2. SPECIFICATIONS

2-1 General Specifications

Green power

* Green power, battery is no need,

and

power supply from the handy

Hybrid power

generator, operate 10 to 20
seconds the generator will offer 
10 minutes energy typically.

* Hybrid power, meter also can

supply by the battery power.

Display              

46 mm x 45 mm large LCD display.

Measurement 

ACV, ACA, DCV, DCA, ohms,
continuity beeper, Hz, Capacitance,
Diode, Data hold.

A/D counts no.

6000 counts.

Range selection

Smart function, auto range or
manual range  selecting.

Smart function

" V " function can select ACV, DCV
automatically with auto range.

 " function can select the

Resistance,  Diode, Continuity
beeper, Capacitance automatically
with auto range.
" 10A " " mA " function can measure
ACA, DCA with auto range.

Data hold

To freeze the display reading on the 
LCD display.

* Available for auto range only.

Power On/Off

If meter is not operated within 3

management

minutes will auto power switch off.

Polarity             

Automatic Switching, " - " indicates
negative polarity.

Sampling time

Approx. 0.5 to 1 second.

Operating

0  to 50   (32 to 122  ).

Temperature

2

Содержание DM-9983G

Страница 1: ...the field of precision measurement A l t h o u g h t h i s MULTIMETER is a complex and delicate instrument its durable structure will allow many years of use if p r o p e r o p e r a t i n g techniqu...

Страница 2: ...emove test leads before open the battery cover Cleaning Only use the dry cloth to clean the plastic case Environment Conditions Installation Categories III 600V Pollution Degree 2 Altitude up to 2000...

Страница 3: ...switch G B switch 6 4 POWER TYPE SELECTION 6 MEASURING PROCEDURE 8 5 1 Precautions preparations for measurement 8 5 2 Power management 8 5 3 Symbols Units of Display 9 5 4 Voltage ACV DCV measurement...

Страница 4: ...ge function can select the Resistance Diode Continuity beeper Capacitance automatically with auto range 10A mA function can measure ACA DCA with auto range Data hold auto range Auto shut off is availa...

Страница 5: ...unts Range selection Smart function auto range or manual range selecting Smart function V function can select ACV DCV automatically with auto range function can select the Resistance Diode Continuity...

Страница 6: ...ACA DCA current adapter CA 502 CA 203 CA 501 ACA current adapter CA 201 Pressure adapter PS 403 Light adapter LX 02 EMF adapter EMF 824 Sound level adapter SL 406 High voltage probe HV 40 2 2 Electri...

Страница 7: ...function the ACA start measurement is 10 A range 1 50 A mA range 1 50 mA OHMS auto range Range 600 6 K 60 K 600 K 6 M ohm Resolution 0 1 1 10 100 1 K ohm Accuracy 1 3d Over load protection 350 DCV 350...

Страница 8: ...Diode Short non conductance good defect test Continuity If measuring resistance is less than 10 ohm the beeper will sound 5...

Страница 9: ...3 3 Hold button 3 4 Select button 3 5 Hz button 3 6 Range button 3 7 Function switch 3 8 V terminal 3 9 COM terminal 3 10 mA terminal 3 11 10 A terminal 3 12 Handle of power generator 3 13 Stand 3 14...

Страница 10: ...ousing case LCD display Power generator s handle 2 Lift and extend the Power generator s handle and rotate the handle in clockwise direction will generate the power energy into the meter refer to Fig...

Страница 11: ...Red Black Test Leads into the proper input terminal before making measurement 2 Remove either of the test leads from the circuit when changing the measurement range 3 Do not exceed the maximum rated v...

Страница 12: ...the Data hold function is operated Data hold function is executed on the Automatic range or Manual mode mode Power voltage is already under the low condition Appears when the Continuity beeper is oper...

Страница 13: ...Connect RED test lead into terminal 3 8 Fig 1 3 Select the Function switch 3 7 Fig 1 to the position 4 Power On the meter by pressing the Power On button 3 2 Fig 1 once the Display will show SMART the...

Страница 14: ...7 Fig 1 to position 4 Power On the meter by pressing the Power On button 3 2 Fig 1 once the Display will show SMART the meter is under Smart mode for Diode measurement 5 a When connected with polarity...

Страница 15: ...b above Fig 3 5 7 Capacitance Measurement 1 Connect BLACK test lead into COM terminal 3 9 Fig 1 2 Connect RED test lead into terminal 3 8 Fig 1 3 Select the Function rotary switch 3 7 Fig 1 to the po...

Страница 16: ...g 1 once the Display will show SMART the meter is under Smart mode for AC mA DC mA measurement 5 The meter can measure the AC mA DC mA value automatically and with auto range selection 60 mA 600 mA Th...

Страница 17: ...selection When the Display show the SMART the meter is ready for the Smart mode Under the Smart mode if press the Select button 3 4 Fig 1 once or once in sequence then can select the individual funct...

Страница 18: ...measurement of the measurement signal with auto range indication 5 13 Data Hold 1 During the auto range measurement Display show AUTO indicator if pressing the Hold button 3 3 Fig 1 once will freeze...

Страница 19: ...he Fuse A is broken or not 2 When the 10 A current range can not operation please check if the Fuse B is broken or not 3 When replace the fuse should take the test leads from the measuring circuit and...

Страница 20: ...the batteries should make attention the battery polarity 4 Make sure the battery cover is secured after changing the batteries 7 OPTIONAL ACCESSORIES and ADAPTERS Item Model Carrying Case CA 03 CA 05...

Страница 21: ...9 THE ADDRESS OF AFTER SERVICE CENTER 18 0811 DM9983G...

Отзывы: