background image

INSTALLATION INSTRUCTIONS

FACADE OUTLINER

Vestalux

 

V2

 

LS9016

ASIA PACIFIC

  18 Brandl Street, Eight Mile Plains, QLD 4113, Australia    

P:

 +61 7 3854 5000 | 

F:

 +61 7 3854 5001 | 

E:

 [email protected]

lumascape.com.au

NORTH AMERICA

  1940 Diamond Street, San Marcos, CA 92078, USA 

P:

 +1 650 595 5862 | 

F:

 +1 650 595 5820 | 

E:

 [email protected]

lumascape.com

1 /8

IN0184-200717

Products and specifications are subject to change without notice.

Product Warranty is void if product is not installed as per installation 

instructions and in compliance with all local and provincial codes.

Follow all safety instructions carefully. Failure to do so will

 

void warranty. 

Ensure installation complies with local electrical rules

 

and 

regulations.

Input voltage range 30-48 Vdc.

Only use Lumascape power supply, control equipment and

 

leader cables.

Ensure mains input power is surge protected.

Never make connections while the power is connected.

Do not make modifications or alter the product.

Keep lminaire clean and free of debris.

Only clean with warm water.

Do not use chemicals or abrasives to clean luminaire as this may

 

void the product warranty.

Connectors are to be kept clean and dry at all times.

Once installed, all connectors are to be mated and a terminating

 

plug is required on the last fitting of run.

READ ALL SAFETY INSTRUCTIONS FIRST

NO POWER

TOOLS

KEEP AWAY FROM 

FLAMMABLE MATERIAL

DO NOT USE SILICONE 

ON OUTSIDE SURFACE

KEEP ELECTRONICS FREE 

FROM DIRECT AND MOISTURE

DO NOT HOSE OR 

PRESSURE CLEAN

DO NOT USE CHEMICALS 

OR ABRASIVES

A

A+

A++

Содержание Vestalux V2 LS9016

Страница 1: ...omplies with local electrical rules and regulations Input voltage range 30 48 Vdc Only use Lumascape power supply control equipment and leader cables Ensure mains input power is surge protected Never make connections while the power is connected Do not make modifications or alter the product Keep lminaire clean and free of debris Only clean with warm water Do not use chemicals or abrasives to clea...

Страница 2: ...uctions The Leader Cable A connects to the first Luminaire Input B via an IP68 quick connector The LS9016 is designed for loop in loop out The output C of the previous luminaire will connect to the input B of the next luminaire At the end of the run the luminaire chain has to be terminated with a Terminator H Luminaires come with Mounting Brackets Fixed E or Adjustable D and Cable Holders G Lumina...

Страница 3: ...rcos CA 92078 USA P 1 650 595 5862 F 1 650 595 5820 E info lumascape com lumascape com 3 8 IN0184 200717 Products and specifications are subject to change without notice Product Overview End View Mounting Bracket Side View Fixed Vertical Mounting Adjustable Horizontal Mounting Mounting Orientations 3 2 81 mm 3 2 81 mm 1 5 39 mm 1 5 39 mm 2 2 57 mm 3 5 89 mm 1 8 45 mm 12 7 323 mm 24 5 622 mm 36 2 9...

Страница 4: ...pe com lumascape com 4 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Adjustable Bracket Step 1 Step 2 Screw adjustable bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place NOTE The adjustable mounting bracket is reversible OR Torque 1 5 N m Use allen key to loosen bracket s til...

Страница 5: ...om lumascape com 5 8 IN0184 200717 Products and specifications are subject to change without notice Attaching Fixed Bracket Attaching Cable Holder Step 1 Screw fixed bracketry to mounting board on underside of luminaire and screw bracket in place Repeat until all four screws are firmly in place Torque 1 5 N m Step 1 Clip the cable under the cable holder Pinch firmly to remove and re attach cable h...

Страница 6: ... in the chain When placing the luminaires in an end to end setup be sure to leave a minimum gap of 0 4 10 mm to allow for thermal expansion Minimum thermal expansion gap between luminaires 0 4 10 mm Step 1 It is recommended to mount the luminaire with 316 stainless steel screws To start put a single screw into one bracket Use a spirit level or digital inclinometer to make sure the luminaire is lev...

Страница 7: ...p 1 Once the physical components have been installed it is time to complete the electrical installation Step 2 Power up the circuit to test the installation Luminaire to Luminaire Connect the output of the previous luminaire to the input of the next luminaire in the chain and tighten the connectors Do this for all the luminaires within the chain Leader Cable Connect the leader cable to the input o...

Страница 8: ...48 V Power Supply 120 W 240 W 320 W 480 W 600 W 4 W ft 50 ft 15 m 20 44 56 80 96 98 ft 30 m 20 44 56 76 88 164 ft 50 m 20 40 52 64 72 6 W ft 50 ft 15 m 14 28 36 56 64 98 ft 30 m 14 28 36 48 56 164 ft 50 m 14 26 34 44 48 Values in the above table show the maximum circuit loading per 48V circuit Values are based on end to end spacing ETE Extended fixture cables inclusion of jumper cables or longer l...

Отзывы: