Reserve tank: 

When the battery is almost empty (red LED have flashed for several minutes already) the lamp 
switches  off  automatically.  By  double  clicking  the  switch  the  reserve  tank  is  activated,  which 
provides  some  additonal  time  of  emergency  light. 

The  flashing  red  LED  indicates  the 

reserve tank has been activated.

 The performance of the reserve tank also depends on the 

battery condition.  
 
When the reserve tank is empty, the light will switch off and must not be restarted. 
 

Never store a discharged battery. Recharge your battery as soon as possible!

 

 

    

 

 

 

4.)

 

C

HARGING THE RECHARGEABLE BATTERY

 

 

Components: 

The charging system of the TL 700  consists of two components: 

-

 

AC/DC adaptor 

-

 

Micro-Charger 

The  Micro-Charger  was  developed  for  use  with  Lupine’s  high  current  Li-Ion  rechargeable 
batteries from  AC/DC adaptor or with additional available 12 V car adaptor.   

       

     

Connection:  

Plug the AC/DC adaptor into the mains. Plug the adaptor into the socket of the Micro-Charger. 
After a short green flash the Micro-Charger flashes orange and will be now ready to charge. 
 

    

Charging: 

Plug  the  rechargeable  battery  into  the  Micro-Charger’s  connector    and  charging  will  start 
automatically. The orange LED  and the blue LED light.  

Keep  the  rechargeable  battery  plugged  into  the  Micro-Charger  until  the  green  LED 
lights. 

Charging is now complete; the battery is full and is now ready for use. 

 

 
Reading the charged capacity: 

After disconnecting  the battery the Micro-Charger  will indicate the charged capacity as 

follows: 

 

First, the    orange LED will blink 1 time per complete ampere hour,  
then  the     green  LED will blink 1 time per 1/10 ampere hour.

 

 

Example: The orange LED blinks 1 times and the green LED 5 times = the charged capacity is 
around 1,5 Ah. This information will help you to judge the actual condition of your 
rechargeable battery before use.  
 

Hint:

 You don’t have to wait for the whole voltage information to be shown in order to use 

your charger again. You can stop the charge information at any time by connecting the 
battery. 
 

    Caution!! 

Micro-Charger  is designed to charge only Li-Ion batteries! 

You  must  not  use  this  charger  with  Ni-MH  batteries  or  unrechargeable  batteries!! 
They will explode!!

  

Micro-Charger should not be opened by the user as this will invalidate the warranty.  
 

      

Explanation of the LEDs:

 

Orange:   

Charging 

Green: 

 

Rechargeable battery full 

 

 

Содержание TL700

Страница 1: ...Instruction Manual Read before use Content of package 12 W programmable High Power LED Torch Li Ion battery 2 5 Ah 7 2V Lupine Micro Charger with AC DC adaptor 12 V car adaptor Instruction Manual this document ...

Страница 2: ...be fully charged see chapter 4 Charging The rechargeable Li Ion battery will reach its full power after 1 charge cycle It might become hot The TL 700 is not a simple torch The lamp housing can become very hot if used without airflow Do not touch the lamp during or immediately after use If lamp is used without any airflow temperature control will reduce light power stepless up to 3 W after some min...

Страница 3: ... as follows First the blue LED will blink 1 time per complete ampere hour then the green LED will blink 1 time per 1 10 ampere hour Example The blue LED blinks 1 time and the green LED 5 times the gone capacity is around 1 5 Ah This information will help you to judge the actual condition of your rechargeable battery before the next use Hint PCS will count the consumed capacity always if the lamp u...

Страница 4: ...ing Plug the rechargeable battery into the Micro Charger s connector and charging will start automatically The orange LED and the blue LED light Keep the rechargeable battery plugged into the Micro Charger until the green LED lights Charging is now complete the battery is full and is now ready for use Reading the charged capacity After disconnecting the battery the Micro Charger will indicate the ...

Страница 5: ...t down until the light flashes the required number of times and then release If the light is turned OFF and you start the programming sequence please ignore the first light flash If the light is turned ON when you start the programming sequence the first flash you see is stage 1 of programming 2 Step Mode Keep the button pressed and then release for 5 seconds 1 st flash green 2 step low for 10 sec...

Страница 6: ...It takes some experience of using the lighting system to tell exactly how much burn time is left when the yellow LED lights up Accordingly it also varies how much burn time is left when the red LED lights up The factory default capacity control will be suitable for a long time It is not recommended to change the capacity control until you have experienced a remarkable loss of burn time 5 CARE AND ...

Страница 7: ...p unit Before using the system again re charge the battery fully If you intend not to use it for a longer period over 3 months we strongly recommend to store the battery in a cold place This will prevent the battery from over discharging 6 TROUBLESHOOTING Failure Caused by Solution Over discharged battery Charge Lamp does not light and the LEDs on the Lamp do not light during initialisation Batter...

Страница 8: ...rging current 2 A max Suitable batteries Li Ion 2 cells 7 2 V Display Control of charging by a green LED Charge Time max1 5 hr IMPORTANT NOTES Use of this lighting system might be limited differently from country to country depending on the purpose you use it for Please do inform yourself about possible restrictions in your country The design of the TL 700 as well as of the PCS are protected by wo...

Отзывы: