Technical data 

 

Temperature range: 

IS 210  

MB 18:  650 to 1800°C  (1202 to 3272°F) 

IS 210  

MB 25:  800 to 2500°C  (1472 to 4532°F) 

IGA 210 

MB 13L:  300 to 1300°C 

(572 to 2372°F) 

IGA 210 

MB 18L:  350 to 1800°C 

(662 to 3272°F) 

Sub range: 

User adjustable within the temperature range  
(via service interface). Minimum span 51°C 

Data handling: 

Digital 

 

Spectral range: 

IS 210:  0.8 to 1.1 µm 
IGA 210:  1.45 to 1.8 µm 

IR detector: 

Si (IS 210);  InGaAs (IGA 210) 

 

Power supply: 

24 V DC ± 25%, ripple < 0.5 V 
LED: 5 to 30 V DC, 35 mA 

Power consumption: 

max. 0.6 W (without LED targeting light) 

Analog output: 

Linear current 4 to 20 mA 

Note:

  At ambient temperatures > 75°C the output signal is set 

to approx. 3.9 mA 

Load: 

max. 700 



 at 24 V power supply; 400 

 (18 V); 1000 

 (30 V)

 

Service interface: 

for parameter programming with portable setup device HT 6000 
or via USB adapter and 

InfraWin

 software (accessory) 

 

Emissivity 

ε

5 ... 100% adjustable via service interface 

Response time t

90

20 ms; up to 10 s adjustable via service interface 

Maximum value storage: 

Clear time: Off, 50 ms, 250 ms, 1 s, 5 s, 25 s, auto  

 

Uncertainty: 

0.5% of measured value in °C + 1°C  (

ε

 = 1, t

90 

= 1 s, T

amb.

 = 23°C) 

Repeatability: 

0.1% of measured value in °C + 1°C  (

ε

 = 1, t

90 

= 1 s, T

amb.

 = 23°C) 

 

Ambient temperature: 

0 to 70°C 

Storage temperature: 

-20 to 70 °C 

Weight: 

approx. 450 g 

Housing: 

Stainless steel 

Operating position: 

Any 

Protection class: 

IP65 (IEC 60529) 

CE approval / EMV tests:  Corresponds to EU regulations about  

electromagnetic immunity (industry norm) 

 
 

1.1 

Dimensions 

 

 

Содержание IGA 210

Страница 1: ...IS 210 IGA 210 IMPAC Pyrometer Proven Quality Operation Manual Betriebsanleitung...

Страница 2: ...a USB adapter onto a PC 6 3 4 Connection to the portable parametrizing device HT 6000 7 4 Mechanical Installation accessories 7 5 Optics 7 6 Alignment with the LED targeting light 8 7 Parameter Settin...

Страница 3: ...s that arise from the use of any exam ples or processes mentioned in this manual or in case the content of this document should be incomplete or incorrect LumaSense Technologies reserves the right to...

Страница 4: ...peratures 75 C the output signal is set to approx 3 9 mA Load max 700 at 24 V power supply 400 18 V 1000 30 V Service interface for parameter programming with portable setup device HT 6000 or via USB...

Страница 5: ...dditional devices operating with this mains voltage e g transformers Touching mains voltage can be fatal An incorrect connection and mounting can cause serious health or material damages Only qualifie...

Страница 6: ...corder Digital display 230 V 4 20 mA white brown Schirm schwarz 24 V DC Power supply green yellow Power supply for LED targeting light White 24 V Pin 1 Brown 0 V Pin 2 Black Shield Green LED Pin 5 Yel...

Страница 7: ...least as big as the spot size of the pyrometer in the meas uring distance The following drawings show the pyrometer s spot sizes M in different measuring distances a The spot size M in a distance of a...

Страница 8: ...ch are different from the nominal distance of the selected optics may be calculated using the following formula D D M a a M 2 2 D D M a a M 1 1 6 Alignment with the LED targeting light For exact measu...

Страница 9: ...r the two spectral ranges of the in struments are listed in the emissivity table below The tolerance of the emissivity values for each material is mainly dependent on the surface conditions Rough surf...

Страница 10: ...until a new hot object appears in the measuring beam The temperature which has to be recognized as hot is defined by the low limit of the adjusted sub range The stored maximum value will be deleted wh...

Страница 11: ...surement curves Subsequent analysis graphically or in table form for print out or export Spot size calculator to calculate spot sizes in any distances 9 Transport packaging storage With faulty shippin...

Страница 12: ...suring distance see 5 Emissivity set too high Set lower correct emissivity corresponding to the material see 7 2 Lens contaminated Clean lens carefully see 10 2 Temperature indication too high Emissiv...

Страница 13: ...60 Connection cable 5 m 3 821 770 Connection cable 10 m 3 821 780 Connection cable 15 m 3 821 790 Connection cable 20 m 3 821 800 Connection cable 25 m 3 821 810 Connection cable 30 m 3 826 500 Portab...