Lock the Configuration
The configuration can be locked to prevent unintended changes. When locked, the input
selection functions normally, but setup parameters are fixed. The command format is:
MENU
→
MISC
→
LOCK
→
(
UNLOCKED
,
LOCKED
)
OK
The following command can be used to unlock the configuration memories if the on-
screen menu cannot be displayed.
MENU
0
9
1
5
Same as
MENU
→
MISC
→
LOCK
→
UNLOCKED
OK
Test Patterns
Warning:
Test patterns can cause screen burn-in if left on-screen for more then a few seconds.
Activate test pattern. The
…
and
†
arrows select the test pattern. The intensity is adjusted
from 10 to 100 IRE, in 10 IRE steps, using the
‡
and
ˆ
arrows. The command format is:
MENU
→
MISC
→
TPAT
→
OK
[
…
,
†
,
ˆ
,
‡
]
Menu Timeout
The
MENU
timeout can be changed with the following command:
MENU
0
9
0
5
Toggle menu timeout. Short (default) or long
Front Panel LED Function
By default the front panel LED is illuminated for a short time after a command and then
turned off. This behavior can be changed so the LED stays on while the unit is on. The
command is:
MENU
0
9
2
5
Toggle LED as "activity" (default) or "power."
Zoom Step
A smaller zoom step of about 5% can be selected instead of the normal step of about
15%. The command format is:
MENU
0
9
2
3
Toggle zoom-step between default and 5%.
Sidebar Pan
To help reduce screen burn-in with 4:3 sources on widescreen displays, the output can be
slowly moved left and right a fractional pixel step every few minutes. The command is:
MENU
0
9
8
7
Toggle Sidebar-pan for anti-burn. Default = off.