WARNINGS

WARNING: TENS devices must be kept out of reach of children.
WARNING: The safety of TENS devices for use during pregnancy or 

delivery has not been established.

Always follow basic safety precautions, including the following:

SAFETY

WARNING: Indicates a potential hazard situation or unsafe practice that,

if not avoided, could result in death or serious personal injury.
CAUTION: Indicates a potential hazard or unsafe practice that, if not

avoided, could result in minor personal injury or product/property damage.

WARNING: TENS is not effective for pain of central origin (headaches). 
WARNING: If TENS treatment becomes ineffective or unpleasant, 

stimulation should be discontinued until evaluated by a physician.
WARNING: Avoid adjusting controls while operating machinery or vehicles.
WARNING: Always turn the TENS device OFF before applying or removing electrodes.
WARNING: TENS may interfere with electronic monitoring equipment 

(ECG monitors/alarms).
WARNING: Electrodes should not be placed over the eyes, in the mouth, 

WARNING: TENS devices have no curative value.
WARNING: TENS is a symptomatic treatment and as such suppresses the 

sensation if pain which would otherwise serve as a protective mechanism.

or internally.

04

WARNING: Notice for California Customers- California Proposition 65 

WARNING: This product contains a chemical known to the State of California

to cause cancer and reproductive or developmental harm.

PRECAUTIONS/ADVERSE REACTIONS

CAUTION: Isolated cases of skin irritation may occur at the site of electrode 

placement during long term application.
CAUTION: Effectiveness is highly dependent upon patient selection by a  

person qualified in the management of pain patients.
CAUTION: Skin irritation and electrode burns are potential adverse reactions.

Содержание LUMI-TENS

Страница 1: ...timulation Device Operation Manual Read this manual before operating your LUMI TENS Save this manual for future use The most current version of this manual can be found online at www grahamfield com L...

Страница 2: ...N 8 CARING FOR YOUR TENS DEVICE 9 TROUBLESHOOTING 9 SYSTEM COMPONENTS 9 TECHNICAL SPECIFICATIONS 10 OUTPUT SPECIFICATIONS 10 WARRANTY 11 GF Health Products Inc is not responsible for typographical err...

Страница 3: ...ent for many patients By reading this manual and carefully following the treatment instructions given to you by your clinician you can attain the maximum benefit from your TENS device INDICATIONS AND...

Страница 4: ...les WARNING Always turn the TENS device OFF before applying or removing electrodes WARNING TENS may interfere with electronic monitoring equipment ECG monitors alarms WARNING Electrodes should not be...

Страница 5: ...trol Battery Compartment Battery Strip 5 ABOUT THIS DEVICE Your TENS device is a battery operated device that includes two controllable output channels This TENS device creates electrical impulses who...

Страница 6: ...termined by Intensity Rate and Width Knobs Modulation M Pulse Width decreases the Pulse Width down to 60 of the original width setting This decreased Pulse Width is maintained for 1 5 seconds before r...

Страница 7: ...ance of skin irritation and extend the life of your electrodes Avoid excessive stretching of the skin when applying electrodes Proper application is best accomplished by applying the electrode then sm...

Страница 8: ...comfortable level or cease stimulation and contact your physician BATTERY INFORMATION When the yellow indicator light located on the front of the unit will no longer illuminate the battery has become...

Страница 9: ...not stay lit when the unit is turned on replace the battery and check again 2 If the ON OFF Indicator Light is flashing and no stimulation is felt check to ensure lead wires are properly connected and...

Страница 10: ...z 150Hz adjustable 30uS 260uS adjustable Burst consists 2 burst per sec at 100 Hz Asymmetrical Bi Phasic square pulse 0 100 Volt open current 9 volt battery 95 H x 65 W x 23 5 T mm 115 grams battery i...

Страница 11: ...r e mail cs grahamfield com Failure to follow the specific directions provided by the GF customer service team will result in denial of the warranty claim ENTIRE WARRANTY EXCLUSIVE REMEDY AND CONSEQUE...

Страница 12: ...Manufactured for GF Health Products Inc 2935 Northeast Parkway Atlanta Georgia 30360 telephone 770 368 4700 fax 770 368 2386 2008 GF Health Products Inc Made in Taiwan www grahamfield com...

Отзывы: