Lupo SUPERPANEL DUAL COLOR 30 Скачать руководство пользователя страница 5

DMX OPERATION

 - Advanced Settings

LIGHT MODES

1.  Press the 

« OK »

 

 2

 button to enter the main MENU. 

2.  Navigate through the main MENU with the 

«   »

 

 1

 

or 

«   » 

 3

 buttons to the 

DMX 

item, 

select by pressing the 

« OK »

 

 2

 button.

3.  Press the 

«   »

 

 1

 

or 

«   » 

 3

 buttons to select 

DMX ADVANCED, 

press 

« OK »

 

 2

 button to 

confirm selection.

4.  Select one of the options between the 

DMX BIT

 and 

DMX SIGNAL LOSS,

 press 

« OK »

 

 2

 to 

confirm the selection.

DMX BIT: 

Resolution of the DMX control. 8bit 1 channel per function and 16 bit 2 channels per 

function. 
1.  Select the 

DMX BIT

 item by pressing the 

« OK »

 

 2

 button. 

2.  Use the 

«   »

 

 1

 

or 

«   » 

 3

 buttons to choose between 

8bit / 16bit

, press the 

« OK »

 

 2

  

button to confirm the selected setting. 

See

 

DMX PROTOCOL MANUAL

.

DMX SIGNAL LOSS:

 

T

his feature allows to choose the device’s behaviour in case of a DMX signal loss.

1.  Select the 

LOSS DMX SIGNAL

 item with the 

« OK »

 

 2

 button.

2.  Use the 

«   »

 

 1

 

or 

«   » 

 3

 buttons to select the device’s behaviour between 

BLACK 

OUT /SETTINGS LAST / SETTINGS 1min

, press the 

« OK »

 

 2

 button to confirm the 

setting. 

Black out:

 

The device switches off.

Settings Last:

 

The values of the last selected setting are maintained over time until the 

device is switched off.

Settings 1min:

 

The values of the last selected settings will be maintained for one minute 

and then the device will switch off.

A. CCT MODE: 

Warm and cold white control mode. It allows you to adjust colour temperature 

(CCT), green/magenta compensation (GN) and light intensity. 

This is the default setting.

 

B.  HSI MODE: 

Colour composition mode. It allows you to adjust hue of colour (HUE), colour 

saturation (SAT) and light intensity. 

C. RGBW MODE:

 

RGBW colour control mode allows to individually set the R, G, B, W, Color 

Temperature (CT), green/magenta compensation (GN) values and to adjust light intensity

D.  FRGBW MODE:

 Available only in DMX operation. Same as RGBW but with white color 

power unlimited. 

See

 

DMX PROTOCOL MANUAL

.

 

MODE

CCT

RGBW

HSI

PRESET

EFFECT

CCT/HUE

 

 

5

  

CT 2800K to 10000K

-

HUE 0º to 100º

-

"See EFFECT table" 

GN/SAT/COLOR

 

 

6

 

«   »

 

 1

 

«   »

 

 

3

 

GN -1.00 to +1.00 

-

Select function R/G/B/W/CT/GN

Change values of the function

SAT 0 to 100%

-

-

"See EFFECT table"

Change Preset

Change Effect

INTENSITY

 

 

4

  

Light Intensity

from 0 to 100%

Содержание SUPERPANEL DUAL COLOR 30

Страница 1: ...Superpanel FULL COLOR 30 User Manual...

Страница 2: ...t contains electrical and electronic components that could be harmful to the environment Equipment may be returned to Lupo distributors free of charge for recycling according to WEEE Follow local lega...

Страница 3: ...d As prescribed by international regulations a safety cable must be used when the fixture is suspended from ceiling To switch on the light push the on off button Superpanel models are equipped with ne...

Страница 4: ...ng the OK 2 button 3 Select the light mode between CCT HSI RGBW PRESET EFFECT with the 1 or 3 button press OK 2 to confirm selection 4 See LIGHT MODES DMX OPERATION 1 Press the OK 2 button to enter th...

Страница 5: ...ton to confirm the setting Black out The device switches off Settings Last The values of the last selected setting are maintained over time until the device is switched off Settings 1min The values of...

Страница 6: ...rrent mode use the 1 o 3 button to change the PRESET in ascending or descending order THE PRESET ON THE DISPLAY IS THE SELECTED PRESET 4 Use the INTENSITY 4 knob to adjust the light intensity from 0 t...

Страница 7: ...nsation curve for the human eye s perception of the luminous intensity emitted as a function of the required power Required power dimmer value on the display LINEAR EXPONENTIAL LOGARITHMIC Linear No c...

Страница 8: ...EXIT DMX CCT LIMIT 3200K 5600K 2800K 10000K BACK YES BACK DISPLAY OPTIONS 30 SEC 1 MIN ALWAYS ON BACK FILTER FULL SPEED NORMAL SPEED HIGH SPEED LINEARIZATION MENU VIEW EXIT EXIT LINEAR ONLY MANUAL BAC...