STEP 13. Connect Corresponding
LSP Wire Labeled “Line
1
Load” to Load
and
Turn Circuit Breaker Back On
WARNING: HIGH VOLTAGE. ENSURE MAIN BREAKER IS OFF. MAIN SERVICE LINES ARE ALWAYS LIVE.
AVERTISSEMENT: HAUTE TENSION. ASSUREZ-VOUS QUE LE DISJONCTEUR PRINCIPAL EST ÉTEINT. LES
CONDUCTEURS DE SERVICE PRINCIPAUX SONT TOUJOURS SOUS TENSION.
Tools
: Wire stripper and wire splice connector
NOTE:
All LSP wires labeled “Line # Load” must connect to a load wire via a
wire splice connector
(ensuring a tight connection) or be safely terminated with a Wire Connector. The LSP wire line number
must
match the line number used in the previous step (ex. “Line 3 Breaker” connects to a breaker and
“Line 3 Load” connects to that breaker’s load).
“
Line 1
Load
”
Load
Wire
“
Line 1 Breaker
”