background image

Quick Start Guide

ALD-D48 Enclosure

 Rough-In Installation

For more detailed installation, configuration, programming, and operating 
instructions, refer to the 

ALD-D48

 Instruction Manual available on-line at 

www.amx.com

.

Items in The Box

Optional Accessories

Installation

1.

Mount Rough-In Enclosure using following methods (mounting 
hardware is not provided):

a.   Surface Mount - Use keyholes shown in Figure 1 with bolts 

sufficient for 50 lbs. (9kg) load (1/4" (M6) bolts recommended).

b.   Recess Mount - Use screws through the right side of the panel 

sufficient for 50 lbs. (9 kg) load. Mount panel flush to or not more 
than 1/8" (3mm) below the finished wall surface. Panel is 2-7/8" 
(6.2cm) deep past cover mounting tabs.

Caution:

Suitable for mounting in a vertical position only. Do not mount or place 

the unit in a horizontal where the vent holes in the front are facing up.

This equipment is air-cooled. Mount in a location where the vented 

cover will not be blocked.

Internal relays will click while in use. Mount in a location where such 

noise is acceptable.

All wiring must be in accordance with national and local electrical 

codes.

Danger:

  Locate and lock supply breaker in the OFF position before wiring 

to power terminal blocks.

2.

Run 120V power wiring into the panel. Locations to run power wiring 
into the panel are shown in Figure 1. Terminal blocks will accept 26 
through 14 AWG wire. Tighten terminal blocks to 3.5 to 5 in-lbs. (.40 to 
.57 Nm). Do not overtighten.

3.

Install the ALD-D48 Processor in accordance with instructions 
provided with the board.

4.

If not installing the board at this time, leave these instructions inside 
the enclosure.

5.

Install cover. Ensure the vents are on the right side of the cover. 
Tighten screws to 20 in-lbs. (2.3 Nm).

What You Will Find

Description

Item Number

Rough-In enclosure with cover

MA2604-01

includes 15VDC Power Supply

57-0425

ALD-D48 Controller Board Assembly

MA2604-02

includes controller hardware pack

Quick Start Guides

ALD-D48 Controller Assembly

93-2604

ALD-D48 Enclosure Rough-In

93-2604-01

Optional Accessories

Description

Item Number

ALD-1000D, 1000 W/VA Vareo Dimmer

FG2604-10

ALD-600D, 60 W/VA Vareo Dimmer

FG2604-20

ALD-1000NS, 1000 W/VA Vareo Switch

FG2604-30

ALD-VETS-R, Auxiliary Switch for Vareo

FG2604-40

ALD-VWP-2, 2 Gang Wallplate

FG2604-60

ALD-VWP-3, 3 Gang Wallplate

FG2604-61

ALD-VWP-4, 4 Gang Wallplate

FG2604-62

FIG. 1  

ALD-D48 Rough-In enclosure

FIG. 2  

Recommended cutout (not to scale)

Vented cover

120V power supply

Surface
mount
keyholes

Rough-In
enclosure

9.37

17.37

9.59

0.11

.55

.55

0.06

.06

13.00

2.06

Enclosure
cover
outline

.55"

(1.40 cm)

13.00" (33.02 cm)

9.37"

(23.80 cm)

.55"

(1.40 cm)

0.06"

(0.15 cm)

17.37" (44.12 cm)

.06"

(0.15 cm)

9.59"

(24.36 cm)

0.11"

(0.28 cm)

2.06" (5.23cm)

R0.125

Отзывы: