4.7.2 Recall a Profi le:

To recall a profi le, select it amongst the ten available profi les in the up-

per tab. Here you can preview the content of this profi le.

Click on the 

Recall

 button. A window will pop-up to let you select ei-

ther to reload all the confi guration settings (Recall All), including the 

network settings, or just the switch confi guration (No Network Set-

tings). This very useful feature makes the exchange of profi les between 

switches possible. You can thus avoid getting the same IP address 

twice in the network by using the same profi le.

Once you have selected the profi le you wish to recall, the switch will 

reboot and will reload the requested profi le.

The recall process can take a minimum of 30 seconds to a maximum 

of 2 minutes.

If you intend to reload a profi le with a diff erent IP address, you can try 

to reach the newly loaded IP address after about 50 seconds, manually 

from the switch’s web interface.

Otherwise, the web interface of the switch will be automatically re-

loaded after a maximum of 2 minutes. Your computer’s IP address 

needs to be set in the same subnet mask as the loaded profi le’s IP.

PLEASE KEEP IN MIND THE WEB INTERFACE OF A SWITCH 

CAN ONLY BE REACHED THROUGH A PORT ASSIGNED IN 

THE MANAGEMENT GROUP (FROM THE SWITCH YOU’RE 

CONNECTED TO, OR FROM ANOTHER SWITCH THROUGH 

AN ISL PORT). PAY ATTENTION THE PROFILE YOU’RE GO-

ING TO RECALL IS NOT CHANGING YOUR LINK TO THE WEB 

INTERFACE OF THE SWITCH YOU’RE WORKING WITH. ALSO 

PAY ATTENTION THAT THE IP ADDRESS THAT WILL BE RE-

LOADED WITH THE PROFILE DOESN’T CONFLICT WITH AN-

OTHER IP IN THE NETWORK. THE SWITCH’S WEB INTERFACE 

MAY BECOME UNRESPONSIVE IN CASE OF AN IP CONFLICT.

4.7.3 Export a profi le:

To export a profi le, select it amongst the ten available slots. Once se-

lected, click the 

Export

 button to download the profi le to your com-

puter. You’ll be asked to select the download location of the profi le on 

your computer.

4.7.4 Import a Profi le:

To import a profi le, select an empty slot in the profi le manager tab. 

Once selected click the 

Import

 button to select the profi le on your 

computer. Once the fi le is selected, validate to import the profi le in 

the empty slot. A message will confi rm the successful import process.

4.7.5 Delete a Profi le:

To delete a profi le, select the profi le in question and click 

Delete

. The 

profi le will automatically be erased, and the preview window will dis-

play an empty space.

WHEN USERS SAVE A PROFILE, THE OK LED WILL BLINK 

GREEN FOR ABOUT 5 SECONDS TO INDICATE THE WRITING PRO-

CESS TO THE FLASH MEMORY. PLEASE DO NOT SWITCH OFF 

POWER TO THE UNIT WHILE THE OK LED IS BLINKING GREEN! 

YOUR SWITCH CONFIGURATION MIGHT BE ERASED DURING THE 

NEXT BOOT UP.

4.7.6 Default Profi le:

As described in section 3.3.3, the fi rst slot of the profi le manager can 

be locked. This will be indicated by a padlock on the profi le itself. This 

profi le can’t be erased nor overwritten, unless you unlock it. To unlock 

the profi le, untick the checkbox in Global>Utilities.

23

4 | CONFIGURATION / 

4.7 PROFILE MANAGER

Содержание GigaCore 10

Страница 1: ...USER MANUAL GIGACORE PRODUCT FAMILY GigaCore 12 THANKS FOR CHOOSING LUMINEX Description User Manual GigaCore 12 REVISION 20220623 REV 2 8 7...

Страница 2: ...PARTS INSIDE REFER SERVICING TO QUALIFIED SERVICE PERSONEL AVERTISSEMENT AUCUNE PI CE CONTENUE L INT RIEUR NE PEUT ETRE R PAR E PAR L UTILISATEUR VEUILLEZ CONFIER TOUTE R PARATION UN PERSONNEL QUALIF...

Страница 3: ...ronic equipment please contact your dealer or supplier for further information Information on Disposal in other Countries outside the European Union This symbol is only valid in the European Union If...

Страница 4: ...3 GIGACORE FEATURES EXPLAINED 9 3 1 RlinkX 9 3 2 Groups VLANs 10 3 3 MultiLinkX 10 4 CONFIGURATION 12 4 1 Connecting to the web interface 12 4 2 Status Page 12 4 3 Global Page 14 4 4 RlinkX 17 4 5 Gr...

Страница 5: ...n all your lighting audio and video protocols to di erent co lour groups and send them over the same network Luminex takes care of the rest and makes sure every device receives the right signal ArtNet...

Страница 6: ...gain After connecting the power cable correctly the power LED indicator on the front panel will light up green The GigaCore 12 and GigaCore 12 with PoE requires standard AC power distribution from 100...

Страница 7: ...port RlinkX Shows the status of RlinkX for each port Port Link Speed Shows the status of RlinkX for each port C ETHERCON PORTS 10x EtherCon 10 100 1000Mbs port D REAR PORT STATUS LEDS RlinkX Shows th...

Страница 8: ...to default The user pro les will be preserved though For more detailed information on how to reset the device and what reset options are available please check chapter 5 of this manual 2 4 LED indica...

Страница 9: ...ween20and40ms By default all GigaCore ports have RLinkX enabled which means you can interconnect any GigaCore switch between each other All redun dant paths will be created automatically by the switch...

Страница 10: ...t of the time a redundant link set with RLinkX between two Gi gaCore switches will be good for the everyday event A 1000Mbps link is more than enough for most of the current applications However it ca...

Страница 11: ...the following parameters Source Mac Address Source IP Address Source Port TCP UDP Destination IP Address Destination Port TCP UDP The ports included in the aggregation Rx 400Mbps Rx 400Mbps Rx 400Mbp...

Страница 12: ...55 255 0 0 Connect your computer to the switch with a network cable and launch your favourite web browser Type the IP address of the switch in the address eld and press enter You ll be prompted to ent...

Страница 13: ...Dynamic Host Con guration Protocol 4 3 Global Page The global page consists of four sub menus If your network is equipped with a DHCP server you can enable the DHCP client of the switch for it to rece...

Страница 14: ...ault security parameters A Reset This menu allows the user to bring the switch into di erent levels of reset 1 Preserve IP Settings Tick the upper checkbox if you wish to bring the device back to the...

Страница 15: ...recover from this o set is to restart the switch and thus reset the ber PHYs to eliminate the o set This is needed to have a synchronized system Via the utilities web page of the GigaCore theusercanno...

Страница 16: ...to reload the previous rmware The downgrade process takes about 1 minute C Security The user can use this feature to set a password to protect the access to the web interface The default login for th...

Страница 17: ...y is active and operational 4 4 1 Advanced MultiLinkX ouraggregationprotocol hasbeendesignedtowork aw lessly with RLinkX our redundancy protocol To provide users with a more advanced and e cient metho...

Страница 18: ...u need to have at least one port on one of the switches set in this group in order to be able to reach the web interface of any of the switches Group 2 to 20 These are the generic groups to be used fo...

Страница 19: ...ocking protocol by timestamping packets at the hardware level With PTPv2 the GigaCore can be part of the clock domain which is necessary for protocols such as AES67 The user can enable disable PTPv2 c...

Страница 20: ...erCon ports on the front with a maximum of 30W per port PoE compliant 4 5 2 MultiLinkX MultiLinkX alsoknownaslinkaggregation allowsyoutogathersever al links together in order to increase the available...

Страница 21: ...ish to modify B Enable or disable these port s C Select the priority for the port s D Apply your new parameters The priority of a port is used when the switch reaches the limit of its maximum output p...

Страница 22: ...e switch the user can select a pro le to export to a computer Then fromthesamecomputer theuserwillbeabletoloadthispro le into an empty slot on another switch Exchanging pro les between switches can be...

Страница 23: ...O THE WEB INTERFACE OF THE SWITCH YOU RE WORKING WITH ALSO PAY ATTENTION THAT THE IP ADDRESS THAT WILL BE RE LOADED WITH THE PROFILE DOESN T CONFLICT WITH AN OTHER IP INTHE NETWORK THE SWITCH SWEB INT...

Страница 24: ...Ds blink red Releasing the mode button while the LEDs are blinking red will reset the unit Be aware that releasing the mode button during the rst ve seconds before the LEDs start blinking red will can...

Страница 25: ...rthestatusLEDsstopped blinking red will cancel the operation Sometimes it is required to get more help with your device or applica tion There is a knowledge base available online that gets updated on...

Страница 26: ...notice Luminex its employees or appointed representatives will not be held responsible for any damages to software hardware or data howsoever arising as a direct or indirect result of the product s me...

Страница 27: ...EFFECTIVE RELIABLE ACCESSIBLE YOUR NETWORK SOLUTION FOR AUDIO VIDEO AND LIGHTING 27...

Страница 28: ...Slamstraat 13 3600 Genk Belgium T 32 11 812 189 info luminex be www luminex world...

Отзывы: