Page 6
4.0 REMOVING THE HD CAMERA INSERT MODULE
!! IMPORTANT:
Care must be taken to ensure the lens is not damaged before removing the camera module. If the lens on the
Thru-Hull has been damaged and the Camera Insert Module is removed, water will enter the vessel.
The interchangeable module should only be removed after consultation with Lumishore and only in the event of camera
failure or module upgrade.
● Replacement is easily performed. However, full instructions are available from Lumishore to ensure that this is
done in a way that optimises the life of the unit.
● Unauthorised removal of the insert will result in the warranty being void.
5.0 ELECTRICAL CONNECTIONS
5.1 Fuse Installation
Each camera should be individually fused, the TIX402 HD camera module is supplied with an external fuse holder and
two fuses. The correct fuse for 12 Volts is a 1 A fuse
5.2 Cable size (Gauge)
LUMISHORE cameras have advanced electronic systems that protect them from under current or voltage.
Note: Current draw per module with a camera connected: 12VDC
– 0.25 A
● Proper wire cable size must be considered when installing the cameras.
● Compute the gauge of the cable needed camera at 12VDC
● Cable lengths referenced in the Conductor Size tables are from the source to the cameras and back to the
source.
Calculate the total current draw of all products that are connected to the terminal strip and use the chart below to find
cable size from power source to terminal strip. Use the same size wire from the terminal strip to each camera.