9-7
EQUIPMENT DETAILS
MAIN MENU
Press MENU button to access the Main Menu
from the Standby Screen or Settings Menu.
The screen will revert to the Standby Screen
after 30 secs if untouched.
1. Standby Screen.
Press MENU button.
2.
Main Menu.
a.
What’s Activated Menu. [Not displayed
if no activated functions are detected.]
b.
Settings Menu
Desired Room Temperature
The desired room temperature can be
set from 5 to 30
°
C, in 0.5 increments.
Tip!
The World Health Organisation
recommends a room temperature of
18–24
°
C for healthy living.
NB:
If Day or Night Mode are active, the
temperature cannot be adjusted, the Plus and
Minus buttons will be greyed out.
1.
The current desired room temperature is
displayed.
2.
Adjust by pressing Plus or Minus button.
Domestic Hot Water
The Alde boiler stores 8.4 Litres of hot
water as standard. If the hot water
cylinder is empty, the air is heated but
no damage can result.
Tip!
In a good summer, for example, lower
the desired temperature on the control panel
to around 10
°
C. The central heating will not
circulate (unless the temperature drops to
10
°
C), but you can still control hot water.
NB:
If Day or Night Mode Sans Hot Water
are active, the hot water cannot be adjusted,
the Plus and Minus buttons will be greyed
out.
1. Hot Water Ignore. Volume bar empty. No
attempt is made to heat hot water
specifically. This saves energy when the
freshwater is drained down.
2. Hot Water Normal. Volume bar half-full.
Hot water is heated to greater than 50
°
C.
NB: If Circulation Pump is set to
Continuous, this option will not be
available.
3. Hot Water Boost. Volume bar full. Central
heating circulation is disabled for 30
mins. Hot water is heated to greater than
65
°
C. After 30 mins the system reverts to
Hot Water Normal.
4. Adjust by pressing Plus or Minus button.
Electric Heating
Check that 230V supply is displayed
on the Standby Screen. The Alde
boiler is programmed to use power
economically and there are times
when it may use no power at all, even
if set to 3 kW.
1.
Select Off, 1, 2 or 3 kW electric heating.
More power equals better performance, but
may be restricted by the current (amps) limit
on the electric hook-up.
2.
Adjust by pressing Plus or Minus button.
Max current draw from 230 V supply is 4.5 A
on 1 kW, 9 A on 2 kW, 14 A on 3 kW. If the
electric supply has unstable voltage, the
amperage will also fluctuate.
Gas Heating
The Alde boiler is programmed to use
power economically. The gas burner
has two stages, shifting dynamically
between low or full flame. There are
times when it may use no power at
all, even if gas heating is selected.
1.
Press the Flame button to select gas
heating. Green is on, blue is off.
Use both gas and electric heating for best
performance.
Содержание Cassini EB 2018
Страница 2: ......
Страница 4: ...1 2 INTRODUCTION INTRODUCTION...
Страница 14: ...6 2 ARRIVAL ON SITE...
Страница 33: ...8 15 Ventilation Cassini TI Ventilation Roadstar EB Ventilation Roadstar EL Ventilation Roadstar TI SERVICES...
Страница 56: ...8 38 WIRING DIAGRAMS...
Страница 57: ...8 39 WIRING DIAGRAMS...
Страница 58: ...8 40 WIRING DIAGRAMS...
Страница 59: ...8 41 WIRING DIAGRAMS...
Страница 60: ...8 42 CABLE COLOUR CHARTS...
Страница 106: ...9 46 EQUIPMENT DETAILS...
Страница 114: ...11 4 WARRANTY...
Страница 115: ...12 1 NOTES...
Страница 116: ...12 2 NOTES...
Страница 117: ...12 3 NOTES...
Страница 118: ...12 4 NOTES...
Страница 124: ...15 2 Designed and Printed by Preset Graphics Tel 01332 549278 Ref 21608...