background image

Series 6 – TV Advanced Manual

Electrical Installation

  9

2 Introduction

2.1 Technical Data

(Different from IS 6 Advanced, IGA 6 Advanced, IGA 6/23 Advanced, ISR 6 Advanced, or
IGAR 6 Advanced)

Video-Signal:

FBAS-Signal ca. 1 VSS at 75 Ohms,

PAL (B), 50 Hz, CCIR656

video output galvanically isolated from power supply, analog
output and digital interface

Date/Time:

Real time clock with about 14 days buffer (GoldCap)

Connection of Video-Signal:

Separate triaxial socket to support double shielded signal

transmission (at pyrometer)
BNC connector (on user side - BNC-RCA adapter included)

Video signal can be switched off via software

Operating ambient

temperature:

0 to 60 °C on the housing

Note:

During operation the instruments will warm up and might reach an intrinsic

temperature of up to 58 °C.

Optics

Superimposed text elements:  Circular target marker, user text, time, date, measured

temperature
Additional: device temperature or distance or serial no. or
intensity (only ISR)

Field of view:

approx. 11.6% x 8.4% of the adjusted measuring distance

Resolution:

768 x 576 Pixel video chip

768 x 520 Pixel displayed on screen

Brightness control:

Automatic or manual (via software)

Note:

The calibration / adjustment of this pyrometer is carried out in accordance with

VDI/VDE 3511, Part 4.4. See http://info.lumasenseinc.com/calibration for more

information.

Содержание IGA 6-TV Advanced

Страница 1: ...meters IS 6 TV Advanced IGA 6 TV Advanced IGA 6 23 TV Advanced ISR 6 TV Advanced IGAR 6 TV Advanced Addendum to IS 6 Advanced IGA 6 Advanced IGA 6 23 Advanced ISR 6 Advanced and IGAR 6 Advanced Manual...

Страница 2: ...sions 10 3 Electrical Installation 11 3 1 Video Output Electrical Connection 11 3 1 1 Video Image 11 Operating Mode 12 4 Software InfraWin 13 4 1 Set Video Mode Parameters 13 4 2 Adjusting Brightness...

Страница 3: ...included Video signal can be switched off via software Operating ambient temperature 0 to 60 C on the housing Note During operation the instruments will warm up and might reach an intrinsic temperatur...

Страница 4: ...Series 6 TV Advanced Manual Electrical Installation 10 2 2 Dimensions All dimensions in mm...

Страница 5: ...is used for aligning the pyrometer to the measuring object and shows the following information The measuring object and its surroundings Target marking circle The size of the circle corresponds to th...

Страница 6: ...only 2 channel mode 2 dots displayed If the signal falls below the set Relative Signal see Relative Signal in ISR 6 Advanced or IGAR 6 Advanced Manual the temperature displayed on the image will be fl...

Страница 7: ...isplay in addition to measuring temperature o Off no parameter is displayed o Device temperature o Measuring distance o Serial number o Signal intensity ISR 6 TV Advanced and IGAR 6 TV Advanced only B...

Страница 8: ...ss can be set where the automatic control should work With the yellow button the selected range can be moved If the circle representing the current brightness is within the chosen range automatic brig...

Страница 9: ...rawin 15 Comparison between manual and automatic control of brightness The measuring temperature was changed for the image recording from the beginning of the measuring range to 1200 C Manual brightne...

Страница 10: ...be size adjusted and positioned at any place of the screen The properties of the pyro s video chip as well as properties of the video grabber can be adjusted with InfraWin 5 5 1 1 Adjusting Grabber S...

Страница 11: ...rently only PAL_B is supported 5 1 3 Viewing the Video Image During a temperature measurement of the pyrometer the video image can be displayed on the screen by pressing the TV button The video image...

Страница 12: ...th the 2 digit device address AA e g 00 This is followed by 1 lower case command letter and 2 numbers finished with CR Example Read Command Entry 00v08 CR Selectable parameter that is additionally sho...

Страница 13: ...of 2 v01 Coordinates of temperature display read limits Answer 000300000208 PAL Format xxxXXXyyyYYY xxx min X Value XXX max X Value yyy min Y Value YYY max Y Value v02 description see v01 but Coordina...

Страница 14: ...n see v10 however Text properties Overlay_3 v14 v14 store v10 v11 v12 v13 text properties in flash memory v18 v18 Brightness control settings read Answer 1 digit hex v18X Brightness control settings w...

Страница 15: ...ontrol limits v24 Control limit read limits Answer 00FF00FF v25 v25 Control limit store selection in flash memory v26 v26 Time read Answer 6 digit decimal v26hhmmss Time write hh hour 00 23 mm minute...

Страница 16: ...separately 7 2 Reference numbers accessories video related 3 920 600 3 920 610 3 920 620 3 920 630 3 920 640 3 920 650 3 920 660 3 920 670 3 920 680 3 920 690 Video cable BNC 5 m long Video cable BNC...

Отзывы: