4. Construction and installation

The DLZ clock is made of black painted aluminium sections. The housing offers Protection Classifi-
cation IP0 in general and of IP 0 on the housing side where connections are located. The view and 
dimensions of the clock are shown in Fig. .

Figure 1. View of the clock.

The clock may be wall mounted or underslung. It be mounted at any angle.

5. Electrical connections

Supply and interface connections should be connected according to this instruction. Improper con-
nection could damage the clock, so prior to making connections 

carefully read the information given 

in chapter 3

.

For connecting interface signal, use cable consisting of twisted pairs from the shield. Each pair should 
contain the A and B line of each interface. The connecting terminals and function of the terminals are 
shown in Figure .

Figure 2. Description of the clock’s terminals.

Содержание DLZ

Страница 1: ...DIGITAL CLOCK DLZ Type Service manual...

Страница 2: ......

Страница 3: ...BASIC REQUIREMENTS AND OPERATIONAL SAFETY INSTRUCTIONS 5 4 CONSTRUCTION AND INSTALLATION 6 5 ELECTRICAL CONNECTIONS 6 6 CONFIGURATION 7 7 INTERFACE 7 8 SPECIFICATION 9 9 VERSION CODE 10 10 BEFORE SAND...

Страница 4: ......

Страница 5: ...anual l Guarantee certificate 3 Basic requirements and operational safety instructions The DLZ clocks conform to the PN EN 61010 1 safety standard The following advice must be observed and adhered to...

Страница 6: ...rslung It be mounted at any angle 5 Electrical connections Supply and interface connections should be connected according to this instruction Improper con nection could damage the clock so prior to ma...

Страница 7: ...change the configuration set tings Modifiable basic settings are as follows l The connection of the panel and the computer or master device parameters l The transmission parameters between the panel a...

Страница 8: ...9 Interface 2 bitrate b s 0 2400 1 4800 2 9600 3 14400 4 19200 5 28800 6 38400 7 57600 8 76800 9 115200 2 4006 RW 1 100 Daytime brightness level 100 4007 RW 1 100 Nighttime brightness level 100 4008 R...

Страница 9: ...ess Operation Scope Description 7500 R NA Device 1 The first read register Temperature NA 7501 R NA Device 1 Second read register Humidity NA 7502 R NA Device 1 Third read register NA 7503 R NA Device...

Страница 10: ...20 on the side of the connecting pins The reference conditions and nominal operation conditions operating temperature 0 23 50 C storage temperature 20 75 C humidity 25 95 power supply 85 230 253 V a c...

Страница 11: ...time of the clock again The clock can loose the current time and date due to longer power cut s Other settings are saved The clock displays the time for longer than the date Check the clock configura...

Страница 12: ...NEL METERS DIN INSTRUMENTS ANALOG and DIGITAL CLAMP ON METERS INDUSTRIAL and HOUSEHOLD CONTROLLERS CHART AND PAPERLESS RECORDERS POWER CONTROL UNITS and INVERTERS AUTOMOTIVE DASHBOARD INDICATORS ACCES...

Отзывы: