2  SAFETY PRECAUTIONS

  WARNING: IMPORTANT: Before using Mattress System, read and adhere to the 

following safety precautions and warnings. Failure to do so could result in serious 
personal injury or damage to your Mattress System.

  WARNING: Caregivers should be sure to discuss Safety Information, Risks and 

Precautions and Contraindications with the patient (or the patient’s legal guardians) and 
the patient’s family.

Always consult your healthcare professional to determine safe methods most suitable for your 
individual abilities. Protect yourself, your attendant and Mattress System by having it serviced 
regularly. If you experience any malfunction, contact GF Tech Support at 1-770-368-4700 or your 
GF authorized distributor immediately, as a hazardous condition could result, causing personal 
injury or damage to your Mattress System.
Periodic inspection, adjustment and replacement of worn parts are necessary to provide years 
of excellent service. Refer to 

CARE AND MAINTENANCE

 section of this manual.

Maintenance MUST be performed by qualified personnel ONLY.

SIGNIFICANCE OF SAFETY STATEMENTS

Note the following special statements, used throughout this manual, and their significance:

  WARNING: Indicates a potential hazard situation or unsafe practice that, if not avoided, 

could result in death or serious personal injury.

  CAUTION: Indicates a potential hazard situation or unsafe practice that, if not avoided, 

could result in minor or moderate personal injury.

s

  NOTICE: Indicates a potential hazard situation or unsafe practice that, if not avoided, 

could result in product or property damage.

Info: Provides application recommendations or other useful information to ensure that 
you get the most from your product.

WARNINGS

  WARNING: Important! Read and understand these instructions before assembling or 

using the Select Mattress System. If you do not understand any part of these warnings, 
cautions or instructions, contact a healthcare professional for direction in the use of 
this product. If the Select Mattress System is not properly assembled, personal injury 
and damage to the Select Mattress System could result.

  WARNING: If components are damaged or missing, contact your GF authorized 

distributor immediately. DO NOT use substitute parts. Use only Lumex replacement 
parts. The use of non-Lumex replacement parts could cause personal injury, property 
damage, and void the warranty.

  WARNING: Unauthorized modification of your Mattress System could cause personal 

injury, property damage, and void the warranty.

  WARNING: The Mattress System has a minimum weight capacity of 88 lb (40 kg) and 

maximum weight capacity of 350 lb (158 kg), EVENLY DISTRIBUTED.

  WARNING: GF Health Products, Inc. assumes no responsibility for any damage or injury 

caused by improper assembly or use of this product.

Содержание SELECT LS200

Страница 1: ...l before operating your Mattress System Save this manual for future use The most current version of this manual can be found online at www grahamfield com SELECT SERIES LS200 ALTERNATING PRESSURE LOW...

Страница 2: ...ATTRESS INSTALLATION 10 PUMP INSTALLATION 10 6 OPERATING INSTRUCTIONS 11 PATIENT PLACEMENT AND NURSING CARE 11 OPERATION 11 SKIN CARE 11 INCONTINENCE DRAINAGE 11 GENERAL OPERATION 11 STATIC FUNCTION 1...

Страница 3: ...g your Mattress System INTENDED USE The Lumex LS200 Alternating Pressure Low Air Loss Mattress System is designed to aid in the treatment and prevention of pressure ulcers while optimizing user comfor...

Страница 4: ...result in death or serious personal injury CAUTION Indicates a potential hazard situation or unsafe practice that if not avoided could result in minor or moderate personal injury s NOTICE Indicates a...

Страница 5: ...bed frame labeling or with the manufacturer for dimensions prior to mattress placement WARNING Side Rails Patient Restraints Whether and how to use side rails or restraints is a decision that should b...

Страница 6: ...G Power Cord Ensure power cord is kept free from all pinch points and moving parts and is not trapped under casters Improper handling of the power cord can cause damage to the cord which may possibly...

Страница 7: ...l on cell therapy whereby the cell is split in two where the bottom cells do not deflate if the upper cells are completely deflated in order to provide extra protection and zero pressure comfort for t...

Страница 8: ...ront panel Pump rear view MATTRESS FEATURES Individual air cushion design for maximum pressure distribution Vented air cushion provides true low air loss therapy Cell on cell design for zero pressure...

Страница 9: ...flow from the hose connection ports Place in plastic bag for storage Mattress Check the air manifold for kinks or breaks Replace if necessary Twist open the CPR plug at the head of the mattress and di...

Страница 10: ...s 4 Ensure mattress is properly positioned with no gaps between mattress and bed frame or side rails 5 Secure straps on bottom of mattress to the bed frame PUMP INSTALLATION POWER Switch Hanger Pump R...

Страница 11: ...cularly in areas where incontinence and drainage occur Ensure linens under patient are not wrinkled Early intervention may be essential to preventing serious skin breakdown Incontinence Drainage Use m...

Страница 12: ...on selected mode default mode is ALTERNATE 3 Allow time for full mattress inflation 4 After the mattress is fully inflated the caregiver can transfer the patient to the mattress Note the mattress can...

Страница 13: ...lacing your hand under the patient buttocks between cells and bottom of mattress The patient should have at least 1 1 2 in 4 cm of clearance between the buttocks and the bottom of the mattress ALTERNA...

Страница 14: ...rom bottoming out Info The low pressure alarm is automatically disengaged for 45 minutes when control unit is first powered on to ensure no alarms are raised during initial inflation CPR DEFLATION WAR...

Страница 15: ...ch Support at 1 770 368 4700 for further information When you believe a component or part is not functioning properly immediately contact GF Tech Support at 1 770 368 4700 as a potentially hazardous c...

Страница 16: ...m hypochlorite solution to dilution of 1000 ppm or any EPA approved hospital grade disinfectant do not use phenol base cleaning solution INSPECTION SYSTEM CHECK OUT Check each of the following before...

Страница 17: ...odification alteration or misuse may lead to serious injury and or product damage and will void all applicable warranties SYMPTOM POSSIBLE CAUSE SOLUTION Air is pumping out from the control unit but m...

Страница 18: ...Voltage Frequency AC 110 120V 60 Hz Fuse Rating T1AL 250V Maximum Current 0 1A Classification Electrical Class II Type BF Not AP or AGP type Temperature Operation 59 F 104 F 15 C 40 C Storage Transpo...

Страница 19: ...ts 4 Accessories or parts not provided by GF 5 Charges by anyone for adjustments repairs replacement parts installation or other work performed upon or in connection with such products which are not e...

Страница 20: ...LS200 INS LAB RevB17 20 11 EMC RELATED NOTIFICATION...

Страница 21: ...LS200 INS LAB RevB17 21...

Страница 22: ...LS200 INS LAB RevB17 22...

Страница 23: ...roduction 3 L Low pressure alarm 14 M Mattress cleaning 15 Mattress installation 10 N Notices 6 NOTICE statement significance 4 Nursing care 11 O Operating instructions 11 P Patient Placement 11 Pump...

Страница 24: ...e product information can be found on our website www grahamfield com 2017 GF Health Products Inc All Rights Reserved Graham Field and Lumex are trademarks of GF Health Products Inc GF Health Products...

Отзывы: