 5

LR510

Horizontal use of LR510

• Set up the LR510 on a surface that is as level as possible or fasten it to a  tripod.
• Turn the pendulum lock in the arrow’s “Unlock”       direction to its limit. This releases the 

locking mechanism that protects the pendulum during transport.

• Press the On/Off button.
• Within its range of +/- 3,5°, the LR510 will level itself automatically and the prism head will 

begin to turn.

• The speed of rotation can be changed using the up & down buttons from 100 - 300 RPM.

Vertical use of LR510

• Turn the pendulum lock in the arrow’s “Lock”      direction to its limit.
• Insert the vertical operatin foot into the vertical foot recepticle and adjust the foot untill the 

vertical operation vial is centered between the centre markings.

• Press the On/Off button. The prism head will begin to rotate.

Note:

 Always unlock the pendulum lock when the LR510 is being used for horizontal 

levelling by turning the transport lock to its “Unlock”        position. If the unit is currently 

outside of its automatic levelling range (> 3,5°) , a warning signal will sound and the 
prism head will not rotate. The unit must then be placed on a surface which is closer to 
level. When in  vertical use, the unit does 

not

 level itself automatically.

Battery

cover

Содержание Lufkin LR510

Страница 1: ...LR510 Self Levelling Rotary Laser Level USER GUIDE...

Страница 2: ...alist workshop Calibration by yourself is only approximate and the accuracy of the calibration will depend on the care with which you proceed Warranty The warranty period is two years from the date of...

Страница 3: ...rtical operation make sure that the pendulum lock is set to lock failure to do so may result in damage to the device Plumb beam aperture Rotating laser window Carry handle Control panel Bubble adjusti...

Страница 4: ...4 LR510 Vertical foot recepticle used in vertical operation Pendulum Lock Battery cover Charger power supply socket...

Страница 5: ...rn the pendulum lock in the arrow s Lock direction to its limit Insert the vertical operatin foot into the vertical foot recepticle and adjust the foot untill the vertical operation vial is centered b...

Страница 6: ...range shifts counter clock wise Laser Speed Scan Direction Button In continuous rotation mode Increase speed In scan mode Scan range shifts clock wise Scan mode button SCAN MODE INDICATOR CONTINUOUS...

Страница 7: ...On off switch Off switch Scan mode Backlight LCD Hand receiver mode Volume Detector bracket Laser Speed Scan Direction Button In continuous rotation mode Reduce speed In scan mode Scan range shifts co...

Страница 8: ...an be changed using the up down buttons Adjust the unit to the desired angle Slope angle can be set precisely and quickly with the aid of the optional tilt plate Part No LTP1 Important Horizontal leve...

Страница 9: ...ill become void If the LED blinks constantly either the batteries must be exchanged or recharged Insertion of batteries in the detector Remove the battery cover 9 and insert the batteries as shown by...

Страница 10: ...IIA EN60825 1 2007 10 Laser output rating 5 mW Rechargeable Batt batt operating time approx 20 h 45 h 4 x type AA Battery recharging time approx 14 h Working temperature range 10 C 40 C Protection cla...

Страница 11: ...ne of the sides is towards the wall or post 4 Mark the level point on the wall or post and label this point C 5 Rotate the Laser on the surface or Tripod 180 so that the other side is towards the wall...

Страница 12: ...You are entitled to a replacement or refund for a major failure and for compensation for any other reasonably foreseeable loss or damage You are also entitled to have the goods repaired or replaced i...

Отзывы: