background image

02001026 
Rev 1 ECO 7062 

Operation Manual: 

LDD-100/150/250-XX-YY 

Page 12 of 13 

 

 

Optional RS-232 Protocol 

LDD-100/150/250-XX-YY-RS 

 
Refer to Figure 2, LDD-100/150/250 Outline Drawing for location of RS-232 Connector 
 
The RS232 interface for Lumina supplies has the following characteristics: 
 
 

Baud rate

: 9600 

 

Command format

:  ASCII characters terminated by carriage return 

 

Reply formats

:  ASCII characters terminated by carriage return 

 

Connection:

  9 Pin “D” Female (

Tx

: Pin 2, 

Rx:

 Pin 3, 

GND

: Pin 5) 

 
The interface supports programming the output current and power limit of the supply and 
reading back the output current and voltage.  The output can be turned on and off with a 
command as well.   
 

Command

 

 

Reply

   

Function

 

 
P

[email protected]

<cr> 

<cr>   

Program output current  to max rated output current 

 

 

 

 

 

xx.xx 

between 0 and 10.00 = 0 – Iout

max

 

 

 

 

 

 

 

(Note:  P

xx.xx

<cr> will also work) 

 
I<cr>  

 

xx.xx

<cr> Read 

output 

current 

xx.xx

 between 0  and 10.00 = 0  

Iout

max

 

 
V<cr>  

 

xx.xx

<cr> Read 

output 

voltage

 xxxx

 between 0 and 10.00 = 0 

 

 

 

 

 

to Vout

max

 

 
ON<cr>  <cr> 

 Enable 

supply 

output 

 

 
OFF<cr> 

 <cr> 

 Disable 

supply 

output 

 
Jhkhkh<cr> 

 ?<cr> 

 Response 

to 

unrecognized 

command 

 
Numbers sent to the supply should be in fixed point decimal format.  The numbers sent 
back will have four digits and a decimal point, but the resolution is limited to 12 bits and 
the accuracy is limited by the specifications of the supply.   
 
 

 

 

 

 

 

 

 

Содержание LDD-100

Страница 1: ...capability depending on the user s requirements LDD power supplies will deliver current as programmed into any load providing the voltage requirements of that load do not exceed the maximum rated vol...

Страница 2: ...ons 5 LDD 100 150 250 Interface 7 INSTALLATION AND OPERATION 9 Optional RS 232 Protocol 12 Tables and Figures LDD Laser Diode Power Supply Block Diagram 4 LDD 100 150 250 Outline Drawing 6 LDD 100 150...

Страница 3: ...This inverter boosts the input voltage to 400VDC In the process of boosting the input AC voltage the input AC current is adjusted so that is always in phase with the input AC voltage Without this pow...

Страница 4: ...EMI noise and a reduction in overall system heatsink requirements Output Circuit The output filter is a single stage RC filter designed to keep ripple and output noise very low Control Circuit The con...

Страница 5: ...sec 10 to 90 Full Current Current Regulation 0 5 of Maximum output current Temperature Drift 0 5 over temperature range after 30 minute warmup 0 5 in first 30 minutes Current Ripple 0 5 of maximum out...

Страница 6: ...02001026 Rev 1 ECO 7062 Operation Manual LDD 100 150 250 XX YY Page 6 of 13 Figure 2 LDD 100 150 250 Outline Drawing...

Страница 7: ...5 Vout Monitor output 0 10V 0 Voutmax The output voltage of the supply can be monitored by Vout Monitor 6 Iout Monitor output 0 10V 0 Ioutmax The output current of the supply can be monitored by Iout...

Страница 8: ...02001026 Rev 1 ECO 7062 Operation Manual LDD 100 150 250 XX YY Page 8 of 13 Figure 3 LDD 100 150 250 Interface...

Страница 9: ...ure 4 Although the user interface is typically designed by the user Lumina Power can provide any assistance necessary to modify interface program and monitor levels See Table 1 and Figure 3 for descri...

Страница 10: ...am Pin 7 A 0 10V signal results in 0 to Ioutmax as long as the rated compliance voltage of the driver is not exceeded 4 Operating the LDD a AC INPUT POWER CONNECTION Connect AC power connections to po...

Страница 11: ...output current as programmed 5 Monitoring LDD output and performance a Current Monitor Power supply output current can be monitored via pin 6 Iout Monitor A 0 10V signal will represent the output cur...

Страница 12: ...ply and reading back the output current and voltage The output can be turned on and off with a command as well Command Reply Function Pxx xx xx xx cr cr Program output current to max rated output curr...

Страница 13: ...Interface Schematic Pin Pin Name Functional Voltage Level Description 3 Interlock input Open OFF Connect to GND RUN The Interlock function can be connected to external interlock switches such as door...

Отзывы: