Attaching Fixed Bracket

Attaching Cable Holder

Step 1

Screw fixed bracketry to mounting board on underside of luminaire and screw bracket in place.  Repeat until all four 

screws are firmly in place.

Torque:

 1.5 N.m. 

Step 1

Clip the cable under the cable holder. Pinch firmly to remove and re-attach cable holders. Repeat these steps for each 

cable holder on each luminaire. NOTE: This is not applicable for 1 ft luminaires.

Содержание Vestalux V2 LS9016

Страница 1: ...omplies with local electrical rules and regulations Input voltage range 30 48 Vdc Only use Lumascape power supply control equipment and leader cables Ensure mains input power is surge protected Never make connections while the power is connected Do not make modifications or alter the product Keep lminaire clean and free of debris Only clean with warm water Do not use chemicals or abrasives to clea...

Страница 2: ...uctions The Leader Cable A connects to the first Luminaire Input B via an IP68 quick connector The LS9016 is designed for loop in loop out The output C of the previous luminaire will connect to the input B of the next luminaire At the end of the run the luminaire chain has to be terminated with a Terminator H Luminaires come with Mounting Brackets Fixed E or Adjustable D and Cable Holders G Lumina...

Страница 3: ...rcos CA 92078 USA P 1 650 595 5862 F 1 650 595 5820 E info lumascape com lumascape com 3 8 IN0184 200717 Products and specifications are subject to change without notice Product Overview End View Mounting Bracket Side View Fixed Vertical Mounting Adjustable Horizontal Mounting Mounting Orientations 3 2 81 mm 3 2 81 mm 1 5 39 mm 1 5 39 mm 2 2 57 mm 3 5 89 mm 1 8 45 mm 12 7 323 mm 24 5 622 mm 36 2 9...

Страница 4: ...pe com lumascape com 4 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Adjustable Bracket Step 1 Step 2 Screw adjustable bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place NOTE The adjustable mounting bracket is reversible OR Torque 1 5 N m Use allen key to loosen bracket s til...

Страница 5: ...om lumascape com 5 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Fixed Bracket Attaching Cable Holder Step 1 Screw fixed bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place Torque 1 5 N m Step 1 Clip the cable under the cable holder Pinch firmly to remove and re attach cable h...

Страница 6: ... in the chain When placing the luminaires in an end to end setup be sure to leave a minimum gap of 0 4 10 mm to allow for thermal expansion Minimum thermal expansion gap between luminaires 0 4 10 mm Step 1 It is recommended to mount the luminaire with 316 stainless steel screws To start put a single screw into one bracket Use a spirit level or digital inclinometer to make sure the luminaire is lev...

Страница 7: ...p 1 Once the physical components have been installed it is time to complete the electrical installation Step 2 Power up the circuit to test the installation Luminaire to Luminaire Connect the output of the previous luminaire to the input of the next luminaire in the chain and tighten the connectors Do this for all the luminaires within the chain Leader Cable Connect the leader cable to the input o...

Страница 8: ...48 V Power Supply 120 W 240 W 320 W 480 W 600 W 4 W ft 50 ft 15 m 20 44 56 80 96 98 ft 30 m 20 44 56 76 88 164 ft 50 m 20 40 52 64 72 6 W ft 50 ft 15 m 14 28 36 56 64 98 ft 30 m 14 28 36 48 56 164 ft 50 m 14 26 34 44 48 Values in the above table show the maximum circuit loading per 48V circuit Values are based on end to end spacing ETE Extended fixture cables inclusion of jumper cables or longer l...