![Lumiax Magic-E Series Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/lumiax/magic-e-series/magic-e-series_user-manual_1948513016.webp)
When the icon appears in the display interface, i
t
means that the parameters can be set.
Long press the
MENU
key for 1s, then icon flashes, press
OK
to change the parameter.
6.3.1 Low voltage protection
6.3.2 Low voltage reconnect
①
Battery voltage control
②
Battery
capacity control
Low voltage protection setting range
:
10.8
~
11.8V/21.6~23.6V
(default:
11.2/22.4/
V).
Low voltage reconnect setting range
:
11.4
~
12.8V/22.8~25.6V
(default :
11.8/23.6V
).
When the LCD shows as the left, press the
MENU
key for 1s, the icon
flashes, you can set the controller
low voltage protection.
's
When the LCD shows as the left, press the
MENU
key for 1s, the icon
flashes, you can set the controller low voltage reconnect.
's
When the LCD shows as the left, press the
MENU
key for 1s, the icon
flashes, you can press
OK
to clear the Bluetooth device password set by
the mobile app.
6.3
Parameters setting
1.Lithium Battery
1.Lithium Battery
2.Liquid, Gel and AGM Battery
2.Liquid, Gel and AGM Battery
When the battery type is lithium battery, the low-voltage protection
setting
range is 9.0-30.0V (default: 10.6V).
When the battery type is lithium battery, the low-voltage
reconnect
setting
range is 9.
6
-31.0V (default: 12.0V).
The low voltage protection of the controller can be divided into two
types: battery voltage control and capacity control.
11
.
0
~
11
.
6V/22.0~23.2V
11
.
1
~
11
.
7V/22
.
2
~
23
.
4V
11
.
2
~
11
.
8V/22
.
4
~
23
.
6V
11
.
4
~
11
.
9V/22
.
8
~
23
.
8V
11
.
6
~
12
.
0V/23
.
2
~
24
.
0V
Display
Low voltage protection range
T
he low voltage recovery voltage(LVR)
should be higher than the
low voltage protection
voltage(LVD) at least 0.6/1.2V, if you want to improve LVD, you should first improve LVR.
6.3.3
Clear Bluetooth Device Password
For device passwords, please refer to Bluetooth APP instructions.
13