 INSTALLATION:

 

 

 

IMPORTANT: Cable should be laid inside armoured conduit or piping to protect from water-logging, chemicals found in soil 
and damage. If buried, it should be buried to at least 0.5m below ground to reduce damage risk. If this method is not used, 
cable warranty will be void. 
 
Always test bollards prior to installation, especially if concreting in place. 

 

1.

 

Push the anchor bar through the pre-drilled holes at the base of the tube and secure in 
place with the 2 x nuts provided. 

2.

 

Prepare a mounting hole in the desired location to allow for a tube depth of approx. 
400mm  (can  vary  depending  on  the  required  height  above  ground).  Ensure  the 
diameter of the hole is at least  400mm to accommodate the anchor bar & tube and 
allow  for  concrete  /  earth  to  be  added 

  Concrete  installation  recommended.  TIP: 

Carry out placement check, ensuring the photocell located  in the tube will be facing 
the correct direction for optimum light sensitivity. 

3.

 

IF USING CABLE GLAND:

 Drill out a 20mm hole at the desired location in the 

tube  for  cable  exit  (just  above  ground  height  is  recommended).  Remove  the  nylon 
locking nut from the gland. Push the thread through the drilled hole from the outside, 
ensuring the rubber o-ring is on the outside of the tube, and secure in place with the 
locking nut inside the tube. Remove the domed cap, push the cable through the  cap, 
threaded gland and then the locking nut. Secure the cap in place, screwing clockwise, 
when  the  desired  length  of  cable  has  been  pulled  through  to  reach  the  connecter 
inside the tube with plenty of slack.  

4.

 

WITHOUT CABLE GLAND:

 Cable will simply enter the underside of the tube.  

5.

 

Carefully lay down the bollard on a soft, protective surface e.g. cloth / cardboard and 
connect the mains cable to the bollard via the In-line connector provided (see 
diagram). Alternative, change the connector to a waterproof, multi-way junction box. 

6.

 

Check that the supply wires are correctly identified, the connections are tight and that 
there are no loose strands. Also check that the connector is fully tightened and sealed. 

7.

 

Push the cable up as high up inside the tube as possible and mount in position, ensuring 
the photocell is facing the correct direction and that the cable connection will not be 
covered with the mounting material (earth / concrete).  

8.

 

Test prior to setting in place for easier access to cable in case of issues - the photocell will need 
to be covered for daytime testing which has a short delay of <5 secs.. 

9.

 

Mount the Tube into the final location using supports to hold the fitting upright and checking that 
it is straight with a spirit level. Concrete or earth must cover the anchor bar and at least 200-
300mm above. 

 

 

 

 WIRING:

  

 

Please Note: For models with a photocell, the photocell is pre-wired within the head, not the 
connector block at the base of the tube. Should the photocell become faulty, please contact us 
for further information. 

   

In-line Connector 

1.

 

Unscrew and remove the cap and thread from the open end of the connector 

2.

 

Unscrew cap from cable end of connector and move up the cable 

3.

 

Pull the red, rubber grommet up the cable to the label (approx.) 

4.

 

Pull centre sleeving up the cable pushing the cable downward to reveal the terminal block 

5.

 

Loosen the 3 screws at the open edge of the connector block. 

6.

 

Place end cap and thread over your prepared mains cable and then wire into the connector block 

accordingly, fastening the 3 screws to secure the cables in place. Ensure there are no loose strands 
and that the wire is clamped, not the rubber sheath. Each terminal is marked with the Live, 
Neutral or Earth Symbol, with the screw threaded towards the relevant terminal. 

7.

 

Always check wires are connected to the correct wire / terminal. 

8.

 

Reassemble the in-line connector: 

a.

 

Pull the sleeving back over the terminal 
block, then pull red, rubber grommet back 
inside the flexi-end of sleeving, then 
replace end cap securely (clockwise 

 

turning end cap 

 DO NOT TWIST 

CABLE). 

b.

 

Reattach the thread to the sleeving, fully 
encasing the terminal block and then the 
end cap (DO NOT TWIST CABLE) 

 

 

Cap 

Lock Nut 

O-Ring 

CONNECTIONS:

  

 
Neutral (N) = Blue 
Live (L) = Brown 
Earth  = Yellow & Green 
 
 