background image

 

 

English - 

23

 

 

Output Mode 

1. 

1080p/60 

2. 1080p/59.94 

3. 1080p/50 

4. 1080p/30 

5. 1080p/29.97 

6. 1080p/25 

7. 1080i/60 

8. 1080i/59.94 

9. 1080i/50 

10. 720p/60 

11. 720p/59.94 
12. 720p/50

 

Set output resolution 

Protocol 

Protocol V

Protocol PD

 

Protocol V: VISCA 
Protocol PD: PELCO D 

Factory Reset 

On / 

Off

 

Resume the factory default setting 

FW Upgrade 

On / 

Off

 

Upgrade Firmware 

Status  

 

Display the current setting status 

 

Содержание VC-A20P

Страница 1: ...A20P HD Camera Installation Guide English Important To download the latest version of Quick Start Guide multilingual user manual software or driver etc please visit Lumens http www MyLumens com support php ...

Страница 2: ...would like to clear the saved position data 24 6 4 I would like to turn on the back light compensation function 24 6 5 I would like to adjust the shooting angle of the lens 24 6 6 I would like to zoom in out images 24 6 7 I would like to adjust the focal length 24 6 8 I would like to adjust the AF speed 24 6 9 I would like to set the image mode 25 6 10 I would like to freeze images 25 6 11 I would...

Страница 3: ... product Lumens Digital Optics Inc hereby reserves the right to make changes to product specifications without prior notice The information in this file is subject to change without prior notice To fully explain or describe how this product should be used this manual may refer to names of other products or companies without any intention of infringement Disclaimer of warranties Lumens Digital Opti...

Страница 4: ... Camera has been exposed to rain or water 2 Installation 2 1 For security considerations please make sure the standard hanging rack you bought is in line with UL or CE safety approbations and installed by technician personnel approved by agents 3 Storage 3 1 Do not place the HD Camera where the cord can be stepped on as this may result in fraying or damage to the lead or the plug 3 2 Never push ob...

Страница 5: ...led Digital Apparatus ICES 003 of Industry Canada Cet appareil numerique respecte les limites de bruits radioelectriques applicables aux appareils numeriques de Classe A prescrites dans la norme sur le material brouilleur Appareils Numeriques NMB 003 edictee par l Industrie EN55022 CE Radiation Warning This product is intended for use in a commercial industrial or educational environment It is not...

Страница 6: ... 5 Chapter 2 Package Contents VC A20P Instruction for installation Remote control Power cord Power Adapter RS 422 Connector Appearance may vary depending on country region Metal Plate A Metal Plate B M3 Screws ...

Страница 7: ... 232 output 11 RS 232 input 12 RS 422 Connection 13 Audio In 14 C VIDEO output 15 Camera Address Selectors 3 2 Description of LED indicator Status Power Srandby Startup in progress Green light Orange light In use Green light No indicator In standby mode No indicator Orange light Signal from the remote control is received Green light flickers it flickers every 0 5 second No indicator Front View Bac...

Страница 8: ...se a proper place for installation of VC A20P in advance Please determine an installation place according to the following requirements 4 1 1 1Confirm the position for the object to be captured 4 1 1 2Confirm whether the VC A20P is set at a proper distance from other light sources 4 2 Instruction for installation 4 2 1 I would like to install VC A20P on the desk 4 2 1 1 Precautions for installatio...

Страница 9: ...quired during the installation 1 Accessories of VC A20P in the box metal plates A B and M3 screw x 7 2 Screw for locking on ceiling mounted hanger x 4 3 Drilling machine screw driver ladder 4 2 2 2 Camera Size Length x Width x Height 174 x 173 8 x 182 7 mm Weight 1 8 Kg 4 2 2 3 Max rotation dimension of camera ...

Страница 10: ...English 9 4 2 2 4 Size Diagram 1 Metal plate B ceiling side Metal plate B locking screw Metal plate B locking bolt Metal plate B ceiling M3 threaded hole M3 threaded hole M3 threaded hole ...

Страница 11: ...English 10 2 Metal plate A machine side Metal plate A machine side Metal plate A locking screw ...

Страница 12: ...distance of more than 1 meter away from the object to be captured Please adjust for a best distance according to the magnification of the lens 3 The machine including metal plates is weighed at about 2 5 kg If it is to be installed on the ceiling please use the hanger that has obtained UL security approval to prevent the machine from falling down 4 Please check whether the camera is installed secu...

Страница 13: ...al plate A on the machine base with 4 M3 screws 3 Lock the metal plate B on ceiling mounted hanger Caution 1 Please use the hanger that has obtained UL security approval 2 Please reserve the hole for the connecting wires of the camera 4 Combine the metal plate A and the metal plate B 1 Push the metal plate A up to the ceiling and then to the right to latch the metal plate B 2 Fix with 3 M3 screws ...

Страница 14: ...a together with the ceiling loosen the three screws that fix the metal plates A and B and push to the left to remove the machine 3 Then remove the screws on the hanger and the machine 4 3 Connecting devices 4 3 1 Image output 4 3 1 1 Connecting to a HDTV computer monitor DVI DVI cable Monitor or HDTV ...

Страница 15: ...et Remark 1 VC A20P can be used with browsers Lumens VMS VLC and QuickTime after it is connected to the Internet Remark 2 For use of Lumens VMS please refer to the User Manual for VMS Software 4 3 1 4 Connecting AUDIO IN C Video Cable TV Router or Hub Network cable Microphone ...

Страница 16: ...Setup before use Connect DVI output to the screen Press MENU on the Remote Control to display the OSD menu Shift down to Ethernet to modify and confirm the IP address DHCP Enable disable the dynamic host configuration protocol IP Address Confirm or modify the IP address of VC A20P Subnet mask 255 255 255 0 Gateway Preset 192 168 100 1 Remark Please modify the above settings based on the LAN settin...

Страница 17: ...lt IP address Enter administrator s account and password Account admin Default Password 9999 Default Subnet mask 255 255 255 0 Gateway Preset 192 168 100 1 Remark 1 For details please refer to Chapter 7 Network Function Settings Description Remark 2 In addition to browsers other software such as Lumens VMS VLC and QuickTime can be used for operation Remark 3 For operation of Lumens VMS please down...

Страница 18: ...ngth Focus Auto Auto focus Freeze Freeze the screen Home Enter Go back to the main page Execute Info Status information L R Direction Set L R Direction Normal Menu Display OSD menu Mirror Rotate the image OFF Mirror Flip Mirror Flip Pan Tilt Reset Clear the Pan Tilt setting Picture Switch image effect OFF NEG Black White Power Power switch Preset Appoint an ID 0 9 to save the current position data...

Страница 19: ...Pri 4 Manual 5 White Board 6 Smooth Auto Exposure mode setting Exposure_ Comp On Off AE Level Exposure_ Comp Level 6 0 5 The value can be adjusted only after Exposure_ Comp is activated Shutter Pri 60 30 mode 50 25 mode Shutter priority setting 1 10000 1 10000 1 5000 1 5000 1 3000 1 3000 1 2500 1 2500 1 2000 1 1750 1 1500 1 1250 1 1000 1 1000 1 725 1 600 1 500 1 425 1 350 1 300 1 250 1 215 1 180 1...

Страница 20: ...B 7 12 dB 8 14 dB 9 16 dB 10 18 dB 11 20 dB 12 22dB 13 24dB 14 26 dB 15 28 dB 16 30 dB Manually set the gain Manual Speed 60 30 mode 50 25 mode Manually set the shutter 1 10000 1 10000 1 5000 1 5000 1 3000 1 3000 1 2500 1 2500 1 2000 1 1750 1 1500 1 1250 1 1000 1 1000 1 725 1 600 1 500 1 425 1 350 1 300 1 250 1 215 1 180 1 150 1 120 1 120 1 100 1 100 1 90 1 75 1 60 1 50 1 30 1 25 1 15 1 12 1 8 1 6...

Страница 21: ...20 4 Manually set the iris Gain Limit 1 8 dB 2 10 dB 3 12 dB 4 14 dB 5 16 dB 6 18 dB 7 20 dB 8 22dB 9 24dB 10 26 dB 11 28 dB 12 30dB Max limit value of electron gain Iris Limit 1 F1 8 2 F2 1 3 F2 5 4 F3 0 5 F3 6 6 F4 3 7 F5 1 8 F6 1 9 F7 2 10 F8 6 11 F10 2 12 F12 1 13 F14 4 14 F17 15 F20 4 Max limit value of iris WDR 1 Off 2 1 3 2 4 3 5 4 6 5 WDR settings ...

Страница 22: ...Set the picture effect Sharpness 0 C 15 Adjust the sharpness of the image 2D NR 1 Auto 2 Off 3 1 4 2 5 3 6 4 7 5 2D noise reduction settings 3D NR 1 Off 2 Low 3 Typ 4 Max 5 Auto 3D dynamic noise reduction settings Image Mode 1 Mode 1 2 Mode 2 3 Mode 3 4 Mode 4 5 Mode 5 6 Mode 6 7 Custom The user may customize his her desired image mode Image Mode Load 1 Mode 1 2 Mode 2 3 Mode 3 4 Mode 4 5 Mode 5 6...

Страница 23: ...etting when central area was set as AF frame focusing will be on the center of the screen When Full Frame was set as AF frame focusing will be calculated based on the full screen Ethernet DHCP On Off Enable Disable DHCP setting using left and right arrow keys and press ENTER to apply setting IP Address 192 168 100 150 Press ENTER to modify the items select the item to be modified using left and ri...

Страница 24: ... 7 1080i 60 8 1080i 59 94 9 1080i 50 10 720p 60 11 720p 59 94 12 720p 50 Set output resolution Protocol Protocol V Protocol PD Protocol V VISCA Protocol PD PELCO D Factory Reset On Off Resume the factory default setting FW Upgrade On Off Upgrade Firmware Status Display the current setting status ...

Страница 25: ...lt on the remote control to adjust the angle upward or downward 2 Press Pan or Pan on the remote control to adjust the angle to right or left 3 Press Pan Tilt Reset on the remote control to reset the angle to the center point 6 6 I would like to zoom in out images 6 6 1 Adjust image size 1 Press Fast on the remote control to zoom in images 2 Press Fast on the remote control to zoom out images 6 6 ...

Страница 26: ...t 6 9 I would like to set the image mode 1 Press Picture on the Remote Control to switch Off Neg B W 6 10 I would like to freeze images 1 Press Freeze on the remote control to freeze the current image on the display 6 11 I would like to rotate the image 1 Press Mirror on the Remote Control to switch Off Mirror Flip Mirror Flip 6 12 I would like to change the camera direction 1 Press L R Direction ...

Страница 27: ...e use Internet Explorer 8 or higher as the website browser 1 Open the browser and enter the URL of VC A20P in the address bar e g http 192 168 100 150 default IP address 2 Enter administrator s account and password to get started Account admin Default Password 9999 Default 3 Remark 1 WebPlugin must be installed before the first use Please install the program after downloading according to instruct...

Страница 28: ...owser and VMS other RTSP methods can be used for connection such as VLC and Quick Time RTSP connection address rtsp VC IP Address 8557 h264 1 Open the software to enter URL rtsp 192 168 100 150 8557 h264 7 1 5 Use RTMP connection Support RTMP connection If RTMP server is set up RTMP connection function can also be opened Please log into VC A20P webpage to change RTMP of network setting as describe...

Страница 29: ...ese and Simplified Chinese Remember password Remember the password so that you do not need to type it next time Login Log into the administrator screen on the website 7 2 2 Preview Screen 1 Information about image encoding form and resolution 2 Rotate camera angle 3 Zoom in out 4 Preview window 5 Power off VC A20P 6 Apply Set preset 7 Switch to Full Screen 8 Logout 1 2 3 4 5 6 7 8 ...

Страница 30: ...e password and permission of new account Delete Delete new account Remark Reference for User Permissions User Type Admin Operator Viewer View images Y Y Y Settings Y Y N User accounts management Y N N 7 2 4 Settings Video Setting 1 Camera name Change camera name on this page 2 Select rate and encoding 3 Storage setting for advanced settings see 7 2 5 Settings Advanced Video Setting 1 2 3 4 1 2 3 ...

Страница 31: ...s available HIGH_QUALITY Higher image quality can be obtained SVC SVC opened encoding mode is applicable to RTSP series flow of 8601 8602 8603 and 8604 ports different refresh rate for different ports See remark 4 Encode Profile Encoded Information 5 Preset Save Remark SVC connection address rtsp VC IP Address Port h264 1 60Frame rtsp VC IP Address 8557 h264 e g rtsp 192 168 100 150 8557 h264 2 30...

Страница 32: ...djust camera settings Please refer to 7 2 7 Settings Advanced Camera Setting 5 Preset Save 7 2 7 Settings Advanced Camera Setting 1 Exposure Mode Select exposure mode Exposure Comp Level Select exposure compensation level Gain Adjust gain restriction Iris Iris setting WDR WDR settings 1 2 3 4 5 4 1 2 3 ...

Страница 33: ...D noise reduction settings 3 3D NR 3D dynamic noise reduction settings 4 Image Mode The user may customize his her desired image mode 5 Image Mode Load Adjustable when Image Mode is set to Custom similar to OSD 6 Black Level Adjustable when Image Mode is set to Custom similar to OSD 7 Gamma Adjustable when Image Mode is set to Custom similar to OSD 8 Skin Tone Skin tone settings adjustable when Im...

Страница 34: ...le rate 4 Preset Save 7 2 10Settings Date Time Setting 1 Current camera date and time 2 Set the Time Manual setting synchronous computer time synchronous SNTP server time time of automatic adjustment of daylight saving 3 Preset Save Remark SNTP server address Please change in network setting 1 2 3 4 1 3 2 ...

Страница 35: ...en menu see 5 2 Setting Menu 2 Set RTMP Set connection address of RTMP depending on RTMP Server setting 3 Set RTSP Enable Disable Multicast Remark It is suggested to enable Multicast when the number of users online watching the live image simultaneously is more than 4 4 Set SNTP Set SNTP Server IP 5 Set HTTP port The default Port value is 80 Remark Change of setting is available only when DHCP fun...

Страница 36: ...1 OUTPUT Switch Output Mode Setting Output Mode Setting 1920x1080 60p 1920x1080 50p 1920x1080 30p 1920x1080 25p 1920x1080 60i 1920x1080 50i 1280x720 60p 1280x720 50p 1080 59 94p 1080 59 94i 1080 29 97p 720 59 94p 8 1 2 IR SELECT ID Setting 1 2 3 8 1 3 Camera Address Selector Setting Function Descriptions 0 7 ID 0 7 8 9 Reserved ...

Страница 37: ...ff ON On DIP 3 Communication baud rate selector OFF 9600 ON 38400 DIP 4 Reserved 8 2 RS 422 Connection 8 2 1 RS 422 Pin Description Pin NO Function 1 RXD OUT 2 RXD OUT 3 TXD OUT 4 TXD OUT 5 GND 6 RXD IN 7 RXD IN 8 TXD IN 9 TXD IN Note Please connect IN to OUT when connecting to SONY products For non SONY products it may be necessary to connect IN to OUT ...

Страница 38: ...y the arrow in the figure below 2 Peel off a section of copper wire AWG Nos 28 to 18 and insert it into the connector hole then use flat screw driver to fix it 3 Insert the wired RS 422 connector back to the camera Now the connection is completed Note When RS 422 connection is being used do not use RS 232C connection ...

Страница 39: ... the setting 5 VC A20P cannot be operated by remote control 1 Please confirm if the Camera Select on the remote control can be used together with the IR Select on VC A20P 2 Please prevent VC A20P from direct sunshine 3 Make sure the energy saving bulb and the IR touch screen are as far as possible in order to avoid interference 4 When several VC A20P are connected in the same area the operation of...