LIMITED WARRANTY POLICY ON NEW EQUIPMENT - PLEASE READ THE FOLLOWING CAREFULLY
Lumax
®
warrants all lubrication equipment manufactured by Lumax
®
to be free from defects in material and workmanship on
the date of sale by an authorized Lumax
®
distributor to the original purchaser for use. Lumax
®
will during one (1) year, following
the date of purchase, repair, or replace any part of the equipment determined by Lumax
®
to be defective. This warranty applies
only when the equipment is installed, operated, and maintained in accordance with Lumax
®
written recommendations.
Lumax
®
has provided the parts diagram in this manual as a reference tool only. Lumax
®
does not make any representation
or warranty of any kind to the buyer that he or she is qualified to make any repairs to the product or that he or she is qualified
to replace any parts of the product. In fact, Lumax
®
expressly states that all repairs and parts replacements should be undertaken by
certified and licensed technicians and not by the buyer. The buyer assumes all risk and liability arising out of his or her repairs to the
original product or replacement parts thereto, or arising out of his or her installation of replacement parts thereto. If equipment proves to
be defective during this warranty period, it will be repaired or replaced without charge, provided that factory examination indicates the equipment
to be defective. This pump is designed for use with non-corrosive petroleum based products of light to medium viscosity such as, Motor Oils. It should
not be used with Solvents, Acids, Alkalis, Water or other Corrosive Fluids. Warrantee does not cover any Pump showing evidence of Rust or other Corrosion.
This warranty does not cover, and Lumax
®
shall not be liable for general wear and tear, accident, overload, or any malfunction, damage, or wear caused by faulty
installation, misapplication, misuse, abuse, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Lumax
®
component parts. Nor shall Lumax
®
be liable for the equipment repaired or altered by anyone not authorized by Lumax
®
to repair or alter the equipment. Lumax
®
will
also not be liable for malfunction, damage, or wear caused by the incompatibility of Lumax
®
equipment with accessories, equipment or materials not supplied by Lumax
®
.
This warranty is extended to the original retail purchaser only and is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Lumax
®
distributor for verification of the claimed defect. If the claimed defect is verified, Lumax
®
will repair or replace free of charge any defective parts. The equipment will be
returned to the original buyer, transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at
a reasonable charge, which charges may include the cost of parts, labor, and transportation.
This warranty is exclusive, and is in lieu of any other warranties, express or implied, including but not limited to warranty of merchantability or warranty of fitness for
a particular purpose. Lumax
®
sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy
(including but not limited to, incidental or consequential damage for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall
be available. In no event shall Lumax
®
be liable for incidental or consequential damages. The liability of Lumax
®
on any claim for loss or damage arising out of the sale,
resale, or use of lubrication equipment, materials dispensing equipment, and other related equipment should in no event exceed the purchase price. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal
rights, and you may also have other rights, which vary from state to state. Any action for breach of warranty must be brought within two (2) years from the date of sale.
Lumax
®
makes no warranty, and disclaims all implied warranties of merchantability and fitness for a particular purpose in connection with accessories, equipment,
materials, or components sold but not manufactured by Lumax
®
(such as Electric Motors, Switches, Hoses, etc.) are subject reasonable assistance in making any claim
for breach of these warranties. In no event will Lumax
®
be liable for indirect, incidental, special, or consequential damages resulting from Lumax
®
supplying equipment
hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of
Lumax
®
or otherwise.
Any implied warranties applicable to lubrication equipment, materials dispensing equipment, and other related equipment manufactured by Lumax
®
, including the
warranties of merchantability and fitness for a particular purpose, will last only for one (1) year from the date of purchase. Some states do not allow limitations on how
long an implied warranty last, so the above limitation may not apply to you.
© 2003 Lumax
®
. All Rights Reserved.
Lumax
®
and the Products described in it are Copyrighted by Lumax
®
, with All Rights Reserved. This Form may not be Copied in Whole or Part, without the Express Written Consent of Lumax
®
.
DELUXE, ALUMINUM LEVER-ACTION BARREL PUMP
For Use with 15-55 Gallon (57-210 l) Drums
Thank you for purchasing Lumax
®
Pump. Please read this Operational Manual carefully. It is important that you read the entire manual to become
familiar with the unit before you begin assembly and/or operate the unit. Please store this Operational Manual in a safe place for later reference.
Caution :
This pump is designed for use with Non-corrosive Petroleum based products of Light to Medium Viscosity.
It is not meant to be used with Solvents, Acids, Alkalis or other Corrosive Fluids.
Always Pump in a well ventilated area.
Follow the Safety Tips in this Manual. Refer to the materials below, to check which Fluids can be pumped, using this Pump.
WARNING :
Although Gasoline
is oil based, it is
Explosive and Extremely Dangerous
to pump. Ground Wires are essentially required for Gasoline and Flammables.
Materials (Can be Pumped) :
Alcohols, Anti-freeze, Automotive Additives, Cleaning Solutions, Diesel Fuel, Disinfectants, Gasoline, Heating Oil, Kerosene, Machine Oils, Motor Oil, Oil based Fluids,
Oils (Light and Heavy), Transmission Oil, Water and Water based Fluids
Materials (Should Not be Pumped) :
Acids (Weak and Strong), Alkalis, Benzene, Chemicals (Mild and Aggressive), Corrosive Fluids (Mild and Strong), Detergents, Edible Oils, Edible Fluids (Juice,
Wine etc.), Esters, Ethyl, Farm Chemicals, Fertilizers, Grease, Herbicides, Hydrocarbons, Industrial Chemicals, Insecticides, Soaps, Solvents, Thinners and Waxes
Caution
: The above Materials List is for guidance only and is by no means a complete List.
If there is any question about
any Material that can or cannot be pumped,
do not operate the
pump.
Check
with Lumax
®
as to whether it is safe or unsafe, to operate the pump.
WARNING
SAFETY FIRST! - FOR YOUR OWN PROTECTION READ, UNDERSTAND AND OBSERVE THESE SAFETY TIPS AND ALL INSTRUCTIONS BEFORE USING THIS PRODUCT!
Pumps should only be used as recommended. Any tool can fail if it is misused. To avoid Serious Personal Injury when using your Pump, follow these Safety Tips and Rules :
•
Do Not
use Pump for the purpose it is not intended for.
Do Not
Force use Pump. It will do the job Better and Safer at the Rate for which it was Intended. Never Use Handle Extensions to Increase Leverage.
•
Always Wear Appropriate Protective Clothing and Equipment.
Do Not
wear Loose Clothing or Jewelry. They can be caught in Moving Parts. Protective Gloves and Non-skid Footwear are
recommended when working with Pumps. Approved Guards and Protective Equipment, such as, Impact Resistant Safety Glasses, Safety or Chemical Splash Goggles, Full Face Shield, Safety Shoes,
Arm Guards, Protective Gloves and Apron Must be used
for Operator Protection. Wear Protective Hair Covering to contain Long Hair.
•
Use Respirator.
Always
wear proper Face Mask to avoid Inhalation of Fumes and Hazardous Gases. Never Smoke near any fluids that are to be pumped. Always Pump in a well ventilated area.
•
Stay Alert.
Watch what you are doing. Use Common Sense.
Do Not
operate Pump when you are Tired or under the influence of any medications.
Do not Over-reach.
Keep Proper Footing and
Balance at all times.
Be Alert at All Times
especially during Repetitive, Monotonous Operations. You may have demonstrated a certain product hundreds of times, but do not be lulled into Complacency
due to a False Sense of Security. Tools can be extremely unforgiving if not used carefully and as per instructions.
•
Keep Visitors Away.
All Visitors should be kept away from Work Area.
Do Not
let Visitors operate Pump.
•
Check Damaged Parts.
Before use of the Pump, carefully check for any Damaged Parts to determine that the Pump will operate Properly and Perform its intended function. Check for Alignment of
Moving Parts, Binding of Moving Parts, Breakage of Parts, Mounting, and any other Conditions that may affect its Operation. Any Part that is damaged should be properly Repaired or Replaced by an
Authorized Service Center.
•
Maintain Pumps with Care.
Keep Pumps Clean and regularly serviced or maintained for Better and Safe Performance. Follow Instructions for Lubricating and changing Accessories. Inspect Pumps
Periodically and if Pump or any of its parts are Damaged - have it Repaired by an Authorized Service Facility.
Always
keep your Pumps Inspected and
Replace Immediately,
if damaged or Worn.
•
Store Idle Tool. When not in use, Pumps should be Stored in Dry, High and/or in Locked-up place. Childproof the Pump and work area.
•
Pumps
Must
only be repaired by Qualified Technicians.
•
Always
check local area Laws and Ordinances regarding Handling, Pumping and Disposing of Liquids.
Dispose of pumped fluid properly.
Do Not
drain into street drains, house drains, or backyards. Contact your local
Municipal Waste Management officials for proper disposal methods.
If there is any question about a condition
being safe or unsafe, do not operate the pump.
TECHNICAL SPECIFICATIONS :
•
Self Lubricant Seals
•
Self-Priming
•
1-1/4" (32 mm) Inlet Port and 7/8" (22 mm) Outlet Port
•
Delivers 20 oz. (600 ml) per Stroke
•
Equipped with 2" (50 mm) Adjustable Bung Bushing and 40" (1m), Zinc Plated, Suction Tube
for pumping contents from 15 to 55 Gallon (57-210 l) Drums
•
Complete with Covered Drip Tray - returns Spills back in the Container
!
LX-1317
Form / Forma / Forme
LX-1317-IS