EN
11
4. TEChNICAL DATA
Basic parameters:
– analog output galvanicaly isolated:
- current (max. range) -20...20 mA
- voltage (max. range) -10...10 V
- load resistance of the current output
£
500
W
- load resistance of the voltage output
³
500
W
– conversion class
1)
0.2
– averaging time of the measurement
³
0.1 s
– power input < 2 VA
– warm-up time of the separator 10 min
– response time of the separator
³
0.1 s
Rated operating conditions:
– supply depending on the version code 85...253 V a.c./d.c.
20...85 V d.c., 20...65 V a.c.
– frequency of the supply a.c. voltage 45...65 Hz
– ambient temperature - 20...23...55
°
C
– storage temperature - 25...85
°
C
– related air humidity < 95% (inadmissible condensation of water vapour)
– operating position: any
Additional errors:
– from temperature changes 50% of class/10 K
Input parameters:
– resistance of voltage input [V]
> 1 M
W
– resistance of current input [mA]
12
W
±1%
Sustained overload:
- voltage 1.2 X
n
; - current1.1 X
n
Short duration overload:
5 X
n
/3 s
Ensured protection grade acc. to EN 60529:
- casing: IP 40; - from terminal side IP 20
Dimensions
22.5
´
100
´
120 mm
Weight
: 0.125 kg
Fitting
on a 35 mm DIN rail, acc.to EN 60715
Electromagnetic Compatibility:
- noise immunity
EN 61000-6-2
- noise emissions
EN 61000-6-4