Trouble Shooting
Fault
Fault Analysis
Solution
No fog - switch at the front of the unit
does not light up
No power supply
Check the power supply - Is the transformer
connected to a working socket? Are both plugs
connected correctly? If the unit still does not
work, contact your dealer.
No fog - switch at the front of the unit
lights red
Unit has power but not switched on
1x Press the start button, the switch lights green
and the device works.
No fog- switch at the front of unit lights
green
Empty water Container
Fill up with water
Water drops on the membrane
Remove the nozzle and suck off the drop with a
tip of an absorbent material or simply wait a few
seconds until the water drop is atomized.
Cartridge has no contact to the membrane
Remove the cartridge holder and place the
cartridge correctly, if necessary push it slightly
upwards so that it stands out a little longer.
Cartridge has frayed too much and therefore has
no contact
Replace cartridge with a new one
Weak fog performance
Dirty or stale water
Clean water tank and replace water
Cartridge has only bad contact with the
membrane
Check positioning and change cartridge if
necessary
Dirty, limy or damaged membrane
Replace membrane. Please read the operating
instructions!
Unusual noises
Very little water in the container
Fill up with water
Water drops on the membrane
Remove the nozzle and suck off the drop with a
tip of an absorbent material.
Cartridge has only bad contact with the
membrane
Check seat and replace cartridge if necessary
Dirty, limy or damaged membrane
Replace membrane. Please read the operating
instructions!
Safety notices
• Do not switch on the humidifier if it does not contain water.
• Transformer, power cable, switch and the connectors have to be checked regularly for
damages. In case of damage the humidifier has to be taken from operation immediate
-
ly or rather may not be put into operation.
• The cable between the transformer and the device should always be installed with
a U-bend (cable hanging down) so that no water drops run along the cable into the
transformer.
• Before commissioning a device, it must generally be checked whether this device is
basically suitable for the application for which it is to be used!
• In case of doubt consultation of experts or the manufacturers of the employed devices
is required!
• Use in terrariums or outdoors is not permitted.
• Disconnect the humidifier from the power supply when removing the water tank or
moving the unit.
• The device may only be used with the transformer supplied by the manufacturer.
• Keep the device as far away from electromagnetic fields as possible.
• Do not disassemble the device or make any technical changes.
• Do not operate the device in locations with high humidity.
List of offered replacement articles
Head with membrane
SN-3
62373
Cartridge holder including cartridge
SN-4
62374
Hose
SFM-2
62308
Technical Specifications
Humidification capacity:
30 ml/h
Water tank capacity:
max. 360 ml
Input voltage:
AC 100 – 240V 50/60Hz
Supply voltage:
DC 5V
Power consumption:
1,5 W +- 0,5W