INSTALLATION GUIDE FOR
VPF4, VPF8, VPF12 LED SERIES
RETAIN THESE INSTRUCTION FOR FUTURE USE
One Lithonia Way, Conyers GA 30012 | 1.800.705.SERV (7378) |
| © 2020 Acuity Brands Lighting, Inc. All rights reserved.
Page
3
of
3
INSTALLATION PROCEDURE
1. Remove Luminaire from carton and check for damage
2. Remove Lens clamps via 8-32 screws, set aside
3. Remove Lens via 8-32 screw.
4. Remove LED Board Assembly by loosening (2) ¼ hex screws.
5. Unplug the LED Board Assembly from the Driver wires, set aside.
6. Mount fixture to surface using (4) ¼ bolts (not included).
7. Connect all supply wires in accordance with national and local electrical codes.
8. Plug the LED Board Assembly into the Driver wires.
9. Re-install LED Board Assembly using (4) ¼ hex screws. Do not over tighten
10. Re-Install Lens
11. Re-Install Lens Clamps
12. Energize and test.
Housing
End Cap
Lens Clamp
Lens
WARNING
(VPF8, VPF12)
- The main (white LED) circuit and the auxiliary circuit
(Nightlight) are to be wired to separate circuits that can’t be powered on simultaneously.