Installation Diagram - ECLIPSE Command Center
Note: For full ECLIPSE Command Center control consult ECLIPSE Command Center installation manual.
Mechanical Installation:
The body is designed to be fitted through a 1in hole, however, it is always recommended cut the hole smaller
than needed and file to the correct size to ensure a snug fit.
(0.90in)
Ø23mm
Important! Use appropriate size cable gauge to
ensure < 3% voltage drop to last light in chain.
RED
BLK
RED
BLK
RED
BLK
RED
WHT
BLU
YEL
ECLIPSE Command Center
ECLIPSE Cable
Harness
CONNECT AS BELOW;
ECLIPSE cable harness RED to CL30 RED
ECLIPSE cable harness BLU and WHT to CL30 BLK
Select and install appropriate blade
fuse for complete circuit
Max 32 Lights
YEL - No connect.
Ensure any unused wires are isolated.
Note : Single color and dual color lights should not be added to the same zone output. Use a separate zone
output for each type.