background image

L2214-INS-LAB-RevD10

Features

1.  Fast oral temperature measurement in approximately 10 seconds.
2.  Very sensitive unit; best for quick oral and rectal measurement.
3.  Easy to read digital LCD (Liquid Crystal Display).

4.  Flexible soft tip fits naturally under tongue or under arm. Won’t poke or hurt. Flexible probe conforms 

to different mouths.

5.  Compact, accurate and durable LSI (Large Scale Integration) unit.

6.  If the thermometer is inadvertently left on after temperature stabilization, it will automatically shut off in 

about 10 minutes.

7.  Small, lightweight unit. Universal use for the whole family.
8.  Less hazardous than mercury glass thermometers.
9.  Low battery indicator: when the symbol “

” appears, the battery needs to be replaced.

10. This unit is waterproof.

Parts Description

Specifications                                                  

Range 

90°F ~ 109.3°F (32.0°C ~ 42.9°C) 

 

< 90.0°F (32.0°C) displays Lo°F (°C) 

 

> 109.9°F (42.9°C) displays Hi°F (°C)

Resolution 

0.1° F (°C)

Accuracy 

±0.2°F (93.2°F to 107.6°F) ±0.4°F (other range)

 

 

±0.1°C (34.0°C to 42.0°C) ±0.2°C (other range)

Display 

LCD (Liquid Crystal Display) 3 ½ digits

Battery (included 

Micro alkaline battery 192.LR41.1 5.5V

Power Consumption 

0.15 milliwatts in measurement mode

Battery Life 

> 200 hours continuous operation

Dimensions 

5.28 in x .98 in x .47 in (134 mm x 25 mm x 12 mm) 

Weight 

Approximately 0.03 lb (14 g) including battery

Beeper 

Approximately 8 seconds sound signal when peak temperature is reached

Memory 

Built-in memory enables display of previously measured value

Operation Environment  Temperature 50°F ~ 95°F (10°C ~ 35°C ) 

 

Humidity 

30% ~ 75% RH

Storage Environment  

Temperature 13°F ~ 140°F (-25°C ~ 60°C )

Guarantee of Quality 

Certification ISO 13485

 

 

Conformity EN12470-3, EN60601-1

Product Classification 

Type BF 

 equipment

Precautions — Care and Maintenance

1.  Do not boil the probe. Clean the thermometer by wiping it with a clean, dry cloth, and disinfect the 

probe with isopropyl alcohol.

2.  Do not drop the thermometer or expose it to heavy shock. The thermometer is not shockproof.
3.  Do not bend or bite the probe.
4.  Do not store the thermometer in direct sunlight, high temperature, high humidity, or in a dusty environ

-

ment. Performance may be degraded.

5.  Stop using the thermometer if it operates erratically or if the display malfunctions.
6.  Keep thermometer out of the reach of children and always supervise children during measurement.
7.  Clean the thermometer probe before storing.
8.  Do not disassemble the thermometer except to replace the battery.
9.  If the thermometer has been stored at below-freezing temperatures, allow it to warm naturally to room 

temperature before use.

10. Thermometer performance may be degraded if operated or stored outside recommended temperature 

and humidity ranges shown in Specifications section above, or if the patient’s temperature is below 

ambient (room) temperature.

Battery Replacement

1.  When the symbol “

” appears, the battery needs to be replaced.

2.  Pull the battery cover off in the direction shown below.
3.  If necessary, use a pointed object such as a toothpick or insulated 

probe to gently pry the battery cover and battery loose; avoid using 

a sharp metal object for this operation.

4.  Place a new 1.55 VDC button-size battery, type 192.LR41 or 

equivalent, in the battery chamber with negative side (–) up and 

positive side (+) down.

5.  Replace and fasten the battery cover securely.

Warning: Discard the old battery carefully, out of the reach of children. Swallowing the battery 

could be harmful or fatal. If the battery is inadvertently swallowed, contact a hospital immedi-

ately to have it removed. Do not dispose of the battery in a fire. It may explode.

Model L2214

Digital Thermometer

INSTRUCTIONS FOR USE

Please read carefully before using

How to Use the Thermometer

1.  Depress the ON/OFF button. The display will show 

 or 

 .

2.  Release the ON/OFF button. The display will show Lo°F (Lo°C) with °F (°C) flashing.
2.  Disinfect the probe with isopropyl alcohol. See instructions below to place the probe in an appropriate 

position (oral, axillary, or rectal).

3.  Once the degree sign (°F or °C) has stopped flashing, usually within 15-30 seconds, the correct tem

-

perature is shown. The temperature showing will not change after the °F (°C) has stopped flashing.

4.  The thermometer will automatically turn off in approximately 9 minutes. However, to prolong battery 

life, it is best to turn the thermometer off by pressing the ON/OFF button once the temperature has 

been noted.

Special Features

Normal Temperature Alarm: When the peak temperature has registered and is ready to read, an alarm will 

sound. The “Normal Temperature” alarm (10 beeps) will sound for approximately 8 seconds.
Fever Alarm: When the peak temperature has registered higher than 99.5°F (37.5°C), the fever alarm 

(approximately 10 seconds of quick beeps) will sound.
Automatic Last Temperature Recall: When the ON/OFF button is pressed to activate the thermometer, 

display 188.8 will change to show the last measured temperature value, then return to “ready to measure” 

mode.

Fahrenheit and Celsius Switchable: The Fahrenheit or Celsius mode can be switched by pressing the 

ON/OFF button within the first 5 seconds.

Note: Always disinfect the thermometer before use.
Note: In Step 2, if the room temperature is greater than 90.0°F (32.0°C), it will be displayed rather than 

Lo°F (°C).
Note: In Step 3, you may put a sanitary plastic probe shield on the sensor tip to help prevent cross 

infection and contamination. Use of the probe cover may result in a 0.2°F (0.1°C) difference from actual 

temperature. Dispose of any used probe shield and store the thermometer in a safe place.

Reliable Methods to Measure Temperature

Measuring Body Temperature:

 Change in body temperature is one of the most important indicators of 

illness. It is important that accurate temperatures be taken. Even though the digital thermometer is used 

in similar manner to the glass thermometer, instructions for use of this thermometer must be followed 

closely, and the person taking the temperature must understand body temperature.

Body Temperature:

 A persons’s body temperature is usually several tenths to one full degree lower in 

the morning than in the late afternoon. Therefore, if your temperature in the morning is 97.9°F (36.6°C), it 

could be 98.4°F (36.9°C) or more in the late afternoon and still be normal. To determine what your normal 

body temperature is, you should take your temperature both in the early morning and late afternoon over 

several days. Children have the same normal temperature range as adults. A fever bor both children and 

adults in typically defined as an oral temperature higher than 99.5°F (37.5°C). Exercise, excessive cloth

-

ing, hot bath, hot weather, and warm food and drink can cause mild elevations of up to 100.4°F (38°C) 

in oral temperature. If you suspect one of these to be the cause of an elevated reading, eliminate the 

possible cause and retake the temperature in half an hour.

Oral Use

Place the probe well under the patient’s tongue. Instruct the patient to 

keep their mouth closed while the thermometer is measuring. A normal 

oral temperature is usually considered to be between 96.8°F – 98.6°F 

(36.0°C – 37.5°C).

Rectal Use

If rectal temperature is recommended by your doctor, you may use a probe cover. Insert thermometer 

tip into the probe cover. Lubricate the probe cover with a water soluble jelly for easier insertion. Do not 

use petroleum jelly. Insert tip of probe no more than ½ inch into rectum. Stop if you meet any resistance. 

The sensing device is on the very tip of the probe and there is no need to insert the probe deep into 

the rectum. Rectal temperature is usually approximately 1.0°F – 2.0°F (0.5°C – 1.0°C) higher than oral 

temperature.

Axillary Use (Armpit)

Wipe armpit with a dry towel. Place probe in the patient’s armpit and keep the patient’s arm pressed firmly 

against their side. Axillary temperature is usually approximately 1.0°F – 2.0°F (0.5°C – 1.0°C) lower than 

oral temperature. Note: In order to achieve better axillary temperature measurement result, a minimum 

measuring time of 3-5 minutes is recommended regardless of the beep sound.

Note: Children should be attended by an adult during the entire temperature recording process. After 

use, the digital thermometer should be stored in a safe place, out of the reach of children. If you compare 

temperatures between two thermometers, it is possible to have two different readings, even if both 

thermometers are within their accuracy tolerances. Differences in how you take each reading and the 

thermometer’s tolerance range can account for nearly 0.2°F (0.1°C) variability.

Remember: Find your normal temperature and watch for changes.

Cleaning Instructions

To clean the thermometer, wash the tip with a solution of mild detergent and cool water. To disinfect the 

thermometer, wipe the sensor and lower stem with a clean cloth dipped in isopropyl alcohol.

Limited warranty

This thermometer is guaranteed against manufacturer’s defects under normal household use for one year 

from the date of purchase. Following the instructions closely will ensure years of dependable operation. 

If the thermometer does not function properly, first check the battery and replace it if necessary (see 

instructions above). Repair Department: 1-800-672-8293.

Manufactured for GF Health Products, Inc.

 

Atlanta, Georgia  30360

© 2010 GF Health Products, Inc.

 

Made in China

 

www.grahamfield.com

Отзывы: