Lutron Electronics DM-9030 Скачать руководство пользователя страница 16

2) Loose the Battery Cover Screw (3-7 Fig 1), slide the

battery cover away from the instrument and remove the
battery.

3) Replace with a 9V battery and reinstall the cover.
4) Make sure the battery cover is secured with the screw

after changing battery.

7. OPTIONAL TEMPERATURE PROBE & OTHER

 ACCESSORIES 

Temperature Probe

Measure Range: -40 

to 250 

(Type K) TP-01

    (-40 

to 482 

)

Max. short -term operating 

temperature: 300

(572

)

It is an ultra fast response naked

bead thermocouple suitable for many 

general purpose application.

Temperature Probe

Measure Range:-50 

to 900 

(Type K) TP-02A

   (-50 

to 1700 

)

Dimension: 10cm tube, 3.2mm dia.

Temperature Probe

General purpose application.

Measure Range:-50 

to 500 

(Type K) TP-02B

   (-50 

to 932 

)

Dimension: 10cm tube, 4.2mm dia.

10cm handle.

Temperature Probe

Measure Range:-40 

to 1200 

(Type K) TP-03

   (-40 

to 2200 

)

Dimension: 10cm tube, 8mm dia.

Carry case, CA - 03

Dimension: 185 x 90 x 60mm

(7.3 x 3.5 x 2.4inch)

Weight : 70g (0.1 LB)

Plug, PL - 03

Plug available for measuring external 

transistor hFE

Test Lead, TL - 02A

High quality and better performance

test lead with silicon rubber wire &

alligator clip sets.

Содержание DM-9030

Страница 1: ......

Страница 2: ...minal 1 3 7 Battery compartment 1 4 PRECAUTIONS PREPARATIONS FOR MEASUREMENT 1 5 MEASURING PROCEDURE 5 1 Voltage Measurement 1 5 2 Current Measurement 1 5 3 Resistance Measurement 1 5 4 Temperature Me...

Страница 3: ...tion Do not apply the overload voltage current to the input terminal Remove test leads before open the battery cover Environment Conditions Installation categories II Pollution Degree 2 Altitude up to...

Страница 4: ...e range of automotive electronics tests Duty cycle with Dwell conversion chart for electronic fuel injection and feedback carburetors Diode test quickly measures the forward bias voltage drop of alter...

Страница 5: ...olarity Zero Adjustment Automatic Over input Display shows 1 or 1 Sampling time Approx 0 4 second Operating Temp 0 to 50 32 to 122 Operating Less than 80 RH Humidity Power Approx DC 3 6 mA Consumption...

Страница 6: ......

Страница 7: ...emove either of the test leads from the circuit under test when changing the measurement range 6 Operate the instrument only in the ambient temperature range of 32 122 0 50 and less than 80 relative h...

Страница 8: ...LOW voltage value should under 1 V If not bump engine until it reach d If the above c point voltage display showed lower than 0 2V then the contact resistance of Points is normal or it need to be cha...

Страница 9: ...ground HIGH TENSION WIRE by laying or taping lug to bare metal surface b Connect BLACK TEST PROBE to NEG battery terminal Connect RED TEST PROBE to POS battery terminal c After cranking engine for ab...

Страница 10: ...measured 5 3 Resistance Measurement 1 Connect red test lead to OHM input terminal and black test lead to COM input terminal 2 Determine the highest anticipated resistance 200OHM 2K 20K 200K 2000K or...

Страница 11: ...n device if greatest accuracy is to be achieved This will only take a couple of minutes and only applies if the plug of probe has previously been exposed to an ambient temperature different ot that me...

Страница 12: ...o 3 SPARK PLUG ref Fig 2 then the display will show RPM reading x 10 RPM NOTE a RPM TACH used the Secondary Tech measuring method no matter what cylinder is b If the display reading is unstable it may...

Страница 13: ...minal 3 Connect red test probe into BREAKER POINTS or terminal of IGNITION COIL Connect black test probe into GROUND or terminal of battery The wire connection diagram please ref fig 3 4 Crank engine...

Страница 14: ...nto circuit under test If the resistance value to f the circuit is less than approx 100 OHM then there will be Beeper sound output from the meter A When connected with polarity as shown in Fig 4 a for...

Страница 15: ...ENT PROBE This range is exactly same as DC 2V range but without decimal point It can match the 400 A or 2 000 A range of optional DC AC CURRENT PROBE such as CA 501 CA 202 then can get current values...

Страница 16: ...thermocouple suitable for many general purpose application Temperature Probe Measure Range 50 to 900 Type K TP 02A 50 to 1700 Dimension 10cm tube 3 2mm dia Temperature Probe General purpose applicati...

Страница 17: ...The address of after service center 9610 DM 9030 IEC1010...

Отзывы: