background image

Ethernet Industrial Router

XR5i v2

USER’S MANUAL

23-05-16

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

  

LUCOM GmbH * Ansbacher Str. 2a * 90513 Zirndorf * Tel. 09127/59 460-10 * Fax. 09127/59 460-20 * www.lucom.de 

 

  

w

w

w

.luco

m.d

e   

  

  

inf

o@lucom

.de

 

Содержание XR5i

Страница 1: ...Ethernet Industrial Router XR5i v2 USER S MANUAL 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 2: ...ips or information of special interest GPL licence Source codes under GPL licence are available free of charge by sending an email to info conel cz Conel s r o Sokolska 71 562 04 Usti nad Orlici Czech Republic Manual Rev 1 released in CZ February 2 2016 i 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 3: ... 5 7 1 Status indication 14 5 7 2 Power connector PWR 15 5 7 3 Ethernet Port ETH 16 5 7 4 PORT1 17 5 7 5 PORT2 17 5 7 6 USB Port 18 5 7 7 I O Port 18 5 7 8 Reset 20 6 First Use 21 6 1 Connecting the router before first use 21 6 2 Start 22 6 3 Configuration 22 6 3 1 Configuration over web browser 22 6 3 2 Configuration over Telnet 23 7 Technical Parameters 24 7 1 Basic parameters 24 7 2 Standards a...

Страница 4: ...hnical parameters of expansion port 25 8 Recommended Literature 26 9 Troubleshooting 27 9 1 FAQ 27 10 Customers Support 29 iii 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 5: ...of DIN holder 12 15 Removing from the DIN rail 12 16 Front panel XR5i v2F 13 17 Power connector 15 18 Connection of power supply 15 19 Ethernet connector 16 20 Connection of ethernet cable 16 21 PORT1 cable connection 17 22 PORT2 cable connection 18 23 USB connector 18 24 I O connector 19 25 Connection of I O cable 19 26 Connection of input and output to the router 19 27 Router reset 20 28 Router ...

Страница 6: ...of Ethernet connector 16 8 Connection of USB connector 18 9 Connection of I O port 18 10 Description of reset and restart router 20 11 Basic parameters 24 12 Standards and regulations 24 13 Technical parameters of processor 25 14 Technical parameters of I O port 25 1 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 7: ... exceeded by the maximum voltage 36 V DC power connector on the router Do not expose the router to extreme ambient conditions Protect the router against dust moisture and high temperature The router should not be used at petrol stations of flammable and explosive materials We remind the users of the duty to observe the restrictions concerning the utilization of radio devices at petrol stations in ...

Страница 8: ...overy techniques to minimize the impact on the environment This product contains high quality materials and components which can be recycled At the end of it s life this product MUST NOT be mixed with other commercial waste for disposal Check the terms and condi tions of your supplier for disposal information 3 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 46...

Страница 9: ...o ensure safe communication Web interface provides detail statistics about the router activities Other diagnostic functions ensuring continuous communication include automatic function ality inspection or hardware Watchdog which monitors the status of the router With the help of a special window start up script window you may insert Linux scripts for various actions For some applications the key o...

Страница 10: ... Temperature range for power supply is reduced to 0 C to 40 C As optional accessories can also be supplied the following expansion ports two boards for Full version RS232 RS485 422 MBUS ETHERNET CNT SWITCH WIFI WMBUS or SDH Separation columns for mounting expansion boards are included 5 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www luc...

Страница 11: ...sions Router Box I O USB PORT1 PORT2 ETH XR5i v2F Plastic 1 x 1 x 1 x 1 x 1 x XR5i v2F SL Metal 1 x 1 x 1 x 1 x 1 x Table 1 Router versions Figure 2 Front panel XR5i v2F Figure 3 Front panel XR5i v2F with WiFi Figure 4 Front panel XR5i v2F SL Figure 5 Front panel XR5i v2F SL with WiFi 6 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www luc...

Страница 12: ... version in the plastic box XR5i v2F SL XR 5i v2 Full version in the metal box Table 2 Delivery identification Figure 6 Label XR5i v2F Figure 7 Label XR5i v2F SL 7 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 13: ...set Version with SWITCH expansion port PORT1 PORT2 XR5i v2F SWITCH set Version with WIFI expansion port PORT2 XR5i v2F WIFI set Version with WMBUS expansion port PORT2 XR5i v2F WMBUS set Version with SDH expansion port PORT2 XR5i v2F SDH set Table 3 Ordering codes Code for the second expansion port must be written after the first port See example below Full version with RS485 port in plastic box X...

Страница 14: ... box 5 4 1 Plastic box Figure 8 Basic dimensions of plastic box 5 4 2 Metal box Figure 9 Basic dimensions of metal box 9 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 15: ...th EMC according to EN 60439 1 ed 2 00 A1 04 Compliance of EN 60439 1 ed 2 00 A1 04 specification it is necessary to observe next assembly of the router to the switch board For every cables we recommend to bind the bunch we recommend for this use Length of the bunch combination of power supply and data cables can be maxi mum 1 5 m If the length of data cables exceeds 1 5 m or in the event of the c...

Страница 16: ...Figure 13 Space in front of connectors metal For correct function of the router we recommend to use in the switch board earth bonding distribution frame for grounding of power supply of router data cables and antenna 11 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 17: ...re 14 Default position of DIN holder For removing from the DIN rail it is necessary to lightly push upward the router so that the top part of the CPD2 holder or CKD2 for metal version hitched to the DIN rail get out of this rail and then fold out the top part of the router away from the DIN rail Figure 15 Removing from the DIN rail 12 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 5...

Страница 18: ... CNT or SWITCH PORT2 RJ45 Connector for expansion port RS232 RS485 422 MBUS SWITCH WIFI WMBUS or SDH USB USB A Host Connector for connection of USB devices to the router Sup ports devices with PL 2303 and FTDI USB RS232 converters I O 3 pin Connector for connection of the binary input and output Table 4 Front panel description Figure 16 Front panel XR5i v2F 13 23 05 16 LUCOM GmbH Ansbacher Str 2a ...

Страница 19: ...can be selected by user OUT Green On Binary output active IN Green On Binary input active ETH Green On Off Selected 100 Mbit s Selected 10 Mbit s ETH Yellow On Blinking Off The network cable is connected Data transmission The network cable is not connected PORT Green Depends on the expansion port see user s manual for used port PORT Yellow Depends on the expansion port see user s manual for used p...

Страница 20: ...e router The power consumption during receiving is 1 6 W The power consumption when using WiFi is 1 9 W The peak power consupmtion during data sending is 2 5 W However values of consumption can be increased if some expansion port is eqquipped For correct operation it is necessary that the power source is able to supply a peak current of 0 5 A Circuit example Figure 18 Connection of power supply Th...

Страница 21: ...Output 4 5 6 RXD Receive Data negative pole Input Output 7 8 Table 7 Connection of Ethernet connector Figure 19 Ethernet connector ATTENTION ETH port is not POE Power Over Ethernet compatible Plug Ethernet cable into the RJ45 connector labeled as ETH see figure below Figure 20 Connection of ethernet cable 16 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 2...

Страница 22: ...expansion port into the RJ45 connector labeled as PORT1 see figure below Figure 21 PORT1 cable connection 5 7 5 PORT2 The PORT2 is equipped on customer s request with one of the offered expansion ports RS232 RS485 RS422 MBUS SDH SWITCH together with PORT1 WIFI WMBUS Description and examples of expansion ports connection can be found in user s guide for corresponding expansion port 17 23 05 16 LUCO...

Страница 23: ...al negative pole Input Output 3 USB data USB data signal positive pole Input Output 4 GND Negative pole of DC supply voltage Table 8 Connection of USB connector Figure 23 USB connector 5 7 7 I O Port Panel socket 3 pin Pin Signal mark Description Data flow direction 1 BIN0 Binary input Input 2 GND Signal ground 3 OUT0 Binary output Output Table 9 Connection of I O port 18 23 05 16 LUCOM GmbH Ansba...

Страница 24: ...ent supplied by the binary input is 3 mA Connect I O cable into the I O connector on the front panel of the router and tighten locking screws see figure below Figure 25 Connection of I O cable Example of a circuit describing connection of binary input and output to the router Figure 26 Connection of input and output to the router 19 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 ...

Страница 25: ...ation of the router see Configuration manual for v2 routers because reset of the router sets the configuration to the default state It is important to distinguish between reset and reboot the router Action Router behavior Invoking events Reboot Turn off and then turn on router Disconnect and connect the power Press the Reboot button in the web configuration Reset Restore default configuration and ...

Страница 26: ...n it is necessary to connect all components which are required to run your applications The router can not operate without connected power supply Figure 28 Router connection 21 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 Fax 09127 59 460 20 www lucom de www lucom de info lucom de ...

Страница 27: ... consumption can be increased if some expansion port is eqquipped For correct operation it is necessary that the power source is able to supply a peak current of 0 5 A 6 3 Configuration 6 3 1 Configuration over web browser For status monitoring configuration and administration of the router is available a web interface which can be accessed by entering the IP address of the router into the web bro...

Страница 28: ...d administration of the router can be also used Telnet After entering the IP address of the router you will be allowed to configure the router using commands The default IP address of the router is 192 168 1 1 Configuration may be performed only by the user root with default password root A detailed description of the router settings via the Telnet can be found in the document Con figuration manua...

Страница 29: ...50 g XR5i v2 SL 280 g User interface ETH USB PORT1 PORT2 Ethernet 10 100 Mbit s USB 2 0 Ethernet 10 100 Mbit s On customer s request Table 11 Basic parameters 7 2 Standards and regulations The router complies with the following standards and regulations Standards and regulations EMC ETSI EN 301 489 1 v1 9 2 Safety EN 60950 1 2006 A11 2009 A1 2010 A12 2011 A2 2013 Table 12 Standards and regulations...

Страница 30: ... 7 4 Technical parameters of I O port Binary input and output Input Output Binary input Binary output Reed contact with trigger level 1 3 up to 1 4 V 100 mA max 30 V Table 14 Technical parameters of I O port 7 5 Technical parameters of expansion port Technical parameters of expansion ports are provided in separate manuals 25 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 460 10 F...

Страница 31: ...manual Expansion port CNT 7 Conel User s manual Expansion port ETH 8 Conel User s manual Expansion port SWITCH 9 Conel User s manual Expansion port WIFI 10 Conel User s manual Expansion port WMBUS 11 Conel User s manual Expansion port SD 12 Conel Application note Expansion port mounting 13 Conel Application note Programmer guide 26 23 05 16 LUCOM GmbH Ansbacher Str 2a 90513 Zirndorf Tel 09127 59 4...

Страница 32: ...a Keep the antenna as far as possible from the power supply I can t access the Web server over NAT The remote HTTP access of the router has to be disabled the default server ad dress has to be your web server and the gateway of the web server has to be the IP of the router Ethernet connection fails or isn t establishing It is possible to turn auto negotiation off and set a rate and duplex manually...

Страница 33: ...ed L2TP or IPSec isn t establishing Check the system log for error messages I switched the router to offline mode by SMS message but the router is in online mode after restart SMS messages do not change the router configuration They remain in effect only until the router is restarted FTP doesn t function Router doesn t support active FTP mode It supports passive mode only 28 23 05 16 LUCOM GmbH An...

Страница 34: ...hat the router narrated in this user s guide fits all basic demands of directive 1999 5 EC R TTE Router fits values of coefficient SAR defined by association ICNIRP and values of About protection of health before non ionized radiation Declaration of Conformity was issued and it is possible to find it on the Conel website http www conel com download 1 or at producer 1 Please use the following login...

Отзывы: