NR30PNET-09A
User's manual
53
- warm-up time
15 min.
Real-time clock battery:
CR1220
Additional errors:
in % of intrinsic error
due to ambient temperature changes < 50 % / 10
C
for THD > 8%
< 50 %
Standards met by the meter
Electromagnetic compatibility
immunity in industrial environments EN 61000-6-2
resistance to induced common voltages of radio frequency:
●
level 2 in the frequency range of 0.15 ... 1 MHz,
●
level 3 in the frequency range of 1 MHz ... 80 MHz,
noise emission acc. to EN 61000-6-4
Safety requirements:
according to PN-EN 61010-1 standard
insulation between circuits: basic,
installation category III for voltages up to 300V in relation to earth
installation category II for voltages up to 600V in relation to earth
degree of pollution 2
maximum operating voltage relative to earth
for power circuits and relay outputs 300 V
for measurement input 500 V
for RS485, Ethernet circuits, analog outputs: 50 V
altitude < 2000m