![Lunos Silvento V AC Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/lunos/silvento-v-ac/silvento-v-ac_installation-manual_1950118011.webp)
11
Electrical connection
-
connection diagrams
EN
Two
-
room ventilator
Single
-
stage operation, switchable to 60 m³/h from 2
rooms
5/W
Bridge
5/W
Bridge
Room lighting
Room 1
35 m³/h
Room 2
25 m³/h
3
Bridge
1
2
4
Single
-
stage operation, switchable to 60 m
3
/h
(Ventilator types ... 30/60)
5/W
Bridge
Bridge
5/W
Bridge
5/W2
Bridge
Room lighting
Room lighting
Continuous operation 30 m
3
/h, switchable to 60m
3
/h or 90
m
3
/h (L2)
Safety instructions:
Caution! Any assembly work to the ventilation device may only be carried out after disconnecting the supply
voltage! The ventilation device is fitted with protective insulation according to Protection Class II, a protective
conductor connection is not required!
Make sure that the supply voltage of all connection lines is voltage
-
free (dead)! (Separation from the power
supply with a minimum contact opening of 3 mm, e.g. electric fuse).
Each electric circuit of this ventilation system must be fitted with a residual current protection (e.g. FI switch/
RCCB)!
Additional installations and electrical components in the ventilation unit are not allowed!
Connection diagrams for further fan functions upon request!
Two room ventilator
Single
-
stage operation, switchable to 90 m
3
/h from two
rooms
Room 1
60 m³/h
Room 2
40 m³/h
Room lighting
Bridge
5/W2