background image

 

English 

26

 

Iris Limit 

1. F1.6 

2. 

F2.2 

3. F3.2 

4. F4.5 

5. F6.3 

6. F9 

7. F13 

8. F18

 

Max. limit value of iris 

WDR 

1. 

Off 

2. 1 

3. 2 

4. 3

 

5. 4

 

6. 5

 

WDR settings 

Anti Flicker 

1. 50Hz 

2. 60Hz 

1. 

Off

 

Set the image sync 

frequency during 

capturing 

White 

Balance 

Mode 

1. 

Auto 

2. Indoor 

3. Outdoor 

4.  One Push WB 

5. ATW 

6. Sodium 

Lamp 

7. Manual 

8. 3000K 

9. 4300K 

10. 5000K 

11. 6500K 

12. 8300K 

13. WideAuto 

Select the color 
temperature mode 

1.  4000k ~ 7000k 

2. 3200k 

3. 5800k 

4.  1700k ~ 10000k 

5.  1700k ~ 10000k 

6. 2800k 

7. Custom 

8. 3000K 

9. 4300K 

10. 5000K 

11. 6500K 

12. 8000K 

13.  3000k ~ 7000k 

One Push 

Trigger 

ENTER 

One push trigger 

Manual Red 

0~

 C

~60  

Adjustable when the white 
balance mode is set to 

Manual

Содержание VC-A52S

Страница 1: ... Camera PTZ Video Camera Installation Guide English Important To download the latest version of Quick Start Guide multilingual user manual software or driver etc please visit Lumens https www MyLumens com support ...

Страница 2: ...ontrol 21 5 2 Setting Menu 22 Chapter 6 Descriptions of Major Functions 31 6 1 I would like to switch to VC A51S 31 6 2 I would like to save the current lens position data 31 6 3 I would like to clear the saved position data 31 6 4 I would like to turn on the back light compensation function 31 6 5 I would like to adjust the shooting angle of the lens 31 6 6 I would like to hide the preset image s...

Страница 3: ...ange the camera direction 33 6 14 I would like to display the current status 33 6 15 I would like to reset to the original setting 33 Chapter 7 DIP switch setting 34 7 1 DIP SWITCH 34 7 2 RS 422 Connection 35 Chapter 8 Troubleshooting 37 Supplier s Declaration of Conformity 47 CFR 2 1077 Compliance Information 39 ...

Страница 4: ... product Lumens Digital Optics Inc hereby reserves the right to make changes to product specifications without prior notice The information in this file is subject to change without prior notice To fully explain or describe how this product should be used this manual may refer to names of other products or companies without any intention of infringement Disclaimer of warranties Lumens Digital Opti...

Страница 5: ...pening or removing covers may expose you to dangerous voltages and other hazards Refer all servicing to licensed service personnel 1 11 Unplug this product from the wall outlet and refer servicing to licensed service personnel when the following situations happen If the power cords are damaged or frayed If liquid is spilled into the Product or the Product has been exposed to rain or water 2 Instal...

Страница 6: ...ound to comply with the limits for a Class A digital device pursuant to Article 15 J of FCC Rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Digital App...

Страница 7: ... 6 Chapter 2 Package Contents VC A51S Instruction for installation Remote Control Power Cord Power Adapter RS 422 Connector Appearance may vary depending on country region Metal Plate A Metal Plate B M3 Screws ...

Страница 8: ...ection 8 RS 232 Output 9 RS 232 Input 10 HDMI Output 11 3G SDI Output 3 2 Description of LED indicator 3 2 1Power 3 2 1 1 No Light Power off 3 2 1 2 Green light In use 3 2 1 3 Flickering green Signal from the remote control is received the indicator flickers every 0 5 second 3 2 2Standby 3 2 2 1 Orange In standby mode 3 2 2 2 No Light Power on Front View Back View ...

Страница 9: ... box are complete or not Please contact the supplier for any shortage and make sure to keep the accessories in the box intact 4 1 3 Please choose a proper place for installation of camera in advance Please determine an installation place according to the following requirements 4 1 1 1 Confirm the position for the object to be captured 4 1 1 2 Confirm whether the camera is set at a proper distance ...

Страница 10: ...e the normal vertical and horizontal operation of the machine 4 2 2 I would like to install VC A51S on the ceiling 4 2 2 1 Prepare for the parts and equipment required during the installation 1 Accessories of VC A51S in the box metal plates A B M3 screw silver x 8 black x 2 2 Screw for locking on ceiling mounted hanger x 4 3 Drilling machine screw driver ladder 4 2 2 2 Camera Size Length x Width x...

Страница 11: ...English 10 4 2 2 3 Max rotation dimension of camera ...

Страница 12: ...English 11 4 2 2 4 Size Diagram 1 Metal plate A machine side Metal plate A machine side Metal plate A locking screw ...

Страница 13: ...English 12 2 Metal plate B ceiling side Metal plate B locking screw Metal plate B locking bolt Metal plate B ceiling side M3 threaded hole M3 threaded hole M3 threaded hole ...

Страница 14: ...English 13 3 Bottom of machine ...

Страница 15: ... lens 3 The machine including metal plates is weighed at about 2 5 kg If it is to be installed on the ceiling please use the hanger that has obtained UL security approval to prevent the machine from falling down 4 Please check whether the camera is installed securely on a regular basis 4 2 2 6 Installation steps 1 Please adjust resolution on DIP switch at first Remark Please refer to Chapter 7 DIP...

Страница 16: ...ained UL security approval 2 Please reserve the hole for the connecting wires of the camera 4 Combine the metal plate A and the metal plate B 1 Push the metal plate A up to the ceiling and then to the right to latch the metal plate B 2 And then secure with 2 M3 silver screws and 1 M3 black screw black screw ...

Страница 17: ... the connecting wires from the camera 2 Uninstall the camera together with the ceiling loosen the three screws that fix the metal plates A and B and push to the left to remove the machine 3 Then remove the screws on the hanger and the machine ...

Страница 18: ...English 17 4 3 Connecting the device 4 3 1 Image Output 4 3 1 1 Connecting to a HDTV computer monitor DVI HDMI cable Monitor or HDTV ...

Страница 19: ...English 18 4 3 1 2 Connecting to an HDTV 3G SDI SDI Cable ...

Страница 20: ...3 2 Controlling VCs with the computer 4 3 2 1 Connecting to one computer for connection between VCs RS 232 in out Remark With RS 232 in out at most 7 VCs can be connected 4 3 2 2 RS 232 pins definition instructions ...

Страница 21: ...h 20 4 3 2 3 Connecting to one computer for connection between VCs RS 422 Remark With RS 422 at most 7 VCs can be connected Remark Please refer to 7 2 RS 422 connection for the RS 422 connection instructions ...

Страница 22: ...l length Focus Auto Auto Focus Freeze Freeze the screen Home Enter Go back to the main page Execute Info Status information L R Direction Set L R Direction Normal Menu Display OSD menu Mirror Rotate the image OFF Mirror Flip Rotate Pan Tilt Reset Clear the Pan Tilt setting Picture Switch image effect OFF Neg B W Power Power Switch Preset Appoint an ID 0 9 to save the current position data Reset Ap...

Страница 23: ...setting Exposure Comp On Off AE Level Exposure Comp Level 6 C 4 The value can be adjusted only after Exposure Comp is activated Spot Light On Off Adjustable when the Exposure mode is set to Full Auto or Shutter Pri Spot Light Position X 0 8 Y 0 6 The value can be adjusted after Spot Light is activated Shutter Pri 60 30 mode 50 25 mode Adjustable when the Exposure mode is set to Shutter Pri 1 10000...

Страница 24: ...1 100 1 90 1 75 1 60 1 50 1 30 1 25 1 15 1 12 1 8 1 6 1 4 1 3 1 2 1 2 1 1 1 1 Iris Pri 1 F1 6 2 F2 3 F2 2 4 F2 7 5 F3 2 6 F3 8 7 F4 5 8 F5 4 9 F6 3 10 F7 8 11 F9 12 F11 13 F13 14 F16 15 F18 Adjustable when the Exposure mode is set to Iris Pri ...

Страница 25: ... 26 dB 15 28 dB 16 30 dB Adjustable when the Exposure mode is set to Manual Manual Speed 60 30 mode 50 25 mode Manually set the shutter 1 10000 1 10000 1 5000 1 5000 1 3000 1 3000 1 2500 1 2500 1 2000 1 1750 1 1500 1 1250 1 1000 1 1000 1 725 1 600 1 500 1 425 1 350 1 300 1 250 1 215 1 180 1 150 1 120 1 120 1 100 1 100 1 90 1 75 ...

Страница 26: ...anual Iris 1 F1 6 2 F2 3 F2 2 4 F2 7 5 F3 2 6 F3 8 7 F4 5 8 F5 4 9 F6 3 10 F7 8 11 F9 12 F11 13 F13 14 F16 15 F18 Manually set the iris Gain Limit 1 8 dB 2 10 dB 3 12 dB 4 14 dB 5 16 dB 6 18 dB 7 20 dB 8 22 dB 9 24 dB 10 26 dB 11 28 dB 12 30dB Max limit value of electron gain ...

Страница 27: ...ite Balance Mode 1 Auto 2 Indoor 3 Outdoor 4 One Push WB 5 ATW 6 Sodium Lamp 7 Manual 8 3000K 9 4300K 10 5000K 11 6500K 12 8300K 13 WideAuto Select the color temperature mode 1 4000k 7000k 2 3200k 3 5800k 4 1700k 10000k 5 1700k 10000k 6 2800k 7 Custom 8 3000K 9 4300K 10 5000K 11 6500K 12 8000K 13 3000k 7000k One Push Trigger ENTER One push trigger Manual Red 0 C 60 Adjustable when the white balanc...

Страница 28: ...gs 3D NR 1 Off 2 LOW 3 Typ 4 Max 5 Auto 3D dynamic noise reduction settings Image Mode 1 Mode1 2 Mode2 3 Mode3 4 Mode4 5 Mode5 6 Mode6 7 Custom The user may customize his her desired image mode Image Mode Load 1 Mode1 2 Mode2 3 Mode3 4 Mode4 5 Mode5 6 Mode6 Adjustable when the Image mode is set to Custom After selected the corresponding Image mode parameters will be read and applied to Custom Satu...

Страница 29: ...mode is set to Custom Black Level 1 Off 2 Type 1 3 Type 2 4 Type 3 Shadow details and transparency adjustment adjustable when the Image mode is set to Custom Pan Tilt Zoom Pan Tilt Limit On Off Turn on off the angle limit setting Pan Right Limit 0 170 Limit the right angle Pan Left Limit 170 0 Limit the left angle Tilt UP Limit 0 90 Limit the upward angle Tilt Down Limit 30 0 Limit the downward an...

Страница 30: ...r AF is triggered AF Frame Full Frame Center AF frame setting when central area was set as AF frame focusing will be on the center of the screen When Full Frame was set as AF frame focusing will be calculated based on the full screen System Video Type SDI Select video output type DVI I Prompt On Off Turn on off the prompt information on the display IR Receive On Off Turn on off the infrared recept...

Страница 31: ...ssion speed of the control signal VISCA Address 0 7 Pelco D Address 1 C 255 The Protocol set to Pelco D allows the camera ID address to be assigned Output Mode 1 1920x1080 60p 2 1920x1080 50p 3 1920x1080 30p 4 1920x1080 25p 5 1920x1080 60i 6 1920x1080 50i 7 1280x720 60p 8 1280x720 50p 9 1280x720 30p 10 1280x720 25p 11 1080 59 94p 12 1080 59 94i 13 1080 29 97p 14 720 59 94p 15 720 29 97p Choose the...

Страница 32: ... data ID shall be a digit 0 9 Use VISCA command to clear position data stored in 0 127 6 4 I would like to turn on the back light compensation function 1 Press Back Light on the remote control to turn on or turn off the back light compensation 6 5 I would like to adjust the shooting angle of the lens 1 Press Tilt or Tilt on the remote control to adjust the angle upward or downward 2 Press Pan or P...

Страница 33: ...automatically 6 8 2 Manual focus 1 Press MF on the remote control to turn on the manual focus function 2 Press Focus or Focus to adjust 6 9 I would like to adjust the AF sensitivity Triggering speed of focus The higher the speed is the faster focus is triggered To shoot fast moving objects AF Sensitivity can be set to High or Medium which is applicable to quick focus When the environment is too da...

Страница 34: ...p Mirror Flip 6 13 I would like to change the camera direction 1 Press L R Direction Set on the remote control to switch L R Direction Off Normal 6 14 I would like to display the current status 1 Press Info on the remote control to display the current status information 6 15 I would like to reset to the original setting 1 Press MENU to activate the setting menu 2 Press or to select System 3 Press ...

Страница 35: ...TCH 7 1 1 OUTPUT Switch 7 1 2 IR SELECT ID Setting 1 2 3 Setting Function Descriptions 0 1920x1080 60p 1 1920x1080 50p 2 1920x1080 30p 3 1920x1080 25p 4 1920x1080 60i 5 1920x1080 50i 6 1280x720 60p 7 1280x720 50p 8 1280x720 30p 9 1280x720 25p A 1080 59 94p B 1080 59 94i C 1080 29 97p D 720 59 94p E 720 29 97p F Reserved ...

Страница 36: ...English 35 7 2 RS 422 Connection 7 2 1 RS 422 Pin Description 7 2 2 Use RS 422 Connection 1 Hold the two sides of RS 422 connector and pull out in the direction shown by the arrow in the figure below ...

Страница 37: ...WG Nos 28 to 18 and insert it into the connector hole then use flat screw driver to fix it 3 Insert the wired RS 422 connector back to the camera Now the connection is completed Note When RS 422 connection is being used do not use RS 232C connection ...

Страница 38: ...display supports the output resolution in general the resolution is 1080p60 1080i60 720p60 4 Replace the cables and make sure they are not faulty 3 VC A51S image is severely delayed Please use 1080p or 720p 60 50 Hz signals rather than 25 30 Hz signals 4 Not working after changes to DIP Switch setting After completing DIP Switch setting unplug and reconnect the power cord and turn on the machine t...

Страница 39: ...ure the firmware version is the latest one The steps to check version is as follows 1 1 Press MENU on the remote control 1 2 Choose Status 1 3 Go to Page 5 of System 1 4 Make sure the firmware version is correct 2 Make sure the connection is correct RS 232 422 Input 3 Please confirm OSD menu System Control Protocol setting 7 The device cannot be controlled with RS 232 RS422 1 Make sure the connect...

Страница 40: ...ormation Supplier Lumens Integration Inc 4116 Clipper Court Fremont CA 94538 United States e mail support mylumens com FCC Compliance Statement This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired...

Отзывы: