Lutron Electronics DM-9030 Скачать руководство пользователя страница 1

Содержание DM-9030

Страница 1: ......

Страница 2: ...minal 1 3 7 Battery compartment 1 4 PRECAUTIONS PREPARATIONS FOR MEASUREMENT 1 5 MEASURING PROCEDURE 5 1 Voltage Measurement 1 5 2 Current Measurement 1 5 3 Resistance Measurement 1 5 4 Temperature Me...

Страница 3: ...tion Do not apply the overload voltage current to the input terminal Remove test leads before open the battery cover Environment Conditions Installation categories II Pollution Degree 2 Altitude up to...

Страница 4: ...e range of automotive electronics tests Duty cycle with Dwell conversion chart for electronic fuel injection and feedback carburetors Diode test quickly measures the forward bias voltage drop of alter...

Страница 5: ...olarity Zero Adjustment Automatic Over input Display shows 1 or 1 Sampling time Approx 0 4 second Operating Temp 0 to 50 32 to 122 Operating Less than 80 RH Humidity Power Approx DC 3 6 mA Consumption...

Страница 6: ......

Страница 7: ...emove either of the test leads from the circuit under test when changing the measurement range 6 Operate the instrument only in the ambient temperature range of 32 122 0 50 and less than 80 relative h...

Страница 8: ...LOW voltage value should under 1 V If not bump engine until it reach d If the above c point voltage display showed lower than 0 2V then the contact resistance of Points is normal or it need to be cha...

Страница 9: ...ground HIGH TENSION WIRE by laying or taping lug to bare metal surface b Connect BLACK TEST PROBE to NEG battery terminal Connect RED TEST PROBE to POS battery terminal c After cranking engine for ab...

Страница 10: ...measured 5 3 Resistance Measurement 1 Connect red test lead to OHM input terminal and black test lead to COM input terminal 2 Determine the highest anticipated resistance 200OHM 2K 20K 200K 2000K or...

Страница 11: ...n device if greatest accuracy is to be achieved This will only take a couple of minutes and only applies if the plug of probe has previously been exposed to an ambient temperature different ot that me...

Страница 12: ...o 3 SPARK PLUG ref Fig 2 then the display will show RPM reading x 10 RPM NOTE a RPM TACH used the Secondary Tech measuring method no matter what cylinder is b If the display reading is unstable it may...

Страница 13: ...minal 3 Connect red test probe into BREAKER POINTS or terminal of IGNITION COIL Connect black test probe into GROUND or terminal of battery The wire connection diagram please ref fig 3 4 Crank engine...

Страница 14: ...nto circuit under test If the resistance value to f the circuit is less than approx 100 OHM then there will be Beeper sound output from the meter A When connected with polarity as shown in Fig 4 a for...

Страница 15: ...ENT PROBE This range is exactly same as DC 2V range but without decimal point It can match the 400 A or 2 000 A range of optional DC AC CURRENT PROBE such as CA 501 CA 202 then can get current values...

Страница 16: ...thermocouple suitable for many general purpose application Temperature Probe Measure Range 50 to 900 Type K TP 02A 50 to 1700 Dimension 10cm tube 3 2mm dia Temperature Probe General purpose applicati...

Страница 17: ...The address of after service center 9610 DM 9030 IEC1010...