background image

UMB Analogue/Digital Converter ANACON 

Operating Manual 

14 

 

G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany

 

 

Wind 

 

 

 

 

Vect. avg 

 

 

 

 

 

400 

420 

440 

460 

480 

Wind Speed 

100.0 

m/s 

405 

425 

445 

465 

485 

Wind Speed 

360.0 

km/h 

410 

430 

450 

470 

490 

Wind Speed 

223.7 

mph 

415 

435 

455 

475 

495 

Wind Speed 

194,4 

kts 

501 

521 

541 

561 

581 

Wind Direction 

359.9 

° 

Precipitation 

600 

 

 

 

 

precipitation absol. 

 

 

mm 

601 

 

 

 

 

precipitation absol. 

 

 

mm 

620 

 

 

 

 

precipitation diff. 

 

 

mm 

621 

 

 

 

 

precipitation diff. 

 

 

mm 

640 

 

 

 

 

precip. intens. 

 

 

mm/h 

641 

 

 

 

 

precip. intens. 

 

 

mm/h 

Digital input 

700 

720 

740 

760 

 

Digital Input 

 

701 

721 

741 

761 

 

Digital Input 

 

Voltage 

10000 

10020 

10040 

10060 

 

Voltage 

1000 

mV 

10001 

10021 

10041 

10061 

 

Voltage 

1000 

mV 

Current 

10100 

10120 

10140 

10160 

 

Current 

24 

mA 

10101 

10121 

10141 

10161 

 

Current 

24 

mA 

Содержание 8160.UANA

Страница 1: ...ting Manual UMB Analogue Digital Converter ANACON G Lufft Mess und Regeltechnik GmbH Fellbach Germany 1 Operating Manual UMB Analogue Digital Converter ANACON Order Number 8160 UANA Status V6 1425 03...

Страница 2: ...UFACTURER 20 EC CERTIFICATE OF CONFORMITY 21 Version history Version Date Compiled by Comments V1 15 09 2006 EES SH First edition V2 11 01 2007 EES Sensor connection scheme for wind sensor changed add...

Страница 3: ...witched off Protect the device from direct sunlight The equipment requires an adjustment period of several minutes on being moved to a location with different climate conditions Pay attention to the t...

Страница 4: ...nverter ANACON Operating Manual 4 G Lufft Mess und Regeltechnik GmbH Fellbach Germany Symbols used Important indication concerning possible hazards to the user Important indication for the correct fun...

Страница 5: ...tion of the ANACON via RS232 port and an additional ISOCON 8160 UISO Features 2 analogue inputs with 24 bit resolution and signal conditioning for resistance PT100 PT1000 voltage current frequency and...

Страница 6: ...ital Converter ANACON Operating Manual 6 G Lufft Mess und Regeltechnik GmbH Fellbach Germany ANACON UMB Analogue Digital Converter Summary Status LED s Input Channel B Input Channel A Power supply RS4...

Страница 7: ...ACON G Lufft Mess und Regeltechnik GmbH Fellbach Germany 7 Analogue Inputs Channel A and Channel B ANACON UMB Connection Channel B Channel A PIN Name 1 Power Sensor Power Supply 2 ANA_ Sense High Inpu...

Страница 8: ...al 8 G Lufft Mess und Regeltechnik GmbH Fellbach Germany Mounting Rail Bus Connector NOTE The assembly must take place on a grounded DIN rail Earth 24V Power Supply Feed Earth 24V Power Supply Feed 24...

Страница 9: ...ration and functioning of the ANACON Their meanings are as follows Red LED If this LED lights up permanently after switch on there is a configuration fault If this LED lights up during operation an un...

Страница 10: ...se ensure that the polarity and pin assignment are correct on connection Incorrect connection can cause the destruction of the ANACON module 2 Next mount the ANACON module which you wish to configure...

Страница 11: ...B of the ANACON module Please note that a fixed assignment is specified for channels A and B for the combined sensors for temperature and relative humidity as well as the wind speed and wind direction...

Страница 12: ...4 Resistance 3 wire PT100 PT1000 Voltage V V V V Current self powered I I I I Current ANACON powered I I I I Frequency F F F F Impulse Digital Input D D D D Lufft Sensors 8160 TF T red red white red r...

Страница 13: ...50 0 C 105 125 145 165 A temperature 328 0 842 0 F 101 121 141 161 B temperature 200 0 450 0 C 106 126 146 166 B temperature 328 0 842 0 F 110 130 150 170 dewpoint 200 0 450 0 C 111 131 151 171 dewpoi...

Страница 14: ...kts 501 521 541 561 581 B Wind Direction 0 359 9 Precipitation 600 A precipitation absol mm 601 B precipitation absol mm 620 A precipitation diff mm 621 B precipitation diff mm 640 A precip intens mm...

Страница 15: ...40 10260 A Resistance 0 2000 Ohm 10201 10221 10241 10261 B Resistance 0 2000 Ohm Frequency 10300 10320 10340 10360 A Frequency 10 10000 Hz 10301 10321 10341 10361 B Frequency 10 10000 Hz Pulses 10500...

Страница 16: ...ction Phoenix bus connector gold 5 pole Function display Green LED flashes every 10 seconds RS485 interface internal bus Standard RS485 2 wire half duplex Transmission type Protocol transparent 8 data...

Страница 17: ...mperature with PT100 200 500 C 0 02 C for 50 C t 150 C otherwise 0 1 C 0 1 C for 50 C t 150 C otherwise 0 5 C Temperature with PT1000 200 500 C 0 02 C for 50 C t 150 C otherwise 0 1 C 0 1 C for 50 C t...

Страница 18: ...ure Humidity Sensor 8160 TFF Temperature PT1000 30 70 C Resistance 882 2 1270 8 Ohms Humidity 0 100 RH Frequency Barometric Air Pressure Sensor 8355 03 Air Pressure 0 1200 hPa Current 4 20 mA Wind Spe...

Страница 19: ...ent temp 40 70 C Permissible rel humidity 0 95 RH non condensing Operating conditions Permissible operating temp 30 60 C Permissible rel humidity 0 95 RH non condensing Housing Material PA V0 green Wi...

Страница 20: ...with European Directives 2002 96 EC and 2003 108 EC waste electrical and electronic equipment Waste equipment must not be disposed of as household waste For environmentally sound recycling and the di...

Страница 21: ...d the Low Voltage Directive in accordance with 73 23 EC The above mentioned equipment specifically conforms to the following EMC Standards EN 61000 6 2 2005 Part 6 2 Generic Standards Immunity for ind...

Отзывы: