ez-Line
VM16 : Manual
4.5 Response/ Notification List
Response/
Notification
NOD
Description
ok
0 Communication success
error_too_short
0 Communication failure: checksum digit is short
error_bad_checksum
0
Communication failure: checksum parameter is not right,
checksum digit is too long.
error_checksum
0 Communication failure: checksum value is not right
error_invalid_param
0 Communication failure: invalid parameter
error_invalid_comman
d
0
Communication failure: invalid command
state_model
1
Model name output
Data1: Model name (VM16, VS6, VM6, VM4,…)
state_ver
3
Version information
Data1: Major Version
Data2: Minor Version
Data3: Revision
state_cfg_all
16
Information status of 16 outport associated 16 inport
Data1 ~ Data16 : See
Input Channel List
state_cfg_one
2
Information status of specified 1 outport
Data1: See
Output Channel List
Data2: See
Input Channel List
state_inloss_all
16
Information status of Signal Loss [off/on] for 16 inport
Data1 ~ Data16: See
Loss List
state_inloss_one
2
Information status of signal Loss [off/on] for specified inport
Data1:
Input Channel loss List
Data2: See
Loss List
state_ipaddr
4
IP address status
Data1~ Data4 : IP address
state_subnetmask
4
Subnet mask status
Data1~ Data4 : Subnet mask address
state_gateway
4
Gateway status
Data1~ Data4 : Gateway address
state_port
1
Port number status
Data1: Port number
state_macaddr
6
Mac address status
Data1~ Data6 : Mac address
state_refinled
1
REF IN LED status
Data1: 0/1 = led off/led on
state_preset0
16
Information status for 16 outport associated with 16 inport
(preset)
Data1 ~ Data16 : See
Input Channel List
state_preset1
16
Information status for 16 outport associated with 16 inport
(preset)
Data1 ~ Data16 : See
Input Channel List
state_preset2
16
Information status for 16 outport associated with 16 inport
(preset)
Data1 ~ Data16 : See
Input Channel List
state_preset3
16
Information status for 16 outport associated with 16 inport
(preset)
Data1 ~ Data16 : See
Input Channel List
state_rcpll
1
RCP Lock Led status [0/1=off/on], 0 respresent RCP controling
Data1: 0/1 = led off/led on
19