Unscrew the back plate using an  Umbraco 4mm. The leak 

proofing seal have a grease (OKS1110) applied to it – if this is wiped 

off, please make sure to replace it in order to make the housing leak 

proof. Each floodlight is delivered with one cable gland. Make sure to 

tighten all six M5 bolts. 

 

Your power cable should hold one wire for ground (GND) and two 

power wires – L and N. Dismantle these wires as shown in the figure: 

8 mm for each wire, and approx. 35 mm for the cable itself.  

 

The  RLX E  has three threaded M20x1.5  as well as two M25x1.5 

holes, each with a blind cap or a cable gland. Use a power cable with 

appropriate dimensions so that the cable gland connection is sealed 

when tightened.  

 

Conductor: Multi core, AWG 16–14 / 1.5-2,5 mm

 

To connect the cables to the spring–loaded conductor connection,

 

simply

 

press down a small screwdriver 

(preferably a slot screwdriver) as shown in the figure, and place the conductor in the spring cage. Repeat 

this for each conductor. For the RLX E, follow the circuit outlined below when carrying out the connections. 

 

Dim information: 

The RLX E floodlights can be dimmed with either a 1–10 VDC voltage controller, or by resistance (potmeter up to 100 

). For more information, please refer to the RLX E User Manual.

 

 

Note on coated print circuit board: 

 

In order to withstand extreme conditions even without the glass on, the print circuit boards in the RLX series are coated 

with a premium quality tough-gel. During the hardening process, this gel may generate some dew, which could be visible 

on the inside of the glass on brand new products. This is not a product failure, and the dew will disappear over time. 

 

 

DANGER! 

Electric shock risk, 100 – 305 VAC. Ensure that power is disconnected before carrying out any connections! 

 

 

Power connections to be installed in a professional and legal manner. 

 

Do not connect the RLX E floodlight on the same power circuit as floodlights using ballast units (such as high 

pressure sodium, metal halide or other high intensity discharge lamps).  

 

Make sure to replace unused cable glans with blind caps M20x1.5 / M25x1.5. Warranty will be voided if 

replaced cable glans / blind caps are not UV and weather resistant, –40°C to 80°C. In addition, it is the 

installer’s responsibility to ensure that cable and cable glands are appropriate for each other.  

 

Max 10 VDC 

Dim minus 

Dim plus 

To phase 

To neutral 

To ground 

100 – 305 VAC 