TEMP!
The system is running too hot and has shut down the RF
output as a safety precaution. Check the fans for correct
operation. Also check the antenna system, including all cabling
(and/or filters and/or combiners where fitted) for correct
operation. The FWD! indicator (see below) will also show and the
standby transmission system (where used) will have activated
(TTL control).
REF!
! The system has detected a fault in the antenna system
and has shut down the RF output as a safety precaution. Check
the antenna system, including all cabling (and/or filters and/or
combiners where fitted) for correct operation. The FWD!
indicator (see below) will also show and the standby
transmission system (where used) will have activated (TTL
control).
FWD!
The system has detected there is no forward power. This
may be due to one or both of the above symptoms, due to a PLL
failure, or due to excessive power setting. The standby
transmission system (where used) will have activated (TTL
control).
The RDS content can be periodically updated using a Windows™
computer and USB programming device (purchased separately)
connected to the RDS Programming Port connector on the rear panel.
Follow the instructions provided with the RDS Programming Device
and software.
Ensure air vents and internal air tunnels are kept free from dust during
operation.
The cooling fans should be replaced after 40,000 hours of cumulative
operation. This life rating is for guidance only and is subject to ideal
environmental operating conditions. Immediately replace any fan that
fails or becomes slow or noisy, immediately. Replacement fan
assemblies with wiring loom and mating connector are available from
the manufacturer. It is recommended that replacement work must be
carried out by the manufacturer or an approved agent.