manualshive.com logo in svg
background image

Limited Warranty 

(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)

Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty serv-
ice, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED
TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION,
OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES
NOT COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON’S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR
IN CONNECTION WITH THE MANUFACTURE, SALE,
INSTALLATION, DELIVERY, OR USE OF THE UNIT
SHALL NEVER EXCEED THE PURCHASE PRICE OF
THE UNIT.

This warranty gives you specific legal rights, and you may
have other rights which vary from state to state. Some
states do not allow the exclusion or limitation of inciden-
tal or consequential damages, or limitation on how long
an implied warranty may last, so the above limitations
may not apply to you. 
This product may be covered by the following U.S.
patent: 4,835,343; and corresponding foreign patents.
U.S. and foreign patents pending. Lutron and Claro are
registered trademarks and Dalia is a trademark of
Lutron Electronics Co., Inc. NEC is a registered trade-
mark of the National Fire Protection Association,
Quincy, Massachusetts. 
© 2006 Lutron Electronics Co., Inc.

Each Control Has Inside

Sections Removed

Middle Control Has Two
Side Sections Removed

Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A.
11/06  P/N  030-911-03 Rev. A

English

ON

OFF

ON

OFF

ON

OFF

Backwired:
Insert screw-
driver. Pull wire
out.

Screw Terminals: 
Turn screws to
loosen.

SINGLE-POLE:

Insulated wires connected to
two screws of the same color.
Replace with a SINGLE-POLE
switch. 

See Step 5a when

wiring.

OR

3-WAY:

Insulated wires connected to three screws. One of
these wires is connected to a screw of a different-
color (not green) or labeled COMMON. 

MARK

or

TAG

this wire to identify it when wiring. Replace

with a 3-WAY switch. 

See Step 5b when wiring.

Tag

Different-colored screw
(Common). Actual location may
vary.

OR

Ground (Bare
Copper or
Green Wire)

Ground (Bare Copper
or Green Wire)

1

1

Turning OFF power.

• Turn power OFF at circuit breaker (or remove fuse).

2

2

Removing wallplate and switch.

• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall 

(do not remove wires).

Caution:

Verify power

is OFF to switch
before proceeding.

3

3

Identifying the type of circuit.

4

4

Disconnecting switch wires.

• Carefully disconnect switch wires.

Important Wiring Information

ON

OFF

ON

OFF

ON

OFF

7

7

Turning ON power.

• Turn power ON at circuit breaker (or replace fuse).

6

6

Mounting switch to wallbox.

• Form wires carefully into the wallbox, mount and align switch.
• Install wallplate.

• Connect the 

green

switch ground

wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 3.)

• Connect the 

black 

switch wire to

the wire removed from the differ-
ent-colored screw on the switch
(marked or tagged wire) in Step 3.
Remove tag from wire.

• Connect the 

red

switch wire to

either of the remaining wires
removed from the switch.

• Connect the 

red/white

switch

wire to the remaining wire
removed from the switch.

*See Capacity Chart for details

• Connect the 

green

switch ground

wire to the bare copper or green
ground wire in the wallbox. (See
Important Note 3.)

• Connect one of the 

black

switch

wires to either of the wires
removed from the switch.

• Connect the remaining 

black

switch wire to the other wire
removed from the switch.

*See Capacity Chart for details

5

5

Wiring the Switch.

• For installations involving more than one control in a wallbox, refer to

the section on Multigang Installations before beginning.

• To use a 3-way switch (black, red and red/white wires) in a single-pole

application, cap off the red/white wire and follow instructions for sin-
gle-pole wiring.

5a - Single-Pole Wiring

5b - 3-Way Wiring

Important Notes

Please read before installing.

1. CAUTION:

For control of permanently installed incandescent lamp fixtures and low-voltage trans-

former loads, motor loads, or fluorescent fixtures only. To avoid overheating and possible damage to
other equipment, do not use to control receptacles or transformer-supplied appliances.

2.

Install in accordance with all national and local electrical codes.

3.

When no “grounding means” exist within the wallbox then the NEC

®

2005, Article 404-9 allows a

switch without a grounding connection to be installed as a replacement, as long as a plastic, non-
combustible wallplate is used. For this type of installation, cap or remove the green ground wire on
the switch and use an appropriate wallplate such as Lutron’s 

Claro

®

series wallplates.

4.

For new installations, install a test switch before installing the switch.

5.

Protect switch from dust and dirt when painting or spackling.

6. Clean switch with a 

soft damp cloth only

.

Do not use any chemical cleaners.

Multigang Installations

When installing more than one control in the
same wallbox, it may be necessary to remove
all inner side sections prior to wiring (see dia-
gram). If pre-installed, remove the Lutron
wallplate and wallplate adapter from switch.
Using pliers, bend side section up and down
until it breaks off. Repeat for each side section
to be removed. 

Note:

No derating required if

ganged.

?

Technical Assistance

If you have questions concerning the installation or operation of this product, call the

Lutron Technical Support Center

. Please provide exact model number when calling.

U.S.A. and Canada (24 hrs/7days) 
1-800-523-9466 
Other countries (8am – 8pm ET)
+1-610-282-3800

Fax +1-610-282-6311

http://www.lutron.com

Type of Load

Single-pole or 

3-way with a dimmer

3-way with switch(es)

Lighting

600 W/VA

1000 W/VA

Motor / Fan

1 HP

N/A

Switch Capacity Chart

Attach standard wallplate.

Attach 

Claro

wallplate.

OR

Depending on model number, the
switch may include a Lutron 

Claro

wallplate. If so, please remove the front

piece of the wallplate from the adapter before
installing.

This will expose switch mounting holes

and prevent wallplate damage while installing switch.

Grasp and
pull front
piece of
wallplate
from the
wallplate
adapter.

Green

Ground

Black

Red/White

Red

Tag

Green

Black

Green

Red

Red /
White

Ground

3-Way Switch

3-Way Switch

120 V

~

60 Hz

Neutral

Black

Black

Green

Ground

Load*

120 V

~

60 Hz

Ground

Tag

Lutron Technical Support Center     1-800-523-9466     24 hrs / 7 days     www.lutron.com

Single-Pole Switch

3-Way Switch

DL-1PSL, LX-1PSL

DL-3PSL, LX-3PSL

Rated at 120 V~  60 Hz

1 HP motor/fan
600 W/VA lighting
1000 W/VA when used as 3-way with Lutron dimmer

Do Not Remove

Outside Sections

Neutral

When making wire connections, follow the recom-
mended strip lengths and combinations for the sup-
plied wire connectors. 

Note: 

Wire connectors pro-

vided are suitable for 

copper wire only.

For alu-

minum wire, consult an electrician.

Important Note:

Your wall switch may have two wires attached to the same screw

(see illustrations below for examples). Tape these two wires together before discon-
necting. Connect both wires to the switch wire in Step 5.

One wire in the back-
wired hole and one to
the screw.

One continuous wire
to the screw.

Twist wire connector tight.

Be sure no bare wire is

exposed.

Strip insulation 1/2" (13 mm) for 10, 12 or 14 AWG wire
Strip insulation 5/8" (16 mm) for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply wires
with one 10, 12, 14, 16, or 18 AWG control wire.

Installation

• Easy-to-follow

Instructions

Instructions

faciles à suivre

• Easy-to-follow

Instructions

Instructions

faciles à suivre

030-911-03

030-911-03

Load*