 10 Battery Cover Compartment 4 3 11 Stand 4 4 MEASUREING PROCEDURES 5 4 1 Power ON OFF 5 4 2 ACV measurement proced...

Страница 4: ...True RMS measurement of ACV ACA Super large LCD Dual display at same time Full function Auto range Memory Record Max Min Data Hold RS232 USB Computer interface Built in low battery indicator Built in...

Страница 5: ...et the USB plug Operation 0 to 50 32 to 122 Temperature Operation Less than 80 RH Humidity Power Supply Alkaline or Heavy duty type DC 9V battery 006P MN1604 PP3 or equivalent Power Approx DC 10 mA Co...

Страница 6: ...0 1 mA 0 3 0 3 mA ACA 2 A 1 mA 0 3 3 mA Auto range ACV ACA accuracy is test under input signal is sine wave 50 60 Hz ACV ACA frequency response is from 40 to 400 Hz Max input value AC voltage 260V AC...

Страница 7: ...y 3 2 POWER Backlight button 3 3 FUNCTION button 3 4 HOLD button 3 5 RECORD button MAX MIN 3 6 LOAD terminal 3 7 POWER SOURCE terminal 3 8 RS 232 output terminal 3 9 DC 9V Power Adapter input socket 3...

Страница 8: ...use the test lead measurement unknown AC voltage 5 Read the up display The value indicated corresponds to the position selected If the Display shows it indicates an Out of range measurement 4 3 ACA m...

Страница 9: ...nt power switch Let it work then you can read out the POWER CONSUMPTION from the bottom of the LCD display value 9 At the same time Push the FUNCTION button 3 3 Fig 1 once then change function for mea...

Страница 10: ...e the memory function continuously c To exit the memory record function just press the REC button for 2 seconds at least The display will revert to the current reading 4 7 Backlight ON OFF 1 When use...

Страница 11: ...d periodically 4 Do not leave the instrument exposed to direct heat from the sun for long periods 5 Before removing the battery compartment cover ensure that the instrument is disconnect from any circ...

Страница 12: ...h digit indicates the following status D0 End Word D1 D8 Display reading D1 LSD D8 MSD For example If the display reading is 1234 then D8 to D1 is 00001234 D9 Decimal Point DP position from right to t...

Страница 13: ...display show it is necessary to replace the battery However in spec measurement may still be made for several hours after LOW BATTERY INDICATOR appears before the instrument become inaccurate 2 Open...

Отзывы: