Installing the Lamp Module 

The OmniCure

®

 S1500 curing system is available configured in two different 

versions.  One version is for standard curing and one version is for surface 
curing. The appropriate type of lamp must be installed depending on which 
configuration your S1500 is set.  

1.  Be sure the AC power cord is disconnected from the unit. 
2.  Remove the screw from the lamp access side panel using the tool 

provided and remove the panel from the unit cover. 

3.  Carefully remove the lamp module from its container, holding only the 

ceramic component and glass rim 

4. 

As illustrated below, position the lamp facing towards the front of the unit 
with the power leads facing towards you.  

 

Caution: 

Do not touch the bulb’s glass envelope or the inside surface of 

the reflector. Skin oils can cause the lamp module to fail prematurely. 

 

5.  Make sure the middle of the lamp is in position to fit into the spring 

clamp. Slide the lamp until it snaps into the spring clamp. The leading 
edge of the reflector should fit snugly into the lamp holder recess. 

 

 

 

 
6.  Locate the 4-pin Intelli-Lamp sensor connector at the rear of the lamp module 

and connect it to its mate located on the top of the lamp-housing wall. 

Tip:

 the Intelli-lamp connector will only attach in the correct orientation. If you  

are having difficulty attaching the connector, try rotating it by 180º. 

 

7.  Locate the Power connector with two leads and connect it to its mate located 

on the bottom of the lamp-housing wall. 

 

Tip:

 the Lamp Power connector will only attach in the correct orientation. If 

you  are having difficulty inserting the connector, try rotating it by 180º. 

 

8.  It is very important to ensure that the lamp anode cooling fin (bar) and 

lamp power lead, at the front of the lamp are centered within the lamp 
holder cutout.  Rotate the lamp as required. 

9.  Replace the lamp housing side panel and tighten the fastening screw. 

Note 1:

 if the lamp housing panel is not secured completely, the lamp will not 

strike and the “

bulb

” message will display when power is turned on to the unit. 

Note 2:

 if the wrong type of lamp has been installed in your unit, the message 

E1

” will appear on the LED display.  

 